www.hammondmfg.com 1485 Series Lay-In Wireway - NEMA 12 Wireway & Trough Application Construction Finish • Designed to enclose and protect electrical wiring from dirt, dust, oil and water. • All sections and fittings are completely open on each side to allow wires and cables to be placed into the wireway without “pulling through”. • Bodies and covers are formed from 14-gauge steel with 10 gauge steel flanges. • 12” x 6” size has a 12 gauge steel body with a 14-gauge cover. • Smooth continuously welded seams. • Interior surfaces are smooth to prevent wire damage during installation. • Butt hinged cover is secured with easily operated quick release clamps. • Oil resistant gaskets are permanently secured. • Solid oil resistant gaskets are used between flanges when sections and fittings are bolted together. • One gasket kit, complete with hardware is provided with each straight section or fitting. • Sealing plate is supplied. • Flange junctions are sealed with gasket sealing plates, which are put in place after wiring is completed. One is supplied with all straight sections and most fittings; see table for exact number. • Sections and components are finished in ANSI 61 gray powder coating. Standards Lay-In Wireway • UL 870 Type 1 (unless marked1) • CSA Type 1 (unless marked1) • Complies with • NEMA Type 12 • JIC EMP-1-1967 • JIC EGP-1-1967 • IEC 60529, IP54 Technical references and CAD downloads available at www.hammondmfg.com 273 Notes • When joining a wireway section or fitting to an enclosure be sure to order a box connector. • When joining two wireway sections, or joining a wireway section to a fitting, a flat sealing plate is required at each junction; necessary kits are supplied with each section and fitting. See table, extra kits may be ordered if necessary. • When joining a lay-in wireway section or fitting to a closure plate, a box connector, or cut-off fitting, an angle sealing plate is required at each junction. • Necessary kits are supplied with each section and fitting - see table. Extra kits, although not normally required, are necessary when joining lay-in wireway to a non-lay-in section or fitting section. All dimensions in inches unless specified otherwise Quality Products. Service Excellence. © Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 USA: 716.630.7030 Data Subject to change without notice www.hammondmfg.com 1485 Series Lay-In Wireway - NEMA 12 Description 4x4 Part No. 1485C6 1485C12 1485C24 1485C36 1485C48 1485C60 1485C120 1487CB601 1485CM1 1485CM2 1485CM3 1485CV1 1485CV2 1485CZ12 1485CZC12 1485CFF 1485CX1 1485CW11 1485CW21 1485C9N 1485C9P 1485C9Q 1485C4N 1485C4P 1485C4Q 1485CTN 1485CTQ 1485CY 1485CRE — — — — 1485CJ 1485CK1 1485CL11 1485CL21 1485CH2 1485CSM2 1485CS92 6x6 Part No. 1485D6 1485D12 1485D24 1485D36 1485D48 1485D60 1485D120 1487DB601 1485DM1 1485DM2 1485DM3 1485DV1 1485DV2 1485DZ12 1485DZC12 1485DFF 1485DX1 1485DW11 1485DW21 1485D9N 1485D9P 1485D9Q 1485D4N 1485D4P 1485D4Q 1485DTN 1485DTQ 1485DY — 1485DRE — — — 1485DJ 1485DK1 1485DL11 1485DL21 1485DH2 1485DSM2 1485DS92 8x8 Part No. 1485E6 1485E12 1485E24 1485E36 1485E48 1485E60 1485E120 1487EB601 — — — 1485EV1 1485EV2 1485EZ12 1485EZC12 1485EFF 1485EX1 1485EW11 1485EW21 1485E9N 1485E9P 1485E9Q 1485E4N 1485E4P 1485E4Q 1485ETN 1485ETQ 1485EY — — 1485ERE — — 1485EJ 1485EK1 1485EL11 1485EL21 