LL-1355-13BHT

LL-1355-13BHT
The LL-1355-13BHT filter has been designed to operate
with two VICOR Harmonic Attenuator Modules (HAM).
This filter was specifically designed to allow the Vicor
HAM and associated power converters to meet Mil-Std461C or Mil-Std-461D, E or F
This version of the filter is configured for those
applications where a chassis mount for the filter is
preferred.
Order P/N:
LL-1355-13BHT
Operating Voltage = ___________________ 85 to 250 V
Operating Current = ______________________ 13 Amp
Operating Frequency = __________________50/400 Hz
Operating Temperature, High = ________________70ºC
Operating Temperature, Low = _______________ -40ºC
INSERTION LOSS vs. FREQUENCY
Diel. Withstanding (line - case) = ___________1500 Vac
Diel. Withstanding (line - line) = ____________1500 Vdc
Leakage Current = ___________2.5 ma @ 220 V, 60 Hz
Max Residual Voltage after 1 sec = __________34 Volts
Calculated MTBF = ________2,142,107 Hrs @ 30°C GB
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884
EUR
JMK Inc Glasgow G13 1DN Scotland UK