JMK, Inc ZA-1536-10 The ZA-1536-10 filter has been designed to operate with the Mission power solutions “BADGER” power supply. The combination will meet the requirements of Mil-Std-461D or Mil-Std-461E. Operating voltage (AC) = 115/120/200/220 V~ Operating Voltage (DC) = 100—375 Vdc Operating current = 10 Amp Operating frequency = DC—400 Hz Operating temperature = (-55)—50C Diel. withstanding (line - case) = 1500 Vac Diel. withstanding (line - line) = 1500 Vdc Leakage current = 0.4 ma Max. at 115 Vac, 400 Hz Max residual voltage after 1 sec. = 34 Volts Calculated MTBF = 1,874,769 hours 30oC GB Order P/N: ZA-1536-10 1 L 2 N 3 G 90 INSERTION LOSS (db) 80 70 DM 60 50 40 30 20 CM 10 0 .01 .04 .02 .1 .07 .4 .2 1 .7 4 2 10 7 40 20 FREQUENCY (MEGAHERTZ) 0.25 TAB TERM (3x) 6-32 INSERT (4PL) N G L 3.030 3.88 2.430 0.60 0.29 0.90 0.25 1.745 0.25 2.000 2.24 2.50 0.25 2.00 0.25 1.75 1 2 3 6-32 INSERT (4PL) USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884 EUR JMK Inc Glasgow G13 1DN Scotland UK 100 70