FEATURES
DESCRIPTION
83 MHz Data Rate
12-bit Data or Coefficients (Expandable to 24-bit)
32-Tap FIR Filter, Cascadable for
More Filter Taps
Over 49 K-bits of on-board Memory
LF InterfaceTM Allows All 256 Coefficient Sets to be Updated Within
Vertical Blanking
Various Operating Modes: Dual
Filter, Single Filter, Double Wide
Data or Coefficient, Matrix Multiplication, and Accumulator Access.
Selectable 16-bit Data Output with
User-Defined Rounding and Limiting
Supports Interleaved Data Streams
Supports Decimation up to 16:1 for
Increasing Number of Filter Taps
3.3 Volt Supply
144 Lead PQFP
The LF3320 filters digital images in
the horizontal dimension at real-time
video rates. The input and coefficient
data are both 12 bits and in two’s complement format. The output is also in
two’s complement format and may be
rounded to 16 bits.
The LF3320 is designed to take advantage of symmetric coefficient sets.
When symmetric coefficient sets are
used, the device can be configured as
a single 32-tap FIR filter or as two separate 16-tap FIR filters.
Interleave/Decimation Registers (I/D
Registers) allow interleaved data to be
fed directly into the device and filtered without separating the data into
individual data streams.
The LF3320 can handle a maximum of
sixteen data sets interleaved together.
The I/D Registers and on-chip accumulators facilitate using decimation
to increase the number of filter taps.
Decimation of up to 16:1 is supported.
The LF3320 contains enough on-board
memory to store 256 coefficient sets.
Two separate LF InterfacesTM allow
all 256 coefficient sets to be updated
within vertical blanking.
When asymmetric coefficient sets are
used, the device can be configured
as a single 16-tap FIR filter or as
two separate 8-tap FIR filters. MulNOTE: loading registers via the LF
tiple LF3320s can be cascaded to create interface must not exceed 90MHz. The
larger filters.
PAUSE pin must be used to throttle
back the LF interface at clock speeds
above 90MHz.
LF3320 BLOCK DIAGRAM
ROUT11-0
DIN11-0
CAA7-0
12
12
INTERLEAVE / DECIMATION
REGISTERS
12
12
8
8
CENA
CFA11-0
PAUSEA
LDA
RIN11-0
COUT11-0
CAB7-0
CENB
12
256
COEFFICIENT
SET
STORAGE
16-TAP
FILTER A
16-TAP
FILTER B
256
COEFFICIENT
SET
STORAGE
12
CFB11-0
PAUSEB
LDB
ROUND
SELECT
LIMIT
CIRCUITRY
CLK
OED
16
DOUT15-0
Video Imaging Products
2-1
6/22/2007–LDS.3320-R
2-2
FILTER A
LF
INTERFACE
Coef Bank 7
Coef Bank 6
Coef Bank 5
CLK
SHENB
SHENA
RSLA3-0
TXFRB
TXFRA
ACCA
12
CENA
Coef Bank 4
4
A
ALU
B
A
ALU
B
A
ALU
B
B
A
ALU
B
A
ALU
B
A
ALU
B
A
ALU
B
32
27
13
13
32
13
"0"
13
27
13
13
ALU
B
25
25
25
25
ACCM A
25
25
25
25
25
DOUT15-0
16
RSLB OUT15-0
16
ACCM B
25
16
SCALE
25
ROUND
SELECT
LIMIT
FILTER B
25
ROUND
SELECT
LIMIT
FILTER A
32
CONFIGURATION AND
CONTROL REGISTERS
25
25
25
25
12
13
A
12
32
ALU
12
"0"
A
12
27
B
12
27
ALU
12
13
A
12
13
B
12
13
ALU
12
13
A
12
B
12
13
ALU
12
13
A
12
1-16
12
13
B
1-16
12
13
ALU
1-16
A
1-16
1-16
Coef Bank 3
B
1-16
1-16
Coef Bank 2
ALU
1-16
1-16
Coef Bank 1
A
1-16
1-16
B
1-16
1-16
ALU
1-16
1-16
A
1-16
12
B
S E O I
Coef Bank 0
ALU
1-16
1-16
13
A
1-16
8
12
DATA
REVERSAL
1-16
FILTER B I/D REGISTERS
1-16
1-16
FILTER A I/D REGISTERS
1-16
RSLB OUT15-12
1-16
CAA7-0
DIN11-0
ROUT11-4
1-16
4
8
12
RSLB
OUT11-0
ROUT3-0
1-16
1-16
CFA11-0
1-16
1-16
PAUSEA
1-16
FILTER B
LF
INTERFACE
Coef Bank 8
Coef Bank 9
Coef Bank 10
Coef Bank 11
Coef Bank 12
Coef Bank 13
Coef Bank 14
Coef Bank 15
CFB11-0
DATA
REVERSAL
LDA
R E O I
LDB
8
4
CAB7-0
12
12
OED
RSLB3-0
ACCB
CENB
COUT11-0
OEC
RIN11-0
DEVICES INCORPORATED
PAUSEB
OEC
LF3320
Horizontal Digital Image Filter
FIGURE 1. LF3320 FUNCTIONAL BLOCK DIAGRAM
Video Imaging Products
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
SIGNAL DEFINITIONS
Horizontal Digital Image Filter
FIGURE 2. INPUT FORMATS
Power
VCC and GND
+3.3 V power supply. All pins must
be connected.
Input Data
11 10 9
–211 210 29
Coefficient Data
2 1 0
22 21 20
(Sign)
11 10 9
–20 2–1 2–2
(Sign)
2 1 0
2–9 2–10 2–11
Clock
CLK — Master Clock
FIGURE 3. ACCUMULATOR OUTPUT FORMATS
The rising edge of CLK strobes all
enabled registers.
Inputs
DIN11-0 — Data Input
DIN11-0 is the 12-bit data input port to
Filter A. In Dual Filter Mode, DIN11-0
can also be the 12-bit input port to
Filter B. Data is latched on the rising
edge of CLK.
Accumulator A Output
31 30 29
–220 219 218
2 1 0
2–9 2–10 2–11
(Sign)
S15 S14 S13
00000
F15 F14 F13
RIN11-0 — Reverse Cascade Input
00001
F16 F15 F14
In Single Filter Mode, RIN11-0 is the
12-bit reverse cascade input port. This
port is connected to ROUT11-0 of
another LF3320. In Dual Filter Mode,
RIN11-0 can be the 12-bit input port to
Filter B. Data is latched on the rising
edge of CLK.
00010
F17 F16 F15
01110
F29 F28 F27
01111
F30 F29 F28
CFA11-0 — Coefficient A Input
10000
F31 F30 F29
CAA7-0 — Coefficient Address A
CAA7-0 determines which row of data
in coefficient banks 0 through 7 is fed
to the multipliers. CAA7-0 is latched
into Coefficient Address Register A on
the rising edge of CLK when CENA is
LOW.
31 30 29
–220 219 218
(Sign)
TABLE 1. OUTPUT FORMATS
SLCT4-0
CFA11-0 is used to load data into
the Filter A coefficient banks (banks
0 through 7) and the configuration/
control registers. Data present on
CFA11-0 is latched into the Filter A LF
InterfaceTM on the rising edge of CLK
when LDA is LOW (see the LF InterfaceTM section for a full discussion).
Accumulator B Output
·
·
·
·
·
·
·
·
·
·
·
·
···
···
···
···
···
···
···
S8
S7
F8
F7
F9
F8
F10
F9
·
·
·
·
·
·
F22 F21
F23 F22
F24 F23
2 1 0
2–9 2–10 2–11
···
···
···
···
S2
S1
S0
F2
F1
F0
F3
F2
F1
F4
F3
F2
···
···
···
F16 F15 F14
·
·
·
·
·
·
·
·
·
F17 F16 F15
F18 F17 F16
CFB11-0 — Coefficient B Input
LOW.
CFB11-0 is used to load data into
the Filter B coefficient banks (banks
8 through 15) and the configuration/
control registers. Data present on
CFB11-0 is latched into the Filter B LF
InterfaceTM on the rising edge of CLK
when LDB is LOW (see the LF InterfaceTM section for a full discussion).
Outputs
CAB7-0 — Coefficient Address B
COUT11-0 — Cascade Output
CAB7-0 determines which row of data
in coefficient banks 8 through 15 is fed
to the multipliers. CAB7-0 is latched
into Coefficient Address Register B on
the rising edge of CLK when CENB is
In Single Filter Mode, COUT11-0 is a
12-bit registered cascade output port.
COUT11-0 should be connected to
DIN11-0 of another LF3320. In Dual
Filter Mode, COUT11-0 is a 12-bit
DOUT15-0 — Data Output
DOUT15-0 is the 16-bit registered data
output port for the overall filter (Single
Filter Mode) or Filter A (Dual Filter
Mode).
Video Imaging Products
2-3
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
registered output port for the lower
twelve bits of the 16-bit Filter B
output.
ROUT11-0 — Reverse Cascade Output
In Single Filter Mode, ROUT11-0 is
a 12-bit registered cascade output
port. ROUT11-0 on one device should
be connected to RIN11-0 of another
LF3320. In Dual Filter Mode, ROUT3-0
is a 4-bit registered output port for
the upper four bits of the 16-bit Filter
B output. In this mode, ROUT11-4 is
disabled.
