PLA190 Single Pole, Normally Open OptoMOS® Relay INTEGRATED CIRCUITS DIVISION Parameter Blocking Voltage Load Current On-Resistance (max) Rating 400 150 22 Units VP mArms / mADC Features Description The PLA190 is a 400V, single-pole, normally open (1-Form-A) solid state relay that uses optically coupled relay technology to provide an enhanced 5000Vrms isolation barrier between the input and output of the relay. Its optically coupled outputs, which use the patented OptoMOS architecture, are controlled by a highly efficient GaAIAs infrared LED. • 5000Vrms Input/Output Isolation • Low Drive Power Requirements (TTL/CMOS Compatible) • No Moving Parts • High Reliability • Arc-Free With No Snubbing Circuits • FCC Compatible • VDE Compatible • No EMI/RFI Generation • Small 6-Pin Package • Machine Insertable, Wave Solderable • Surface Mount Tape & Reel Version Available Approvals • UL Recognized Component: File E76270 • CSA Certified Component: Certificate 1175739 • EN/IEC 60950-1 Certified Component: TUV Certificate B 09 07 49410 004 Ordering Information Applications • Telecommunications • Telecom Switching • Tip/Ring Circuits • Modem Switching (Laptop, Notebook, Pocket Size) • Hook Switch • Dial Pulsing • Ground Start • Ringing Injection • Instrumentation • Multiplexers • Data Acquisition • Electronic Switching • I/O Subsystems • Meters (Watt-Hour, Water, Gas) • Medical Equipment—Patient/Equipment Isolation • Security Systems • Aerospace • Industrial Controls Part Number PLA190 PLA190S PLA190STR Description 6-Pin DIP (50/Tube) 6-Pin Surface Mount (50/Tube) 6-Pin Surface Mount (1,000/Reel) Pin Configuration AC/DC Configuration + Control - Control NC 1 6 2 5 3 4 Load Do Not Use Load DC-Only Configuration + Control - Control NC 1 6 2 5 3 4 + Load - Load Switching Characteristics of Normally Open Devices Form-A IF 90% 10% ILOAD Pb DS-PLA190-R04 ton e3 www.ixysic.com toff 1 INTEGRATED CIRCUITS DIVISION PLA190 Absolute Maximum Ratings @ 25ºC Parameter Blocking Voltage Reverse Input Voltage Input Control Current Peak (10ms) Input Power Dissipation 1 Total Power Dissipation 2 Isolation Voltage, Input to Output Operational Temperature Storage Temperature 1 Derate linearly 1.33 mW / ºC 2 Derate linearly 6.67 mW / ºC Ratings 400 5 50 1 150 800 5000 -40 to +85 -40 to +125 Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Units VP V mA A mW mW Vrms °C °C Electrical Characteristics @ 25ºC Parameter Output Characteristics Load Current (Continuous) AC/DC Configuration DC Configuration Peak Load Current On-Resistance AC/DC Configuration DC Configuration Off-State Leakage Current Switching Speeds Turn-On Turn-Off Output Capacitance Input Characteristics Input Control Current to Activate Input Control Current to Deactivate Input Voltage Drop Reverse Input Current Common Characteristics Input to Output Capacitance 2 Conditions Symbol Min Typ Max Units - IL - - 150 250 ±400 mArms / mADC mADC mAP t=10ms ILPK - 22 7 1 ILEAK - VL=50V, f=1mHz ton toff COUT - 25 1 0.5 - IL=150mA IF=5mA VR=5V