1485EH2 1485ESM2 1485ES92 12 x 6 Part No. 1485F6 1485F12 1485F24 1485F36 1485F48 1485F60 1485F120 1487DB601 — — — — — — — — 1485FX1 1485FW11 1485FW21 1485F9N 1485F9P 1485F9Q 1485F4N — — 1485FTN — 1485FY — — — 1485FREC 1485FRED — 1485FK1 — — 1485FH2 1485FSM2 1485FS92 Does not meet CSA or UL requirements Maintains ratings on CSA and UL approved wireway Technical references and CAD downloads available at www.hammondmfg.com All dimensions in inches unless specified otherwise Quality Products. Service Excellence. © Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 Lay-In Wireway 1 2 2.5 x 2.5 Part No. 1485B6 1485B12 1485B24 1485B36 1485B48 1485B60 1485B120 — 1485BM1 1485BM2 1485BM3 1485BV1 1485BV2 1485BZ12 1485BZC12 1485BFF 1485BX1 1485BW11 1485BW21 1485B9N 1485B9P 1485B9Q 1485B4N 1485B4P 1485B4Q 1485BTN 1485BTQ 1485BY — — — — — 1485BJ 1485BK1 1485BL11 1485BL21 1485BH2 1485BSM2 1485BS92 Wireway & Trough 6" Section 12" Section 24" Section 36" Section 48" Section 60" Section 120" Section 60" Long Partition (Barrier) 1" Nipple 2" Nipple 3" Nipple Box Entry Swivel Nipple Standard Swivel Nipple 12" Transposition Clockwise 12" Transposition Counter-Clockwise Flexible Fitting Adjustable Fitting Cut-Off Fitting Lay-In Cut-Off Fitting Non Lay-In 90° Elbow, Top Opening 90° Elbow, Inside Opening 90° Elbow, Outside Opening 45° Elbow, Top Opening 45° Elbow, Inside Opening 45° Elbow, Outside Opening Tee Fitting, Top Opening Tee Fitting, Outside & Top Opening Cross Fitting Reducer 4 x 4 to 2.5 x 2.5 Reducer 6 x 6 to 4 x 4 Reducer 8 x 8 to 6 x 6 Reducer 12 x 6 to 4 x 4 Reducer 12 x 6 to 6 x 6 Junction Box Box Connector Drop Hanger Bracket Hanger Cover Plate Snap On Flat Sealing Plate Angle Sealing Plate Sealing Plates Supplied 1 Flat 1 Flat 1 Flat 1 Flat 1 Flat 1 Flat 1 Flat — 1 Flat 1 Flat 1 Flat 1 Angle 2 Angle 1 Flat 1 Flat None 1 Spec. 1 Flat 1 Angle 1 Flat 1 Flat 1 Flat 1 Flat 1 Flat 1 Flat 2 Flat 2 Flat 3 Flat None None None None None 1 Flat 1 Angle None None 1 Angle None None USA: 716.630.7030 Data Subject to change without notice 274 www.hammondmfg.com 1485 Series Lay-In Wireway - NEMA 12 Wireway & Trough Lay-In Wireway All unmarked diameters are 0.28 All unmarked radii are 0.38 Technical references and CAD downloads available at www.hammondmfg.com 275 All dimensions in inches unless specified otherwise Quality Products. Service Excellence. © Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 USA: 716.630.7030 Data Subject to change without notice www.hammondmfg.com 1485 Series Lay-In Wireway - NEMA 12 Angle Sealing Plate Partition (Barrier) Kit Part No. Size 1485BSM 2.5 x 2.5 1485CSM 4x4 1485DSM 6x6 1485ESM 8x8 1485FSM 12 x 6 Maintains ratings on CSA and UL approved wireway Part No. Size 1485BS9 2.5 x 2.5 1485CS9 4x4 1485DS9 6x6 1485ES9 8x8 1485FS9 12 x 6 Maintains ratings on CSA and UL approved wireway • Divides wireway into two or more compartments. Barriers are fastened to wireway sections with screws. Part No. 1487CB60 1487DB60 1487EB60 1487DB60 Size 4x4 6x6 8x8 12 x 6 X 3.72 5.72 7.72 5.72 Does not meet CSA or UL requirements Wireway & Trough Snap On Flat Sealing Plate Typical Straight Section C=36" Section Part No. 1485B36 1485C36 1485D36 1485E36 1485F36 C=48" Section Part No. 1485B48 1485C48 1485D48 1485E48 1485F48 C=60" Section Part No. 1485B60 1485C60 1485D60 1485E60 