Controls
LDA — Coefficient A Load
When LDA is LOW, data on CFA11-0
is latched into the Filter A LF InterfaceTM on the rising edge of CLK.
When LDA is HIGH, data is not
loaded into the Filter A LF InterfaceTM.
When enabling the LF InterfaceTM for
data input, a HIGH to LOW transition
of LDA is required in order for the
input circuitry to function properly.
Therefore, LDA must be set HIGH
immediately after power up to ensure
proper operation of the input circuitry
(see the LF InterfaceTM section for a
full discussion).
CENA — Coefficient Address Enable A
When CENA is LOW, data on CAA7-0
is latched into Coefficient Address
Register A on the rising edge of
CLK. When CENA is HIGH, data on
CAA7-0 is not latched and the register’s contents will not be changed.
Horizontal Digital Image Filter
LDB must be set HIGH immediately
after power up to ensure proper operation of the input circuitry (see the
LF InterfaceTM section for a full discussion).
CENB — Coefficient Address Enable B
When CENB is LOW, data on CAB7-0
is latched into Coefficient Address
Register B on the rising edge of CLK.
When CENB is HIGH, data on CAB7-0
is not latched and the register’s contents will not be changed.
TXFRA — Filter A LIFO Transfer
Control
TXFRA is used to change which LIFO
in the data reversal circuitry sends
data to the reverse data path and
which LIFO receives data from the
forward data path in Filter A. When
TXFRA goes LOW, the LIFO sending
data to the reverse data path becomes
the LIFO receiving data from the forward data path, and the LIFO receiving data from the forward data path
becomes the LIFO sending data to
the reverse data path. The device
must see a HIGH to LOW transition
of TXFRA in order to switch LIFOs.
TXFRA is latched on the rising edge
of CLK.
TXFRB — Filter B LIFO Transfer
Control
TXFRB is used to change which LIFO
in the data reversal circuitry sends
data to the reverse data path and
which LIFO receives data from the
forward data path in Filter B. When
TXFRB goes LOW, the LIFO sending
LDB — Coefficient B Load
data to the reverse data path becomes
When LDB is LOW, data on CFB11-0 is the LIFO receiving data from the forlatched into the Filter B LF InterfaceTM ward data path, and the LIFO receivon the rising edge of CLK. When LDB ing data from the forward data path
becomes the LIFO sending data to
is HIGH, data is not loaded into the
Filter B LF InterfaceTM. When enabling the reverse data path. The device
must see a HIGH to LOW transition
the LF InterfaceTM for data input, a
of TXFRB in order to switch LIFOs.
HIGH to LOW transition of LDB is
TXFRB is latched on the rising edge of
required in order for the input circuitry to function properly. Therefore, CLK.
ACCA — Accumulator A Control
When ACCA is HIGH, Accumulator
A is enabled for accumulation and the
Accumulator A Output Register is disabled for loading. When ACCA is
LOW, no accumulation is performed
and the Accumulator A Output Register is enabled for loading. ACCA is
latched on the rising edge of CLK.
ACCB — Accumulator B Control
When ACCB is HIGH, Accumulator B
is enabled for accumulation and the
Accumulator B Output Register is disabled for loading. When ACCB is
LOW, no accumulation is performed
and the Accumulator B Output Register is enabled for loading. ACCB is
latched on the rising edge of CLK.
SHENA — Filter A Shift Enable
In Dual Filter Mode, SHENA enables
or disables the loading of data into the
Input (DIN11-0) and Filter A I/D Registers. When SHENA is LOW, data
is latched into the Input/Cascade Registers and shifted through the I/D
Registers on the rising edge of CLK.
When SHENA is HIGH, data can
not be loaded into the Input/Cascade
Registers or shifted through the I/D
Registers and their contents will not
be changed.
In Single Filter Mode, SHENA also
enables or disables the loading of
data into the Reverse Cascade Input
(RIN11-0), Cascade Output
(COUT11-0), Reverse Cascade Output
(ROUT11-0) and Filter B I/D Registers.
It is important to note that in Single
Filter Mode, both SHENA and SHENB
should be connected together. Both
must be active to enable data loading
in Single Filter Mode. SHENA is
latched on the rising edge of CLK.
SHENB — Filter B Shift Enable
In Dual Filter Mode, SHENB enables
or disables the loading of data into
the Reverse Cascade Input (RIN11-0),
Video Imaging Products
2-4
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
Cascade Output (COUT11-0), Reverse
Cascade Output (ROUT3-0) and Filter
B I/D Registers. When SHENB is
LOW, data is latched into the Cascade
Registers and shifted through the I/D
Registers on the rising edge of CLK.
When SHENB is HIGH, data can
not be loaded into the Cascade Registers or shifted through the I/D Registers and their contents will not be
changed.
HIGH, DOUT15-0 is placed in a highimpedance state.
In Single Filter Mode, SHENB also
enables or disables the loading of data
into the Input (DIN11-0), Reverse Cascade Output (ROUT11-0) and Filter
A I/D Registers. It is important to
note that in Single Filter Mode, both
SHENA and SHENB should be connected together. Both must be active
to enable data loading in Single Filter
Mode. SHENB is latched on the rising
edge of CLK.
When PAUSEA is HIGH, the Filter
A LF InterfaceTM loading sequence is
halted until PAUSEA is returned to
a LOW state. This effectively allows
the user to load coefficients and control registers at a slower rate than the
master clock (see the LF InterfaceTM
section for a full discussion).
OEC — COUT/ROUT Output Enable
When OEC is LOW, COUT11-0 and
ROUT3-0 are enabled for output.
When OEC is HIGH, COUT11-0 and
ROUT3-0 are placed in a high-impedance state.
PAUSEA — LF Interface
TM
PAUSEB — LF InterfaceTM Pause
When PAUSEB is HIGH, the Filter B
Pause
FIGURE 4. SINGLE FILTER MODE
12
ROUT11-0
12
12
DIN11-0
I/D
REGISTERS
I/D
REGISTERS
FILTER
A
FILTER
B
RIN11-0
12
COUT11-0
RSLA3-0 — Filter A Round/Select/Limit
Control
RSLA3-0 determines which of the
sixteen user-programmable Round/
Select/Limit registers (RSL registers)
are used in the Filter A RSL circuitry.
A value of 0 on RSLA3-0 selects RSL
register 0. A value of 1 selects RSL
register 1 and so on. RSLA3-0 is
latched on the rising edge of CLK (see
the round, select, and limit sections for
a complete discussion).
RSL
CIRCUIT
16
DOUT15-0
FIGURE 5. DUAL FILTER MODE
12
RSLB3-0 — Filter B Round/Select/Limit
Control
RSLB3-0 determines which of the sixteen user-programmable RSL registers
are used in the Filter B RSL circuitry.
A value of 0 on RSLB3-0 selects RSL
register 0. A value of 1 selects RSL
register 1 and so on. RSLB3-0 is
latched on the rising edge of CLK (see
the round, select, and limit sections for
a complete discussion).
OED — DOUT Output Enable
When OED is LOW, DOUT15-0 is
enabled for output. When OED is
DIN11-0
12
I/D
REGISTERS
I/D
REGISTERS
FILTER
A
FILTER
B
R.S.L.
CIRCUIT
R.S.L.
CIRCUIT
16
DOUT15-0
RIN11-0
16
ROUT3-0 / COUT11-0
Video Imaging Products
2-5
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
LF InterfaceTM loading sequence is
halted until PAUSEB is returned to
a LOW state. This effectively allows
the user to load coefficients and control registers at a slower rate than the
master clock (see the LF InterfaceTM
section for a full discussion).
OPERATIONAL MODES
Single Filter Mode
In this mode, the device operates as a
single FIR filter (see Figure 4). It can
be configured to have as many as 32
taps if symmetric coefficient sets are
used. If asymmetric coefficient sets
are used, the device can be configured
to have as many as 16 taps. Cascade
ports are provided to facilitate cascading multiple devices to increase the
number of filter taps. Bit 1 in Configuration Register 5 determines the filter
mode. In Single Filter Mode, DIN11-0
is the data input for the filter and
DOUT15-0 is the data output for the
filter.
In this mode, the device operates as
two separate FIR filters (see Figure 5).
Each filter can be configured to have
as many as 16 taps if symmetric coefficient sets are used. If asymmetric
coefficient sets are used, each filter can
be configured to have as many as 8
taps. In Dual Filter Mode, DIN11-0 is
the data input for Filter A. Either
RIN11-0 or DIN11-0 can be the data
input for Filter B. The Filter B input
is determined by Bit 2 in Configuration Register 5. DOUT15-0 is the
data output for Filter A. COUT11-0
and ROUT3-0 together form the data
output for Filter B. COUT11-0 is
the twelve least significant bits and
ROUT3-0 is the four most significant
bits of the 16-bit Filter B output.
filter mode, the LF3320 can process
two matrix-vector multipliers simultaneously (i.e. [8x8][8x1]). In the
single filter mode, the LF3320 can
process a single matrix-vector multiply (i.e. [16x16][16x1]). This mode of
operation allows the user to organize
data values (e.g. pixels) into an array
(e.g. blocks). This function is useful
for any application requiring the operation of matrix multiplication; a function that is used when generating
Discrete Cosine Transform coefficients
(DCT) for the purpose of further processing.
