FF-2142-6.3

FF-2142-6.3
This filter has been designed to operate with the VICOR
(HAM) Harmonic Attenuator Module.
The combination is designed to meet the conducted
emissions requirements of EN 55015.
The filter will also function very well with most other fixed
frequency switching power supplies.
Order P/N:
FF-2142-6.3
Operating Voltage = _________________ DC—250 Vac
Operating Current (Max)= ____________________ 6.3A
INSERTION LOSS vs. FREQUENCY
Frequency = _________________ 50/60 HZ @ 250 Vac
= ___________________ 400 Hz @ 120 Vac
Temp. Range (Storage) = ______________-25°—100°C
Temp. Range (Operating) (-13)@ 13.0 A = _ -25°—60ºC
(See temp graph)
Diel. Withstanding (Ph—Case) = __ 1500 Vac; For 1 Min
Diel. Withstanding (Ph—Ph) = ____ 1500 Vdc; For 1 Min
Leakage Current @ 250 Vac, 60 HZ = ____ 0.5 MA max.
Discharge Voltage after 3 sec = ___________ 20 V max.
Weight = _______________________________ 2.5 Lbs
DCR = _________________________0.85 Ohm; ea. leg
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884
EUR
JMK Inc Glasgow G13 1DN Scotland UK
FF-2142-6.3
Conducted Emission Test Results:
Specification EN55015
Input Voltage: 220 V
Frequency: 60 Hz
Input Current: 6.3 amp
Output Power: ~600 Watt
Temperature: 23°C
Comments:
The “worst case” emissions occurred full load. The results for both the Primary line and the Neutral line were similar.
OPERATING CURRENT vs. AMBIENT TEMPERATURE