emi filter model hh-1199-6

RO
EMI FILTER
MODEL HH-1199-6
250 VAC, 6A
Data Sheet
LOAD
LINE
RO ASSOCIATES
C3
L1
The HH-1199-6 filter was designed especially for the
UNIVERTER™ Series of AC-DC converters with power factor
Correction. This filter works well for systems with
requirements to meet the new European EN55022 emissions
specification or for systems required to meet the FCC
conducted emissions standards.
C5
R1
C2
C1
L2
L3
C1=1.0µF
L1,2=190µH
C4
C2,7=.33µF
L3,4=2x5.7mH
C7
L4
C6
C3-6=.01µF
R1=235kΩ
Specifications:
Operating Voltage
Operating Current (max)
Frequency
Temperature Range (storage)
Temperature Range (operating)
Diel. withstanding voltage (ph - case)
Diel. withstanding voltage (ph - ph)
Leakage current at 250 VAC, 60 Hz
Discharge voltage after 60 seconds
Astrodyne Corporation
35 Hampden Rd
125/ 250 VAC
6.0 A
50/ 60 Hz
-40 to 85 °C
-20 to 50 °C
1500 VAC
1500 VDC
2.5 mA max
34 V max
www.astrodyne.com
www.roassoc.com
Tel: (800) 823-8082
Fax: (508) 339-0375
[email protected]