When configuring the LF3320 for an
[8x8][8x1] matrix-vector operation, the
coefficient banks will require 8 coefficient sets to be loaded into the coefficient memory banks; each coefficient
set will have 8, 12-bit coefficients. The
Matrix-vector Multiply Mode
input data, [8x1] column-vector, will
In this mode, the LF3320 can be conbe loaded through DIN11-0 for Filter
figured to multiply a square matrix of A; either RIN11-0 or DIN11-0 can
maximum size N (N = 8 or 16), multi- be the data input for Filter B.
plied by a matrix-vector of maximum
Conversely, when configured for a
size [8,1] or [16,1]. The mathematical
[16x16][16x1] matrix-vector operation,
representation for this operation is in
Dual Filter Mode
the coefficient banks will require 16
Figure 7. When configured in the dual coefficient sets to be loaded into
the coefficient memory banks; each
FIGURE 6. MATRIX-VECTOR MULTIPLY MODE
coefficient set will have 16, 12-bit
coefficients. The input data, [16x1]
N
column-vector, will be loaded through
DIN11-0.
DIN11-0
RIN11-0
12
0
A
ALU
B
0
A
ALU
0
0
B
A
ALU
B
A
ALU
B
To configure the LF3320 for
FIGURE 7. MATRIX EQUATION
TXFRA
TXFRB
COEF (N-1)
N
COEF 2
COEF 1
COEF 0
C = COEFFICIENTS
D = DATA INPUT
R = DATA OUTPUT
12
12
12
C00 C01 C02
R0
C10 C11 C12
R1
R2 = C20 C21 C22
C0j
C1j
C2j
D0
D1
D2
Ci0 Ci1 Ci2
Cij
Di
Ri
12
(N-1)
Ri
Dual Filter Mode, N=8
Single FIlter Mode, N=16
=
Cij Di
i=0
For j=0,1,2,...,(N-1)
N=8 or 16
32
Video Imaging Products
2-6
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
matrix-vector multiplication, bit 4 of
Configuration Register 5 must be set
to 1 (Table 7). The configuration for
single filter mode or dual filter mode
will still apply. Writing 012H or
016H to Configuration Register 5 will
configure the device for dual filter
mode, [8x8][8x1] matrix-vector multiplication. Subsequently, writing 014H
to Configuration Register 5 will configure the device for single filter
mode, [16x16][16x1] matrix-vector
multiplication.
Some functions of the LF3320 must
be disabled when configured for
matrix-vector multiplication. This will
apply to both the single filter mode
and the dual filter mode; these functions are data reversal and interleave/
decimation. The LF3320 can be cascaded to realize larger matrices.
Data reversal can be disabled by setting bit 6, of Configuration Register 1
(Filter A) and Configuration Register 3
(Filter B), both to 1. The Odd-Tap,
interleave mode will need to be disabled. Writing a 0 to bit 0 of Configuration Register 1 and Configuration Register 3 will disable the odd-tap
interleave mode for Filter A and
Filter B. When data is not being inter-
leaved or decimated, the I/D Register
length should be set to a length of one
(Table 3 and Table 5). Therefore, writing 040H to Configuration Register 1
and 3 will disable the data reversal
and set the corresponding inherent
characteristics for the desired matrix
function.
The Filter A ALU and Filter B ALU
are to be configured for A+B (Table 2
and Table 4); so that condition A+0 is
satisfied. To accomplish this, bit 0
is to be reset to 0, bit 1 is to be set
to 1, and bit 2 is to be reset to 0. Writing 002H to Configuration Register 0
(Filter A) and Configuration Register
2 (Filter B) will set the corresponding
registers to satisfy the A+0 condition.
The timing diagrams in Figure 8 and 9
will assume that the Configuration
Registers, the coefficient sets, and the
first set of data values (data set)
have been loaded. Loading input
data for an [8x8][8x1] matrix operation
requires 9 clock cycles and loading
input data for a [16x16][16x1] matrix
operation requires 17 clock cycles.
When configured for an [8x8][8x1]
matrix-vector operation, 8 data values
are required for loading. When
configured for a [16x16][16x1]
matrix-vector operation, 16 data
values are required for loading. Each
data value is fed through the I/D Registers, using the corresponding input.
Once the final data value, of the data
set, has been loaded TXFRA/TXFRB
should be brought LOW for one clock
cycle to complete the loading. Once
this occurs, the data set is then bank
loaded into the respective registers
ready to begin the matrix-vector multiplication operation. The current data
set will not change until TXFRA/
TXFRB is brought LOW again. To satisfy the matrix equation (see Figure 7),
the current data set is held for
the duration of the required matrix
dimension while cycling through each
coefficient set (CENA/CENB must
be held LOW). During this time
new data values can be loaded serially, ready for the next activation of
TXFRA/TXFRB. To insure the correct
evaluation of the matrix-vector multiplication equation, it is imperative that
the coefficient values are paired with
their corresponding data values.
For the [8x8][8x1] matrix-vector configuration (dual filter mode), the first
result will appear 19 clock cycles from
the first data input, DIN15-0 (Filter A)
FIGURE 8. DUAL FILTER, MATRIX MULTIPLY TIMING SEQUENCE
Data Set 1 with 8 Coefficient Sets
1
2
3
8*
Data Set 2 with 8 Coefficient Sets
9
10**
11
17***
18
CLK
DIN11-0
RIN11-0
DATA SET 1
DATA SET 0
CAA7-0
CAB7-0
CF00
CF01
CF02
CF07
CF10
CF11
CF12
CF17
CF20
CF21
TXFRA/ TXFRB
DOUT15-0
ROUT3-0/COUT15-0
OUT0
OUT1
OUT7
OUT0
OUT1
CENA / CENB
SHENA / SHENB
*
**
***
8 Clocks - End of First Data/Coefficient Set
10 Clocks - First Output of First Data/Coefficient Set
17 Clocks - Final Output of First Data/Coefficient Set
Video Imaging Products
2-7
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
FIGURE 9. SINGLE FILTER, MATRIX MULTIPLY TIMING SEQUENCE
1 Data Set with 16 Coefficient Sets
1
2
11*
3
12
13
14
15
CF0D
CF0E
16**
26***
17
CLK
DIN11-0
RIN11-0
DATA SET 0
DATA SET 0
CAA7-0
CAB7-0
CF00
CF01
CF02
CF0A
CF0B
CF0C
CF0F
CF10
TXFRA/ TXFRB
DOUT15-0
OUT0
OUT1
OUT2
OUT3
OUT4
OUT5
OUT15
OUT6
CENA / CENB
SHENA / SHENB
*
**
***
11 Clocks - First Output of First Data/Coefficient Set
16 Clocks - End of First Data/Coefficient Set
26 Clocks - Final Output From First Data/Coefficient Set
and RIN15-0 (Filter B); device latency
for the first result is 10 clock cycles
(10+9 = 19).
The result will appear at the corresponding filter output, DOUT15-0
(Filter A) and ROUT3-0/COUT11-0
(Filter B). For the [16x16][16x1]
matrix-vector configuration (single
filter mode), the first result will
appear 28 clock cycles from the first
data input, DIN15-0; device latency
for the first result is 11 clock cycles
(11+17 = 28). The result will appear
at the corresponding filter output,
DOUT15-0. Subsequently, for both
dual and single filter mode configurations, the sum of products will
continue to appear every clock cycle
thereafter until the matrix dimension
has been realized. The total pipeline
latency for a complete [8x8][8x1]
matrix-vector operation is 26 clock
cycles and the total pipeline latency
for a complete [16x16][16x1]
matrix-vector operation is 43 clock
cycles. Therefore, to process two
square matrices simultaneoulsy, of
size N=8, a total of 73 clock cycles
are all that is required. Similarly, to
process a single square matrix, of size
N=16, a total of 283 clock cycles are
FIGURE 10. DOUBLE WIDE DATA/COEFFICIENT MODE
DIN11-0
RIN11-0
12
I/D
REGISTERS
I/D
REGISTERS
FILTER
A
FILTER
B
12
SCALE
R.S.L.
CIRCUIT
16
DOUT15-0
required.
Once again, the timing diagrams (see
Figure 8 and 9) will assume that
the Configuration Registers, the coefficient sets, and the data values have
been loaded. The corresponding
timing diagram loading sequence
for the coefficient banks and
Configuration/Control registers are
included in the LF3320 data sheets
(Figure 11 and Figure 12 respectively).
Further reference to timing diagram
loading sequence for the RSL registers
are also included in the device data
sheet (Figure 15, Figure 14, and Figure
13). The Filter A and Filter B LF InterfaceTM are used to load data into the
Filter A and Filter B Configuration
Registers and coefficient banks.
The Matrix Multiplication Mode is
valid in the Double Wide Data/
Video Imaging Products
2-8
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Coefficient Mode. However, there are
some special considerations when this
mode is desired. The LF3320 must be
configured for single filter mode only,
for a maximum (8x8) matrix. The user
must disable the cascaded filter mode,
the accumulator access mode, and the
data reversal (see Table 7).
Horizontal Digital Image Filter
FIGURE 11. ACCUMULATOR ACCESS MODE
DIN11-0
12
I/D
REGISTERS
I/D
REGISTERS
FILTER
A
FILTER
B
R.S.L.
CIRCUIT
R.S.L.
CIRCUIT
16
16
12
RIN11-0
Double Wide Data/Coefficient Mode
The LF3320 is capable of supporting
24-bit data and 12-bit coefficients or
12-bit data and 24-bit coefficients.