IF IF VF IR 0.4 0.9 - 0.7 1.2 - 5 1.4 10 mA mA V µA - CI/O - 3 - pF IF=150mA IF=250mA VL=400VP RON IF=5mA, VL=10V www.ixysic.com A ms pF R04 INTEGRATED CIRCUITS DIVISION PLA190 PERFORMANCE DATA @ 25ºC (Unless Otherwise Noted) * Typical LED Forward Voltage Drop (N=50, IF=5mA) 35 20 15 10 0 15 10 1.24 1.25 1.26 1.27 LED Forward Voltage (V) 30 0.24 0.26 0.28 0.30 0.32 0.34 Turn-On Time (ms) 0.11 10 5 15 10 0.45 0.55 0.65 0.75 LED Current (mA) 13.9 Typical LED Forward Voltage Drop vs. Temperature 1.2 1.1 -40 IF=10mA IF=5mA 460 0.5 0.4 0.3 0.2 0 0 20 40 60 Temperature (ºC) 80 0.45 485 0.142 0.140 0.138 0.136 0.134 0.132 0 100 465 470 475 480 Blocking Voltage (VP) Typical Turn-Off Time vs. LED Forward Current (IL=30mA) 0.144 0.1 -20 10 14.5 Typical Turn-On Time vs. LED Forward Current (IL=30mA) 0.7 Typical IF for Switch Operation vs. Temperature (IL=100mA) 0.65 14.1 14.2 14.3 14.4 On-Resistance (:) Turn-Off Time (ms) IF=50mA IF=20mA 1.4 1.3 14.0 0.6 1.5 15 0 0.85 Turn-On Time (ms) 1.6 0.35 20 5 0 0.25 0.17 25 20 5 0 0.13 0.14 0.15 0.16 Turn-Off Time (ms) 30 Device Count (N) Device Count (N) 15 0.12 Typical Blocking Voltage Distribution (N=50) 25 20 10 0.36 Typical On-Resistance Distribution (N=50, IF=5mA, IL=150mA) 30 25 15 0 1.28 Typical IF for Switch Operation (N=50, IL=150mA) 20 5 0 1.23 Device Count (N) 20 5 5 LED Forward Voltage (V) 25 Device Count (N) 25 Typical Turn-Off Time (N=50, IF=5mA, IL=150mA) 30 25 Device Count (N) Device Count (N) 30 10 20 30 40 LED Forward Current (mA) 50 0 Typical Turn-On Time vs. Temperature (IF=5mA, IL=80mA) 0.18 10 20 30 40 LED Forward Current (mA) 50 Typical Turn-Off Time vs. Temperature (IF=5mA, IL=80mA) 0.55 0.50 0.45 Turn-Off Time (ms) 0.17 0.60 Turn-On Time (ms) LED Current to Operate (mA) Typical Turn-On Time (N=50, IF=5mA, IL=150mA) 30 0.40 0.35 0.30 0.16 0.15 0.14 0.13 0.12 0.11 0.40 -40 -20 0 20 40 60 Temperature (ºC) 80 100 0.25 -40 -20 0 20 40 60 Temperature (ºC) 80 100 0.10 -40 -20 0 20 40 60 Temperature (ºC) 80 100 *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R04 www.ixysic.com 3 INTEGRATED CIRCUITS DIVISION PLA190 PERFORMANCE DATA @ 25ºC (Unless Otherwise Noted) * 150 17 100 15 14 13 12 11 -40 -20 0 20 40 60 Temperature (ºC) 80 100 50 0 -50 -100 -150 -2.0 -1.5 -1.0 260 490 250 485 240 230 220 210 200 190 80 120 110 -40 100 460 1.0 Load Current (A) 9 465 170 20 40 60 Temperature (ºC) 130 2.0 470 450 -40 0 1.5 475 455 -20 140 100 -0.5 0.0 0.5 1.0 Load Voltage (V) 480 180 -40 150 Typical Blocking Voltage vs. Temperature Blocking Voltage (VP) Load Current (mA) Maximum Load Current vs. Temperature DC-Only Configuration (IF=5mA) 160 Leakage Current (nA) 16 Maximum Load Current vs. Temperature AC/DC Configuration (IF=5mA) Typical Load Current vs. Load Voltage (IF=5mA) Load Current (mA) 18 Load Current (mA) On-Resistance (:) Typical On-Resistance vs. Temperature (IF=5mA, IL=100mA) -20 0 20 40 60 Temperature (ºC) 80 100 -20 0 20 40 60 Temperature (ºC) 80 100 Leakage Current vs. Temperature Measured Across Pins 5&6 (VL=400V) 8 7 6 5 4 3 -40 -20 0 20 40 60 Temperature (ºC) 80 100 Energy Rating Curve, Single Pole (IF=5mA) 0.8 0.6 0.4 0.2 0.0 10Ps 100Ps 1ms 10ms 100ms Time 1s 10s 100s *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.ixysic.com R04 INTEGRATED CIRCUITS DIVISION PLA190 Manufacturing Information Moisture Sensitivity All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according to the limitations and information in that standard as well as to any limitations set forth in the information or standards referenced below. Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product performance, reduction of operable life, and/or reduction of overall reliability. This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033. Device Moisture Sensitivity Level (MSL) Rating PLA190 / PLA190S MSL 1 ESD Sensitivity This product is ESD Sensitive, and should be handled according to the industry standard JESD-625. Reflow Profile This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020 must be observed. Device Maximum Temperature x Time PLA190 / PLA190S 250ºC for 30 seconds Board Wash IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be used. Pb R04 e3 www.ixysic.com 5 INTEGRATED CIRCUITS DIVISION PLA190 Mechanical Dimensions PLA190 8.382 ± 0.381 (0.330 ± 0.015) PCB Hole Pattern 7.239 TYP (0.285 TYP) 2.54 ± 0.127 (0.100 ± 0.005) 6 - 0.800 DIA. (6 - 0.031 DIA.) 9.144 ± 0.508 (0.360 ± 0.020) 6.350 ± 0.127 (0.250 ± 0.005) 2.540 ± 0.127 (0.100 ± 0.005) 7.620 ± 0.127 (0.300 ± 0.005) Pin 1 7.620 ± 0.254 (0.300 ± 0.010) 1.651 ± 0.254 (0.065 ± 0.010) 3.302 ± 0.051 (0.130 ± 0.002) 0.254 ± 0.0127 (0.010 ± 0.0005) 6.350 ± 0.127 (0.250 ± 0.005) 5.080 ± 0.127 (0.200 ± 0.005) 4.064 TYP (0.160 TYP) Dimensions mm (inches) 0.457 ± 0.076 (0.018 ± 0.003) PLA190S 8.382 ± 0.381 (0.330 ± 0.015) 9.524 ± 0.508 (0.375 ± 0.020) Pin 1 0.635 ± 0.127 (0.025 ± 0.005) PCB Land Pattern 2.54 ± 0.127 (0.100 ± 0.005) 2.54 (0.10) 6.350 ± 0.127 (0.250 ± 0.005) 0.457 ± 0.076 (0.018 ± 0.003) 1.651 ± 0.254 (0.065 ± 0.010) 7.620 ± 0.254 (0.300 ± 0.010) 0.254 ± 0.0127 (0.010 ± 0.0005) 8.90 (0.3503) 1.65 (0.0649) 0.65 (0.0255) 3.302 ± 0.051 (0.130 ± 0.002) 4.445 ± 0.254 (0.175 ± 0.010) Dimensions mm (inches) 1.651 ± 0.254 (0.065 ± 0.010) 6 www.ixysic.com R04 INTEGRATED CIRCUITS DIVISION PLA190 PLA190STR Tape & Reel 330.2 Dia (13.00 Dia) Top Cover Tape Thickness 0.102 Max (0.004 Max) W=16.00 (0.63) B0 = 10.10 (0.398) K0 = 4.90 (0.19) K1 = 3.80 (0.15) P = 12.00 (0.472) User Direction of Feed Embossed Carrier Embossment A0 = 10.10 (0.398) Dimensions mm (inches) NOTES: 1. All dimensions carry tolerances of EIA Standard 481-2 2. The tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2 For additional information please visit our website at: www.ixysic.com IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice. 7 Specification: DS-PLA190-R04 ©Copyright 2012, IXYS Integrated Circuits Division OptoMOS® is a registered trademark of IXYS Integrated Circuits Division All rights reserved. Printed in USA. 12/22/2012