LL-1355-13BHT The LL-1355-13BHT filter has been designed to operate with two VICOR Harmonic Attenuator Modules (HAM). This filter was specifically designed to allow the Vicor HAM and associated power converters to meet Mil-Std461C or Mil-Std-461D, E or F This version of the filter is configured for those applications where a chassis mount for the filter is preferred. Order P/N: LL-1355-13BHT Operating Voltage = ___________________ 85 to 250 V Operating Current = ______________________ 13 Amp Operating Frequency = __________________50/400 Hz Operating Temperature, High = ________________70ºC Operating Temperature, Low = _______________ -40ºC INSERTION LOSS vs. FREQUENCY Diel. Withstanding (line - case) = ___________1500 Vac Diel. Withstanding (line - line) = ____________1500 Vdc Leakage Current = ___________2.5 ma @ 220 V, 60 Hz Max Residual Voltage after 1 sec = __________34 Volts Calculated MTBF = ________2,142,107 Hrs @ 30°C GB USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884 EUR JMK Inc Glasgow G13 1DN Scotland UK