1485F60 C=120" Section Part No. 1485B120 1485C120 1485D120 1485E120 1485F120 Size 2.5 x 2.5 4x4 6x6 8x8 12 x 6 Box Entry or Standard Swivel Nipple Box Entry Swivel Nipple Part No. 1485BV11 1485CV11 1485DV11 1485EV11 1 One angle sealing plate included 2 Standard Swivel Nipple Part No. 1485BV22 1485CV22 1485DV22 1485EV22 Size 2.5 x 2.5 4x4 6x6 8x8 Two angle sealing plates included Technical references and CAD downloads available at www.hammondmfg.com All dimensions in inches unless specified otherwise Quality Products. Service Excellence. © Hammond Manufacturing Lay-In Wireway C=6" Sec- C=12" C=24" tion Section Section Part No. Part No. Part No. 1485B6 1485B12 1485B24 1485C6 1485C12 1485C24 1485D6 1485D12 1485D24 1485E6 1485E12 1485E24 1485F6 1485F12 1485F24 One flat sealing plate included Canada: 519.822.2960 or 905.456.3770 USA: 716.630.7030 Data Subject to change without notice 276 www.hammondmfg.com 1485 Series Lay-In Wireway - NEMA 12 Wireway & Trough Flexible Fitting Adjustable Fitting • Allows for easy alignment of sections or fittings • Metal flanges • Flexible synthetic "bellows" middle section • Allows on site length adjustment of 2" to 7" Part No. 1485BFF 1485CFF 1485DFF 1485EFF A 2.5 4 6 8 B 2.5 4 6 8 Part No. 1485BX 1485CX 1485DX 1485EX 1485FX Size 2.5 x 2.5 4x4 6x6 8x8 12 x 6 Part No. Size H 1485BY 2.5 x 2.5 8.50 1485CY 4x4 10.00 1485DY 6x6 12.00 1485EY 8x8 14.00 1485FY 12 x 6 18.00 Three flat sealing plates included One special sealing plate included Does not meet CSA or UL requirements M 4.25 5.00 6.00 7.00 9.00 Lay-In Wireway Cut-Off Fitting (Lay-In) Cut-Off Fitting (Non Lay-in) Typical Nipple • Body comes in two pieces. Cut-off one piece, shorten cover, and weld together. • Includes angle sealing plate. • For lengths up to 12”. Cut off body and weld on flange. • Lay-in nipples come with a special sealing plate which cannot be used adjacent to swivel nipples (use 1487 Series nipples) Part No. 1485BW1 1485CW1 1485DW1 1485EW1 1485FW1 Part No. 1485BW2 1485CW2 1485DW2 1485EW2 1485FW2 1" Nipple 2" Nipple 3" Nipple Size Part No. Part No. Part No. 1485BM1 1485BM2 1485BM3 2.5 x 2.5 1485CM1 1485CM2 1485CM3 4x4 1485DM1 1485DM2 1485DM3 6x6 One flat sealing plate included Size 2.5 x 2.5 4x4 6x6 8x8 12 x 6 One flat sealing plate included Does not meet CSA or UL requirements Size 2.5 x 2.5 4x4 6x6 8x8 12 x 6 One angle sealing plate included Does not meet CSA or UL requirements Technical references and CAD downloads available at www.hammondmfg.com 277 Cross Fitting All dimensions in inches unless specified otherwise Quality Products. Service Excellence. © Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 USA: 716.630.7030 Data Subject to change without notice www.hammondmfg.com 1485 Series Lay-In Wireway - NEMA 12 Part No. Size 1485B4N 2.5 x 2.5 1485C4N 4x4 1485D4N 6x6 1485E4N 8x8 1485F4N 12 x 6 One flat sealing plate included 45° Elbow Inside Opening K 2.28 2.60 3.00 3.41 4.24 Part No. Size 1485B9N 2.5 x 2.5 1485C9N 4x4 1485D9N 6x6 1485E9N 8x8 1485F9N 12 x 6 One flat sealing plate included Y 2.28 2.59 3.00 3.41 Part No. Size 1485B4Q 2.5 x 2.5 1485C4Q 4x4 1485D4Q 6x6 1485E4Q 8x8 One flat sealing plate included 90° Elbow Inside Opening M 4.25 5.00 6.00 7.00 9.00 Part No. Size 1485B9P 2.5 x 2.5 1485C9P 4x4 1485D9P 6x6 1485E9P 8x8 1485F9P 12 x 6 One flat sealing plate included