When configured for this mode of
operation, the Filter B output is scaled
by 2-12 before adding it to the Filter
A output. This mode of operation is
only valid in single filter mode.
To configure the LF3320 for this mode,
bit 3 of Configuration Register 5 must
be set to 1; this will account for
the scaling function (Table 7). For
24-bit data, DIN11-0 becomes the MSB
(Filter A) and RIN11-0 becomes the
LSB (Filter B), bit 2 of Configuration
Register 5 must be set to 0. To
insure correct results, the coefficient
sets must be aligned appropriately;
that is to say, the coefficient set used
for the MSB must be the same for the
LSB. For 24-bit coefficients, the coefficient banks for Filter A will correspond to the coefficient MSB and the
coefficient banks for Filter B will correspond to the coefficient LSB; therefore, bit 2 must be set to 1.
Once again, to insure correct results,
the coefficient sets must be aligned
appropriately; that is to say, the MSB
coefficients must correspond to their
LSB coefficients. The output data will
appear at DOUT15-0; output appearing
at ROUT3-0/COUT11-0 will not be of
any value. Bit 1 is set to 0 (for
single filter mode) and bit 0 is set to 0
(cascade mode must
be disabled). Therefore, to realize
24-bit data/12-bit coefficients the user
must write 008H to Configuration
Register 5; conversely, for 12-bit data/
24-bit coefficients the user must write
00CH to Configuration Register 5.
DOUT15-0
The Double Wide Data/Coefficient
Mode is valid in the Matrix Multiplication Mode; however, special considerations must be observed when these
two modes are combined. The LF3320
must be configured for single filter
mode only, for a maximum (8x8)
matrix. In addition, the user must
disable the cascaded filter mode, the
accumulator access mode, and the
data reversal (Table 7). For additional
considerations, refer to the corresponding mode of operation section.
Accumulator Access Mode
Accumulator access allows the user to
accumulate the Filter A output with
the Filter B output. Therefore, this
mode is only valid when the device
has been configured for dual filter
operation. To configure the device for
this mode, bit 1 and bit 5 must be set
to 1; bit 5 is the corresponding accumulator access bit (Table 7). Writing
022H to Configuration Register 5 configures the device to accumulate the
Filter A output with the Filter B
output. All remaining Configuration
Registers, 0 through 4 inclusive, will
depend on specific application
requirements (see Tables 2 through
4). In this mode of operation,
ROUT3-0 / COUT11-0
the accumulated output is realized
at DOUT15-0. The output data at
ROUT15-0/COUT15-0 is the Filter B
output that is normally expected;
however, the accumulated output
data (DOUT15-0) will be delayed by
one clock cycle, compared to the Filter
B output data.
This type of operation is useful when
two filtered data streams (i.e. I+jQ)
need to be accumulated. Such is
the requirement to satisfy the equation, y(t) = cos(vt)+jsin(vt). The
complex data can be streamed and filtered using a respective ‘I’ filter and
‘Q’ filter. To convert the complex
result into a real result, as seen at
the LF3320 output, two multiplies and
one accumulation is required. The
cosine and sine functions are realized
through the coefficient sets; consequently, multiplied by the corresponding ‘I’ and ‘Q’ data streams. To
satisfy the remainder of the equation,
Filter A and Filter B must be accumulated.
As previously stated, this mode of
operation is only valid with the dual
filter mode configuration. All modes
of operation, that are valid in the
dual filter mode, are valid with the
accumulator access mode. For addi-
Video Imaging Products
2-9
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
FIGURE 12. SYMMETRIC COEFFICIENT SET EXAMPLES
8 7 6 5
8 7 6 5 4 3 2 1
7 6 5 4 3 2 1
Even-Tap, Even-Symmetric
Coefficient Set
4 3 2 1
Odd-Tap, Even-Symmetric
Coefficient Set
Even-Tap, Odd-Symmetric
Coefficient Set
FIGURE 13. I/D REGISTER DATA PATHS
ALU
1-16
1-16
1-16
1-16
1-16
1-16
Delay Stage N
A
A
B
DATA
REVERSAL
ALU
B
1-16
ALU
A
B
1-16
A
DATA
REVERSAL
1-16
ALU
B
1-16
DATA
REVERSAL
1-16
1-16
A
Delay Stage N 1
ALU
B
A
ALU
B
COEF 7
COEF 7
2
COEF 7
2
COEF 6
COEF 6
COEF 6
EVEN-TAP MODE
tional considerations, refer to the corresponding mode of operation section.
FUNCTIONAL DESCRIPTION
ALUs
The ALUs double the number of filter
taps available, when symmetric coefficient sets are used, by pre-adding data
values which are then multiplied by
a common coefficient (see Figure 12).
The ALUs can perform two operations: A+B and B–A. Bit 0 of Configuration Register 0 determines the operation of the ALUs in Filter A.
Bit 0 of Configuration Register 2 determines the operation of the ALUs
in Filter B. A+B is used with
even-symmetric coef-
ODD-TAP MODE
ficient sets. B–A is used with oddsymmetric coefficient sets.
Also, either the A or B operand may
be set to 0. Bits 1 and 2 of Configuration Register 0 and Configuration Register 2 control the ALU inputs in Filters A and B respectively. A+0 or B+0
are used with asymmetric coefficient
sets.
Interleave/Decimation Registers
The Interleave/Decimation Registers
(I/D Registers) feed the ALU inputs.
They allow the device to filter up to
sixteen data sets interleaved into the
same data stream without having to
separate the data sets. The I/D Registers should be set to a length equal
to the number of data sets interleaved
ODD-TAP INTERLEAVE MODE
together.
For example, if two data sets are
interleaved together, the I/D Registers
should be set to a length of two. Bits
1 through 4 of Configuration Register
1 and Configuration Register 3 determine the length of the I/D Registers in
Filters A and B respectively.
The I/D Registers also facilitate using
decimation to increase the number of
filter taps. Decimation by N is accomplished by reading the filter’s output
once every N clock cycles. The device
supports decimation up to 16:1. With
no decimation, the maximum number
of filter taps is sixteen. When decimating by N, the number of filter taps
becomes 16N because there are N–1
clock cycles when the filter’s output is
Video Imaging Products
2-10
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
TABLE 2. CONFIGURATION REGISTER 0 – ADDRESS 200H
BITS
0
FUNCTION
ALU Mode Filter A
DESCRIPTION
0: A + B
1
Pass A Filter A
1: B – A
0 : ALU Input A = 0
2
Pass B Filter A
1 : ALU Input A = Forward Register Path
0 : ALU Input B = 0
1 : ALU Input B = Reverse Register Path
11-3
Reserved
Should be set to “0”
TABLE 3. CONFIGURATION REGISTER 1 – ADDRESS 201H
BITS
0
4-1
FUNCTION
Filter A Odd-Tap
DESCRIPTION
0 : Odd-Tap Interleave Mode Disabled
Interleave Mode
Filter A I/D Register Length
1 : Odd-Tap Interleave Mode Enabled
0000:
1 Register
0001:
2 Registers
0010:
3 Registers
0011:
4 Registers
0100:
5 Registers
0101:
6 Registers
0110:
7 Registers
0111:
8 Registers
1000:
9 Registers
1001: 1
0 Registers
1010: 1
1 Registers
1011: 1
2 Registers
1100: 1
3 Registers
1101: 1
4 Registers
1110: 1
5 Registers
5
Filter A Tap Number
1111: 1
6 Registers
0 : Even Number of Taps
6
Filter A Data Reversal
1 : Odd Number of Taps
0 : Data Reversal Enabled
1 : Data Reversal Disabled
11-7
Reserved
Should be set to “0”
not being read. The extra clock cycles
are used to calculate more filter taps.
to a length of one.
When decimating, the I/D Registers
should be set to a length equal to the
decimation factor. For example, when
performing a 4:1 decimation, the
I/D Registers should be set to a
length of four. When decimation is
disabled or when only one data set
(non-interleaved data) is fed into the
device, the I/D Registers should be set
I/D Register Data Path Control
The three multiplexers in the I/D
Register data path control how data
is routed through the forward and
reverse data paths.
The forward data path contains the
I/D Registers in which data flows
from left to right in the block diagram
in Figure 1. The reverse data path
contains the I/D Registers in which
data flows from right to left.
In Single or Dual Filter Modes, data is
fed from the forward data path to the
reverse data path as follows. When
the filter is configured for an even
number of taps, data from the last
I/D Register in the forward data path
is fed into the first I/D Register in
the reverse data path (see Figure 13).
When the filter is configured for an
odd number of taps, the data which
will appear at the output of the last
I/D Register in the forward data path
on the next clock cycle is fed into the
first I/D Register in the reverse data
path. Bit 5 in Configuration Register
1 and Configuration Register 3 configures Filters A and B respectively for an
even or odd number of taps.
When interleaved data is fed through
the device and an even tap filter is
desired, the filter should be configured for an even number of taps and
the I/D Register length should match
the number of data sets interleaved
together. When interleaved data is fed
through the device and an odd tap
filter is desired, the filter should be set
to Odd-Tap Interleave Mode. Bit 0 of
Configuration Register 1 and Configuration Register 3 configures Filters A
and B respectively for Odd-Tap Interleave Mode. When the filter is configured for Odd-Tap Interleave Mode,
data from the next to last I/D Register
in the forward data path is fed into the
first I/D Register in the reverse data
path.
When the filter is configured for an
odd number of taps (interleaved or
non-interleaved modes), the filter is
structured such that the center data
value is aligned simultaneously at the
A and B inputs of the last ALU in the
forward data path. In order to achieve
the correct result, the user must divide
the coefficient by two.
Data Reversal
Data reversal circuitry is placed after
the multiplexers which route data
from the forward data path to the
Video Imaging Products
2-11
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
reverse data path (see Figure 14).
When decimating, the data stream
must be reversed in order for data to
be properly aligned at the inputs of
the ALUs.
When data reversal is enabled, the circuitry uses a pair of LIFOs to reverse
the order of the data sent to the
reverse data path. TXFRA and TXFRB
control the LIFOs in Filters A and B
FIGURE 14. DATA REVERSAL
TXFRA/TXFRB
LIFO A
LIFO B
respectively. When TXFRA/TXFRB
goes LOW, the LIFO sending data
to the reverse data path becomes the
LIFO receiving data from the forward
data path, and the LIFO receiving data
from the forward data path becomes
the LIFO sending data to the reverse
data path. The device must see a
HIGH to LOW transition of TXFRA/
TXFR B in order to switch LIFOs.
If decimating by N, TXFRA/TXFRB
should go LOW once every N clock
cycles. When data reversal is disabled, the circuitry functions like an
I/D Register. When feeding interleaved data through the filter, data
reversal should be disabled. Bit 6
of Configuration Register 1 and Configuration Register 3 enables or disables data reversal for Filters A
and B respectively.
Cascading
connected to DIN11-0 of another
device. ROUT11-0 of one device
should be connected to RIN11-0 of
another device. As many LF3320s
as desired may be cascaded together.
However, the outputs of the LF3320s
must be added together with external
adders.
Bit 0 of Configuration Register 5 determines how the device will send data
to the reverse data path when multiple LF3320s are cascaded together.
If a LF3320 is the last in the cascade
chain, Bit 0 of Configuration Register 5
should be set to a “0”. This will cause
the data from the end of the forward
data path to be routed to the beginning of the reverse data path based on
how the filter is configured (even/odd
number of taps or interleave mode). If
a LF3320 is not the last in the cascade
chain, Bit 0 of Configuration Register 5
should be set to a “1”. This will cause
1-16
Three cascade ports are provided to
allow cascading of multiple devices
for more filter taps (see Figure 15).
COUT11-0 of one device should be
FIGURE 15. MULTIPLE LF3320S CASCADED TOGETHER
LF3320
DIN
12
I/D
REGISTERS
I/D
REGISTERS
FILTER
A
FILTER
B
LF3320
RIN
COUT
ROUT
DIN
I/D
REGISTERS
I/D
REGISTERS
FILTER
A
FILTER
B
LF3320
RIN
ROUT
COUT
DIN
I/D
REGISTERS
I/D
REGISTERS
FILTER
A
FILTER
B
LF3320
RIN
COUT
ROUT
DIN
I/D
REGISTERS
I/D
REGISTERS
FILTER
A
FILTER
B
RSL
CIRCUIT
RSL
CIRCUIT
RSL
CIRCUIT
RSL
CIRCUIT
16
16
16
16
LF3347
25
25
RSL
CIRCUIT
16
DATA OUT
128 TAP RESULT
Video Imaging Products
2-12
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
RIN11-0 to feed data to the reverse data
path. When not cascading, Bit 0 of
Configuration Register 5 should be set
to a “0”.
Special data routing circuitry is used
to feed the COUT and ROUT output
registers. The data routing circuitry
is required to correctly align data in
the forward and reverse data paths
as data passes from one LF3320 to
another.
The COUT and ROUT registers are
loaded with data which is two clock
cycles behind the current output of
the I/D Register just before the ROUT
or COUT register. This correctly
accounts for the extra delays added to
the forward and reverse data paths by
the input/output cascade registers.
Output Adder
The Output Adder adds the Filter
A and B outputs together when the
device is in Single Filter Mode. If
24-bit data and 12-bit coefficients or
12-bit data and 24-bit coefficients are
desired, the LF3320 can facilitate this
by scaling the Filter B output by 2-12
before adding it to the Filter A output.
Bit 3 in Configuration Register 5 determines if the Filter B output is scaled
before being added to the Filter A
output.
Rounding
FIGURE 16. FILTER A AND B ROUND/SELECT/LIMIT CIRCUITRY
RSLB3-0
DATA IN
32
32
RSLA3-0
4
RB0
RA0
4
DATA IN
RND
RND
32
RB15
RA15
32
32
SELECT
SELECT
16
16
SB0
SA0
32
5
SB15
SA15
5
LB0
LA0
Output Select
LIMIT
32
LA15
LIMIT
LB15
32
FILTER B RSL
16
DATA OUT
The overall filter output (Single Filter
Mode) or Filter A and B outputs
(Dual Filter Mode) may be rounded
by adding the contents of one of the
sixteen Filter A or B round registers to
the overall filter, Filter A, or Filter B
outputs (see Figure 10). The Filter A
round registers are used for the
overall filter (Single Filter Mode) or
Filter A (Dual Filter Mode). The
Filter B round registers are used for
Filter B (Dual Filter Mode). Each
round register is 32-bits wide and
user-programmable. This allows the
filter’s output to be rounded to any
precision required. Since any 32-bit
value may be programmed into the
round registers, the device can support complex rounding algorithms as
well as standard Half-LSB rounding.
RSLA3-0 determines which of the sixteen Filter A round registers are used
in the Filter A rounding circuitry.
RSLB3-0 determines which of the sixteen Filter B round registers are used
in the Filter B rounding circuitry. A
value of 0 on RSLA/RSLB3-0 selects
Filter A/B round register 0. A value
of 1 selects Filter A/B round register
1 and so on. RSLA/RSLB3-0 may be
changed every clock cycle if desired.
This allows the rounding algorithm to
be changed every clock cycle. This is
useful when filtering interleaved data.
If rounding is not desired, a round
register should be loaded with 0 and
selected as the register used for rounding. Round register loading is discussed in the LF InterfaceTM section.
FILTER A RSL
16
DATA OUT
The word width of the overall filter,
Filter A, and Filter B outputs is
32-bits. However, only 16-bits may
be sent to DOUT15-0 (Single or
Dual Filter Modes) and COUT11-0/
ROUT3-0 (Dual Filter Mode). The
Filter A/B select circuitry determines
which 16-bits are passed (see Table 1).
The Filter A/B select registers control
the Filter A/B select circuitry. There
are sixteen Filter A and B select registers.
Video Imaging Products
2-13
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
TABLE 4. CONFIGURATION REGISTER 2 – ADDRESS 202H
BITS
0
FUNCTION
ALU Mode Filter B
DESCRIPTION
0: A + B
1
Pass A Filter B
1: B – A
0 : ALU Input A = 0
2
Pass B Filter B
1 : ALU Input A = Forward Register Path
0 : ALU Input B = 0
1 : ALU Input B = Reverse Register Path
11-3
Reserved
Must be set to “0”
TABLE 5. CONFIGURATION REGISTER 3 – ADDRESS 203H
BITS
0
4-1
FUNCTION
Filter B Odd-Tap
DESCRIPTION
0 : Odd-Tap Interleave Mode Disabled
Interleave Mode
Filter B I/D Register Length
1 : Odd-Tap Interleave Mode Enabled
0000:
1 Register
0001:
2 Registers
0010:
3 Registers
0011:
4 Registers
0100:
5 Registers
0101:
6 Registers
0110:
7 Registers
0111:
8 Registers
1000:
9 Registers
1001: 1
0 Registers
1010: 1
1 Registers
1011: 1
2 Registers
1100: 1
3 Registers
1101: 1
4 Registers
1110: 1
5 Registers
5
Filter B Tap Number
1111: 1
6 Registers
0 : Even Number of Taps
6
Filter B Data Reversal
1 : Odd Number of Taps
0 : Data Reversal Enabled
1 : Data Reversal Disabled
11-7
Reserved
The Filter A select registers are used
for the overall filter (Single Filter
Mode) or Filter A (Dual Filter Mode).
The Filter B select registers are used
for Filter B (Dual Filter Mode). Each
select register is 5 bits wide and userprogrammable. RSLA3-0 determines
which of the sixteen Filter A select registers are used in the Filter A select
circuitry. RSLB3-0 determines which
of the sixteen Filter B select registers
are used in the Filter B select circuitry.
A value of 0 on RSLA/RSLB3-0 selects
Filter A/B select register 0. A value
Must be set to “0”
of 1 selects Filter A/B select register
1 and so on. RSLA/RSLB3-0 may be
changed every clock cycle if desired.
This allows the 16-bit window to be
changed every clock cycle. This is
useful when filtering interleaved data.
Select register loading is discussed in
the LF InterfaceTM section.
Output Limiting
An output limiting function is provided for the overall filter, Filter A,
and Filter B outputs. The Filter A lim-
iting circuitry is used to limit the overall filter output (Single Filter Mode)
and the Filter A output (Dual Filter
Mode). The Filter B limiting circuitry
is used to limit the Filter B output
(Dual Filter Mode). The Filter A and B
limit registers determine the valid
range of output values for the Filter A
and B limiting circuitry respectively.