Technical references and CAD downloads available at www.hammondmfg.com Z 2.29 2.61 3.02 3.44 Lay-In Wireway 90° Elbow Top Opening Part No. Size 1485B4P 2.5 x 2.5 1485C4P 4x4 1485D4P 6x6 1485E4P 8x8 One flat sealing plate included 45° Elbow Outside Opening 90° Elbow Outside Opening J 4.25 5.00 6.00 7.00 6.00 Part No. Size 1485B9Q 2.5 x 2.5 1485C9Q 4x4 1485D9Q 6x6 1485E9Q 8x8 1485F9Q 12 x 6 One flat sealing plate included J 4.25 5.00 6.00 7.00 6.00 All dimensions in inches unless specified otherwise Quality Products. Service Excellence. © Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 Wireway & Trough 45° Elbow Top Opening USA: 716.630.7030 Data Subject to change without notice 278 www.hammondmfg.com 1485 Series Lay-In Wireway - NEMA 12 Wireway & Trough Clockwise Tee Fitting Top Opening Tee Fitting Outside and Top Opening Part No. Size H 1485BTN 2.5 x 2.5 8.50 1485CTN 4x4 10.00 1485DTN 6x6 12.00 1485ETN 8x8 14.00 1485FTN 12 x 6 18.00 Two flat sealing plates included Part No. Size H 1485BTQ 2.5 x 2.5 8.50 1485CTQ 4x4 10.00 1485DTQ 6x6 12.00 1485ETQ 8x8 14.00 Two flat sealing plates included M 4.25 5.00 6.00 7.00 9.00 M 4.25 5.00 6.00 7.00 Counter-Clockwise Lay-In Wireway 12" Transposition Sections Clockwise & Counter-Clockwise • Used to rotate the open side of a wireway run by 90° and maintain the lay-in feature Reducers Box Connector • Use inside box when entering with "Lay-In" Wireway. Part No. Reduces from 1485CRE 4x4 1485DRE 6x6 1485ERE 8x8 1485FREC 12 x 6 1485FRED 12 x 6 to 2.5 x 2.5 4x4 6x6 4x4 6x6 Part No. Size E 1485BK 2.5 x 2.5 3.87 1485CK 4x4 5.37 1485DK 6x6 7.62 1485EK 8x8 9.62 1485FK 12 x 6 13.62 One angled sealing plate included Technical references and CAD downloads available at www.hammondmfg.com 279 Clockwise CounterPart No. Clockwise Part No. 1485BZ12 1485BZC12 1485CZ12 1485CZC12 1485DZ12 1485DZC12 1485EZ12 1485EZC12 One flat sealing plate included Size 2.5 x 2.5 4x4 6x6 8x8 G 3.87 5.37 7.62 9.62 7.62 All dimensions in inches unless specified otherwise Quality Products. Service Excellence. © Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 USA: 716.630.7030 Data Subject to change without notice www.hammondmfg.com 1485 Series Lay-In Wireway - NEMA 12 Bracket Hanger Cover Plate Part No. Size T U 1485BL1 2.5 x 2.5 9.25 4.50 1485CL1 4x4 11.75 6.00 1485DL1 6x6 15.25 8.12 1485EL1 8x8 20.56 12.12 Does not meet CSA or UL requirements Part No. Size R W 1485BL2 2.5 x 2.5 4.62 4.37 1485CL2 4x4 6.12 5.87 1485DL2 6x6 8.25 7.87 1485EL2 8x8 10.25 9.87 Does not meet CSA or UL requirements Part No. Size E 1485BH 2.5 x 2.5 3.87 1485CH 4x4 5.37 1485DH 6x6 7.62 1485EH 8x8 9.62 1485FH 12 x 6 13.62 One angled sealing plate included Maintains ratings on CSA and UL approved wireway G 3.87 5.37 7.62 9.62 7.62 Wireway & Trough Drop Hanger Junction Box • Includes inner panel. Technical references and CAD downloads available at www.hammondmfg.com N 12.00 14.00 16.00 18.00 P 10.25 13.87 17.87 21.87 Panel Size 8.75 x 6.87 10.75 x 8.87 12.75 x 10.87 14.75 x 12.87 All dimensions in inches unless specified otherwise Quality Products. Service Excellence. © Hammond Manufacturing Canada: 519.822.2960 or 905.456.3770 Lay-In Wireway Part No. Size 1485BJ 2.5 x 2.5 1485CJ 4x4 1485DJ 6x6 1485EJ 8x8 One flat sealing plate included USA: 716.630.7030 Data Subject to change without notice 280