There are sixteen 32-bit
user-programmable limit registers for
both Filters A and B. The Filter A
limit registers are used for the overall
filter (Single Filter Mode) or Filter A
(Dual Filter Mode). The Filter B limit
registers are used for Filter B (Dual
Filter Mode). RSLA3-0 determines
which of the sixteen Filter A limit registers are used in the Filter A limit
circuitry. RSLB3-0 determines which
of the sixteen Filter B limit registers
are used in the Filter B limit circuitry.
A value of 0 on RSLA/RSLB3-0 selects
Filter A/B limit register 0. A value of
1 selects Filter A/B limit register 1 and
so on. Each limit register contains an
upper and lower limit value. If the
value fed to the limiting circuitry is
less than the lower limit, the lower
limit value is passed as the filter
output. If the value fed to the limiting
circuitry is greater than the upper
limit, the upper limit value is passed
as the filter output. Bit 1 and 0
in Configuration Register 4 enable
and disable Filter A and B limiting
respectively. RSLA/RSLB3-0 may be
changed every clock cycle if desired.
This allows the limit range to be
changed every clock cycle. This
is useful when filtering interleaved
data. When loading limit values into
the device, the upper limit must be
greater than the lower limit. Limit
register loading is discussed in the LF
InterfaceTM section.
Coefficient Banks
The coefficient banks store the coefficients which feed into the multipliers
in Filters A and B. There is a separate
bank for each multiplier. Each bank
can hold 256 12-bit coefficients. The
Video Imaging Products
2-14
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
banks are loaded using an LF InterfaceTM. There is a separate LF InterfaceTM for the Filter A and B banks.
Coefficient bank loading is discussed
in the LF InterfaceTM section.
Configuration and Control Registers
The configuration registers determine
how the LF3320 operates. Tables 2
through 7 show the formats of the
six configuration registers. There are
three types of control registers: round,
select, and limit. There are sixteen
round registers for Filter A and sixteen for Filter B. Each register is 32
bits wide. RSLA3-0 and RSLB3-0 determine which Filter A and B round registers respectively are used for rounding.
There are sixteen select registers for
Filter A and sixteen for Filter B.
Each register is 5 bits wide. RSLA3-0
and RSLB3-0 determine which Filter
A and B select registers respectively
are used in the select circuitry.
There are sixteen limit registers for
Filter A and sixteen for Filter B. Each
register is 32-bits wide and stores both
an upper and lower limit value. The
lower limit is stored in bits 15-0 and
the upper limit is stored in bits 31-16.
RSLA3-0 and RSLB3-0 determine which
Filter A and B limit registers respectively are used for limiting when limiting is enabled. Configuration and
control register loading is discussed in
the LF InterfaceTM section.
LF InterfaceTM
The Filter A and B LF InterfacesTM are
used to load data into the Filter A
and B coefficient banks respectively.
They are also used to load data into
the configuration and control registers.
The following section describes how
the Filter A LF InterfaceTM works. The
Filter A and B LF InterfacesTM are
identical in function. If LDA and
Horizontal Digital Image Filter
TABLE 6. CONFIGURATION REGISTER 4 – ADDRESS 204H
BITS
0
FUNCTION
Filter B Limit Enable
DESCRIPTION
0 : Limiting Disabled
1
Filter A Limit Enable
1 : Limiting Enabled
0 : Limiting Disabled
1 : Limiting Enabled
11-2
Reserved
Must be set to “0”
TABLE 7. CONFIGURATION REGISTER 5 – ADDRESS 205H
BITS
0
FUNCTION
Cascade Mode
DESCRIPTION
0 : Last In Line
1
Single/Dual Filter Mode
1 : First or Middle in Line
0 : Single Filter Mode
2
Filter B Input
1 : Dual Filter Mode
0 : RIN11-0
3
Output Adder Control
1 : DIN11-0
0 : Filter A + Filter B
4
Matrix Multiply Mode
1 : Filter A + Filter B (Filter B Scaled by 2-12)
0 : Disabled
5
Accumulator Access Mode
1 : Enabled
0 : Disabled
1 : Enabled
11-6
Reserved
Must be set to “0”
CFA11-0 are replaced with LDB and
CFB11-0, the following section will
describe how the Filter B LF InterfaceTM works.
should be loaded into the interface on
the same clock cycle that latches the
HIGH to LOW transition of LDA (see
Figures 17 and 18).
LDA is used to enable and disable the
Filter A LF InterfaceTM. When LDA
goes LOW, the Filter A LF InterfaceTM
is enabled for data input. The first
value fed into the interface on CFA11-0
is an address which determines what
the interface is going to load. The
three most significant bits (CFA11-9)
determine if the LF InterfaceTM will
load coefficient banks or
Configuration/control registers (see
Table 8). The nine least significant bits
(CFA8-0) are the address for whatever
is to be loaded (see Tables 9 through
14). For example, to load address 15
of the Filter A coefficient banks, the
first data value into the LF InterfaceTM
should be 00FH. To load Filter A limit
register 10, the first data value should
be C0AH. The first address value
The next value(s) loaded into the
interface are the data value(s) which
will be stored in the bank or register
defined by the address value. When
loading coefficient banks, the interface
will expect eight values to be loaded
into the device after the address value.
The eight values are coefficients 0
through 7. When loading configuration or select registers, the interface
will expect one value after the address
value. When loading round or limit
registers, the interface will expect four
values after the address value. Figures 11 and 12 show the data loading
sequences for the coefficient banks
and Configuration/control registers.
Both PAUSEA and PAUSEB allow the
user to effectively slow the rate of data
Video Imaging Products
2-15
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
loading through the LF InterfaceTM.
When PAUSEA is HIGH, the LF InterfaceTM affecting the data used for Filter
A is held until PAUSEA is returned to
a LOW. When PAUSEB is HIGH,
the LF InterfaceTM affecting the data
used for Filter B is held until PAUSEB
is returned to a LOW. Figures 19
through 22 display the effects of both
PAUSEA and PAUSEB while loading
Horizontal Digital Image Filter
coefficient and control data.
Table 15 shows an example of loading
data into the coefficient banks. The
following data values are written into
address 10 of coefficient banks 0
through 7: 210H, 543H, C76H, 9E3H,
701H, 832H, F20H, 143H. Table 16
shows an example of loading data
into a Configuration Register. Data
value 003H is written into Configura-
tion Register 4. Table 17 shows an
example of loading data into a round
register. Data value 7683F4A2H is
written into Filter A round register 12.
Table 18 shows an example of loading
data into a select register. Data value
00FH is loaded into Filter A select register 2. Table 19 shows an example of
loading data into Filter B limit register
7. Data value 3B60H is loaded as the
FIGURE 17. COEFFICIENT BANK LOADING SEQUENCE
COEFFICIENT SET 1
COEFFICIENT SET 2
COEFFICIENT SET 3
CLK
W1
W2
W3
LDA/LDB
ADDR1
CFA/CFB11-0
COEF0
COEF7
ADDR2
COEF0
COEF7
ADDR3
COEF0
COEF7
W1: Coefficient Set 1 written to coefficient banks during this clock cycle.
W2: Coefficient Set 2 written to coefficient banks during this clock cycle.
W3: Coefficient Set 3 written to coefficient banks during this clock cycle.
FIGURE 18. CONFIGURATION/CONTROL REGISTER LOADING SEQUENCE
CONFIG REG
ROUND REGISTER
SELECT REG
LIMIT REGISTER
CLK
W1
W2
W3
W4
LDA/LDB
ADDR1
CFA/CFB11-0
DATA1
ADDR2
DATA1
ADDR3
DATA1
DATA2
DATA3
DATA4
ADDR4
DATA1
DATA2
DATA3
DATA4
W1: Configuration Register loaded with new data on this rising clock edge.
W2: Select Register loaded with new data on this rising clock edge.
W3: Round Register loaded with new data on this rising clock edge.
W4: Limit Register loaded with new data on this rising clock edge.
FIGURE 19. COEFFICIENT BANK LOADING SEQUENCE WITH PAUSE IMPLEMENTATION
COEFFICIENT SET 1
CLK
W1
PAUSEA/PAUSEB
LDA/LDB
CFA/CFB11-0
ADDR1
COEF0
COEF1
COEF7
W1: Coefficient Set 1 written to coefficient banks during this clock cycle.
Video Imaging Products
2-16
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
lower limit and 72A4H is loaded as
the upper limit.
It takes 9S clock cycles to load S coefficient sets into the device. Therefore,
it takes 2304 clock cycles to load all
256 coefficient sets. Assuming an 83
MHz clock rate, all 256 coefficient sets
can be updated in less than 27.7 µs,
which is well within vertical blanking
time. It takes 5S clock cycles to load
S round or limit registers. Therefore,
it takes 320 clock cycles to update all
round and limit registers (both Filters
A and B). Assuming an 83 MHz clock
rate, all Filter A and B round/limit
registers can be updated in 3.84 µs.
The coefficient banks and
Configuration/Control registers are
not loaded with data until all data
values for the specified address are
loaded into the LF InterfaceTM. In
other words, the coefficient banks are
not written to until all eight coefficients have been loaded into the LF
InterfaceTM. A round register is not
written to until all four data values are
loaded.
After the last data value is loaded, the
interface will expect a new address
value on the next clock cycle. After
the next address value is loaded, data
loading will begin again as previously
discussed. As long as data is loaded
into the interface, LDA must remain
LOW. After all desired coefficient
banks and Configuration/Control registers are loaded with data, the LF
InterfaceTM must be disabled. This is
done by setting LDA HIGH on the
clock cycle after the clock cycle which
latches the last data value. It is impor-
tant that the LF InterfaceTM remain disabled when not loading data into it.
The Filter A coefficient banks may
only be loaded with the Filter A
LF InterfaceTM and the Filter B coefficient banks may only be loaded with
the Filter B LF InterfaceTM. The Configuration and Control registers may
be loaded with either the Filter A or B
TABLE 8. CFA/CFB11-9 DECODE
11
0
0
0
0
1
1
1
10
0
0
1
1
0
0
1
9
0
1
0
1
0
1
0
DESCRIPTION
Coefficient Banks
Configuration Registers
Filter A Select Registers
Filter B Select Registers
Filter A Round Registers
Filter B Round Registers
Filter A Limit Registers
1 1 1 Filter B Limit Registers
FIGURE 20. CONFIGURATION AND SELECT REGISTER LOADING SEQUENCE WITH PAUSE IMPLEMENTATION
SELECT REGISTER
CONFIGURATION REGISTER
CLK
W1
W2
PAUSEA/PAUSEB
LDA/LDB
CFA/CFB11-0
ADDR1
DATA1
ADDR2
DATA1
W1: Configuration Register loaded with new data on this rising clock edge.
W2: Select Register loaded with new data on this rising clock edge.
FIGURE 21. ROUND REGISTER LOADING SEQUENCE WITH PAUSE IMPLEMENTATION
ROUND REGISTER
CLK
W1
PAUSEA/PAUSEB
LDA/LDB
CFA/CFB11-0
ADDR1
DATA1
DATA2
DATA3
DATA4
W1: Round Register loaded with new data on this rising clock edge.
Video Imaging Products
2-17
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
FIGURE 22. LIMIT REGISTER LOADING SEQUENCE WITH PAUSE IMPLEMENTATION
LIMIT REGISTER
CLK
W1
PAUSEA/PAUSEB
LDA/LDB
CFA/CFB11-0
ADDR1
DATA1
DATA2
DATA3
DATA4
W1: Limit Register loaded with new data on this rising clock edge.
TABLE 9. FLTR. A ROUND REGIS-
TABLE 10. FLTR.A SELECT REGIS-
TABLE 11. FLTR. A LIMIT REGIS-
REGISTER
0
1
ADDRESS (HEX)
800
801
REGISTER
0
1
ADDRESS (HEX)
400
401
REGISTER
0
1
ADDRESS (HEX)
C00
C01
14
80E
14
40E
14
C0E
15
80F
15
40F
15
C0F
TABLE 12. FLTR. B ROUND REGIS-
TABLE 13. FLTR.B SELECT REGIS-
TABLE 14. FLTR. B LIMIT REGIS-
REGISTER
0
1
ADDRESS (HEX)
A00
A01
REGISTER
0
1
ADDRESS (HEX)
600
601
REGISTER
0
1
ADDRESS (HEX)
E00
E01
14
A0E
14
60E
14
E0E
15
A0F
15
60F
15
E0F
LF InterfacesTM.
Since both LF InterfacesTM operate
independently of each other, both LF
InterfacesTM can load data into their
respective coefficient banks at the
same time. Or, one LF InterfaceTM can
load the Configuration/Control registers while the other loads it’s respective coefficient banks. If both LF InterfacesTM are used to load a Configuration or Control register at the same
time, the Filter B LF InterfaceTM will
be given priority over the Filter A LF
InterfaceTM. For example, if the Filter
A LF InterfaceTM attempts to load data
into a configuration register at the
same time that the Filter B LF InterfaceTM attempts to load a Filter A
round register, the Filter B LF InterfaceTM will be allowed to load the
round register while the Filter A LF
InterfaceTM will not be allowed to
load the configuration register. However, the Filter A LF InterfaceTM will
continue to function as if the write
occurred.
Video Imaging Products
2-18
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
TABLE 15. COEFFICIENT BANK LOADING FORMAT
1st Word - Address
2nd Word - Bank 0
3rd Word - Bank 1
4th Word - Bank 2
5th Word - Bank 3
6th Word - Bank 4
7th Word - Bank 5
8th Word - Bank 6
9th Word - Bank 7
CFA/B11 CFA/B10 CFA/B9 CFA/B8 CFA/B7 CFA/B6 CFA/B5 CFA/B4 CFA/B3 CFA/B2 CFA/B1 CFA/B0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
1
0
0
0
0
1
0
0
0
0
0
1
0
1
0
1
0
0
0
0
1
1
1
1
0
0
0
1
1
1
0
1
1
0
1
0
0
1
1
1
1
0
0
0
1
1
0
1
1
1
0
0
0
0
0
0
0
1
1
0
0
0
0
0
1
1
0
0
1
0
1
1
1
1
0
0
1
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
1
1
TABLE 16. CONFIGURATION REGISTER LOADING FORMAT
1st Word - Address
2nd Word - Data
CFA/B11 CFA/B10 CFA/B9 CFA/B8 CFA/B7 CFA/B6 CFA/B5 CFA/B4 CFA/B3 CFA/B2 CFA/B1 CFA/B0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
TABLE 17. ROUND REGISTER LOADING FORMAT
CFA/B11 CFA/B10 CFA/B9 CFA/B8 CFA/B7 CFA/B6 CFA/B5 CFA/B4 CFA/B3 CFA/B2 CFA/B1 CFA/B0
1st Word - Address
1
0
0
0
0
0
0
0
1
1
0
0
2nd Word - Data
R
R
R
R
1
0
1
0
0
0
1
0*
3rd Word - Data
R
R
R
R
1
1
1
1
0
1
0
0
4th Word - Data
R
R
R
R
1
0
0
0
0
0
1
1
5th Word - Data
R
R
R
R
0**
1
1
1
0
1
1
0
TABLE 18. SELECT REGISTER LOADING FORMAT
CFA/B11 CFA/B10 CFA/B9 CFA/B8 CFA/B7 CFA/B6 CFA/B5 CFA/B4 CFA/B3 CFA/B2 CFA/B1 CFA/B0
1st Word - Address
0
1
0
0
0
0
0
0
0
0
1
0
2nd Word - Data
0
0
0
0
0
0
0
0
1
1
1
1
TABLE 19. LIMIT REGISTER LOADING FORMAT
CFA/B11 CFA/B10 CFA/B9 CFA/B8 CFA/B7 CFA/B6 CFA/B5 CFA/B4 CFA/B3 CFA/B2 CFA/B1 CFA/B0
1st Word - Address
1
1
1
0
0
0
0
0
0
1
1
1
2nd Word - Data
R
R
R
R
0
1
1
0
0
0
0
0
3rd Word - Data
R
R
R
R
0*
0
1
1
1
0
1
1
4th Word - Data
R
R
R
R
1
0
1
0
0
1
0
0
5th Word - Data
R
R
R
R
0**
1
1
1
0
0
1
0
R = Reserved. Must be set to “0”.
* This bit represents the MSB of the Lower Limit.
** This bit represents the MSB of the Upper Limit.
Video Imaging Products
2-19
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
MAXIMUM RATINGS Above which useful life may be impaired (Notes 1, 2, 3, 8)
Storage temperature ............................................................................................................ –65°C to +150°C
Operating ambient temperature ........................................................................................... –55°C to +125°C
VCC supply voltage with respect to ground ............................................................................ –0.5 V to +4.5 V
Input signal with respect to ground .......................................................................................... –0.5 V to 5.5 V
Signal applied to high impedance output ................................................................................. –0.5 V to 5.5 V
Output current into low outputs ............................................................................................................ 25 mA
Latchup current ............................................................................................................................... > 400 mA
ESD Classification (MIL-STD-883E METHOD 3015.7) ....................................................................... Class 3
OPERATING CONDITIONS To meet specified electrical and switching characteristics
Mode
Temperature Range (Ambient)
Active Operation, Commercial
Active Operation, Military
Supply Voltage
0°C to +70°C
3.00 V ≤ VCC ≤ 3.60 V
–55°C to +125°C
3.00 V ≤ VCC ≤ 3.60 V
ELECTRICAL CHARACTERISTICS Over Operating Conditions (Note 4)
Symbol
Parameter
Test Condition
Min
VOH
Output High Voltage
VCC = Min., IOH = –4 mA
2.4
VOL
Output Low Voltage
VCC = Min., IOL = 8.0 mA
VIH
Input High Voltage
VIL
Input Low Voltage
(Note 3)
IIX
Input Current
IOZ
Typ
Max
Unit
V
0.4
V
2.0
5.5
V
0.0
0.8
V
Ground ≤ VIN ≤ VCC (Note 12)
±10
µA
Output Leakage Current
Ground ≤ VOUT ≤ VCC (Note 12)
±10
µA
ICC1
VCC Current, Dynamic
(Notes 5, 6)
200
mA
ICC2
VCC Current, Quiescent
(Note 7)
2
mA
CIN
Input Capacitance
TA = 25°C, f = 1 MHz
10
pF
COUT
Output Capacitance
TA = 25°C, f = 1 MHz
10
pF
Video Imaging Products
2-20
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
SWITCHING CHARACTERISTICS
COMMERCIAL OPERATING RANGE (0°C to +70°C) Notes 9, 10 (ns)
LF3320–
25
Symbol
15
Min
Max
Min
9
Min
tCYC
Cycle Time
25
15
12
9
tPWL
Clock Pulse Width Low
10
7
5
5
tPWH
Clock Pulse Width High
10
7
5
5
tS
Input Setup Time
8
5
4
4
tH
Input Hold Time
0
0
0
0
tSCT
Setup Time Control Inputs
8
5
4
4
tHCT
Hold Time Control Inputs
0
0
0
0
tSCC
Setup Time Coefficient Control Inputs
8
5
4
4
tHCC
Hold Time Coefficient Control Inputs
0
0
0
0
tD
Output Delay
13
9
7
7
tDCC
Cascade Output Delay
13
9
7.5
7.5
tDIS
Three-State Output Disable Delay (Note 11)
15
12
10
10
tENA
Three-State Output Enable Delay (Note 11)
15
12
10
10
SWITCHING WAVEFORMS:
Max
12
Parameter
Max
Min
Max
DATA I/O
1
2
3
4
5
6
7
CLK
DIN11-0
RIN11-0
ACA8-0
BCA8-0
CONTROLS
(Except OED & OEC)
tS
tH
DIN/RINN
tSCC
tHCC
CAA/CABN
tSCT
OED
OEC
tPWH
DIN/RINN+1
tCYC
CAA/CABN+1
tHCT
tDIS
tENA
HIGH IMPEDANCE
DOUT15-0
tDIS
ROUT11-0/COUT11-0
tPWL
tD
OUTPUTN-1
tENA
HIGH IMPEDANCE
OUTPUTN
tDCC
OUTPUTN-1
OUTPUTN
*DISCONTINUED SPEED GRADE
Video Imaging Products
2-21
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
COMMERCIAL OPERATING RANGE (0°C to +70°C) Notes 9, 10 (ns)
LF3320–
25
Symbol
Parameter
Min
15
Max
Min
12
Max
Min
9
Max
Min
Max
tCFS
Coefficient Input Setup Time
8
6
5.5
5.5
tCFH
Coefficient Input Hold Time
0
0
0
0
tLS
Load Setup Time
8
6
4
4
tLH
Load Hold Time
0
0
0
0
tPS
PAUSE Setup Time
8
5
4
4
tPH
PAUSE Hold Time
0
0
0
0
SWITCHING WAVEFORMS:
LF INTERFACETM
1
2
3
4
5
6
CLK
LDA
LDB
tLS
tLH
tPWL
tCYC
tPS
PAUSEA
PAUSEB
CFA11–0
CFB11–0
tPWH
tCFS
tPH
tCFH
ADDRESS
CF0
CF1
CF2
*DISCONTINUED SPEED GRADE
Video Imaging Products
2-22
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
NOTES
1. Maximum Ratings indicate stress
specifications only. Functional operation of these products at values
beyond those indicated in the Operating Conditions table is not implied.
Exposure to maximum rating conditions for extended periods may affect
reliability.
but not 100% tested.
9. AC specifications are tested with
input transition times less than 3 ns,
output reference levels of 1.5 V (except
tDIS test), and input levels of nominally
0 to 3.0 V. Output loading may be a
resistive divider which provides for
specified IOH and IOL at an output
voltage of VOH min and VOL max
respectively. Alternatively, a diode
bridge with upper and lower current
sources of IOH and IOL respectively,
and a balancing voltage of 1.5 V may
be used. Parasitic capacitance is 30 pF
minimum, and may be distributed.
case operation of any device always
provides data within that time.
11. For the tENA test, the transition is
measured to the 1.5 V crossing point
with datasheet loads.
For
the
tDIS test, the transition is measured
to the ±200mV level from the measured steady-state output voltage with
±10mA loads. The balancing voltage,
VTH, is set at 3.0 V for Z-to-0 and 0-to-Z
tests, and set at 0 V for Z-to-1 and
1-to-Z tests.
2. The products described by this specification include internal circuitry
designed to protect the chip from
damaging substrate injection currents
and accumulations of static charge.
12. These parameters are only tested at
Nevertheless, conventional precauthe high temperature extreme, which is
tions should be observed during storthe worst case for leakage current.
age, handling, and use of these circuits
This
device
has
high-speed
outputs
in order to avoid exposure to excessive
capable of large instantaneous current
electrical stress values.
pulses and fast turn-on/turn-off times.
FIGURE A. OUTPUT LOADING CIRCUIT
3. This device provides hard clamping As a result, care must be exercised in
of transient undershoot. Input levels the testing of this device. The following
below ground will be clamped begin- measures are recommended:
S1
DUT
ning at –0.6 V. The device can withIOL
stand indefinite operation with inputs a. A 0.1 µF ceramic capacitor should
VTH
CL
or outputs in the range of –0.5 V to be installed between VCC and Ground
IOH
leads
as
close
to
the
Device
Under
Test
+5.5 V. Device operation will not be
adversely affected, however, input (DUT) as possible. Similar capacitors
current levels will be well in excess should be installed between device
VCC and the tester common, and device
FIGURE B. THRESHOLD LEVELS
of 100 mA.
ground and tester common.
tENA
tDIS
4. Actual test conditions may vary
OE
1.5 V
1.5 V
from those designated but operation is b. Ground and VCC supply planes
must be brought directly to the DUT
3.0V Vth
Z
0
guaranteed as specified.
1.5 V
VOL*
0.2 V
socket or contactor fingers.
0
Z
5. Supply current for a given applica1
Z
0.2 V
VOH*
1.5 V
tion can be accurately approximated c. Input voltages on a test fixture
0V Vth
Z
1
should be adjusted to compensate for
by:
VOL* Measured VOL with IOH = –10mA and IOL = 10mA
inductive ground and VCC noise to
NCV2 F
VOH* Measured VOH with IOH = –10mA and IOL = 10mA
maintain required DUT input levels
4
relative to the DUT ground pin.
where
10. Each parameter is shown as a
N = total number of device outputs
minimum or maximum value. Input
C = capacitive load per output
requirements are specified from the
V = supply voltage
point of view of the external system
F = clock frequency
driving the chip. Setup time, for
example, is specified as a minimum
6. Tested with outputs changing every since the external system must supply
cycle and no load, at a 40 MHz clock at least that much time to meet the
rate.
worst-case requirements of all parts.
7. Tested with all inputs within 0.1 V of Responses from the internal circuitry
are specified from the point of view of
VCC or Ground, no load.
the device. Output delay, for example,
8. These parameters are guaranteed is specified as a maximum since worst-
Video Imaging Products
2-23
6/22/2007–LDS.3320-R
LF3320
DEVICES INCORPORATED
Horizontal Digital Image Filter
144-pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
Top
View
108
107
106
105
104
103
102
101
100
99
98
97
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
GND
COUT11
COUT10
COUT9
COUT8
COUT7
COUT6
COUT5
COUT4
COUT3
COUT2
COUT1
COUT0
GND
VCC
CENB
CAB7
CAB6
CAB5
CAB4
CAB3
CAB2
CAB1
CAB0
CFB11
CFB10
CFB9
CFB8
CFB7
CFB6
CFB5
CFB4
CFB3
CFB2
CFB1
CFB0
LDA
PAUSEA
ACCA
RSLA3
RSLA2
RSLA1
RSLA0
VCC
GND
DOUT15
DOUT14
DOUT13
DOUT12
DOUT11
DOUT10
DOUT9
DOUT8
GND
OED
DOUT7
DOUT6
DOUT5
DOUT4
DOUT3
DOUT2
DOUT1
DOUT0
GND
VCC
RSLB0
RSLB1
RSLB2
RSLB3
ACCB
PAUSEB
LDB
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
VCC
DIN11
DIN10
DIN9
DIN8
DIN7
DIN6
DIN5
DIN4
DIN3
DIN2
DIN1
DIN0
GND
VCC
CENA
CAA7
CAA6
CAA5
CAA4
CAA3
CAA2
CAA1
CAA0
CFA11
CFA10
CFA9
CFA8
CFA7
CFA6
CFA5
CFA4
CFA3
CFA2
CFA1
CFA0
144
143
142
141
140
139
138
137
136
135
134
133
132
131
130
129
128
127
126
125
124
123
122
121
120
119
118
117
116
115
114
113
112
111
110
109
GND
ROUT11
ROUT10
ROUT9
ROUT8
ROUT7
ROUT6
ROUT5
ROUT4
ROUT3
ROUT2
ROUT1
ROUT0
GND
VCC
SHENA
TXFRA
GND
CLK
VCC
TXFRB
SHENB
RIN0
RIN1
RIN2
RIN3
RIN4
RIN5
RIN6
RIN7
RIN8
RIN9
RIN10
RIN11
OEC
VCC
ORDERING INFORMATION
Plastic Quad Flatpack
(Q5)
Speed
0°C to +70°C — COMMERCIAL SCREENING
15 ns
15 ns
12 ns
12 ns
9 ns
LF3320QC15
LF3320QC15 (GREEN)
LF3320QC12
LF3320QC12G (GREEN)
LF3320QC9
LOGIC Devices Incorporated reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and
to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current
and complete. LOGIC Devices does not assume any liability arising out of the application or use of any product or circuit described herein. In no event shall any liability exceed
the purchase price of LOGIC Devices products. LOGIC Devices products are not warranted nor intended to be used for medical, life support, life saving, critical control or safety
applications, unless pursuant to an express written agreement with LOGIC Devices. Furthermore, LOGIC Devices does not authorize its products for use as critical components in
life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user.
Video Imaging Products
2-24
6/22/2007–LDS.3320-R