OSEP Nemi Whisker Evaln SOIC 8L

Orient Semiconductor Electronics Philippines, Inc.
6 Ring Road, Light Industry & Science Park II, Brgy. Lamesa, Calamba, Laguna
OSEP
NEMI Whisker Test Study
for SOIC 8L Package
(Sept. 16, 2003 NEMI Revision 4.5)
QRA Department - CQE Section
Reliability Group
Orient Semiconductor Electronics Philippines, Inc.
6 Ring Road, Light Industry & Science Park II, Brgy. Lamesa, Calamba, Laguna
OSEP NEMI Whisker Test for SOIC Package
1
Scope
This evaluation addresses NEMI’s three different test
condition requirement for evaluating whisker growth
i.e. two isothermal storage conditions and one
temperature cycling condition.
2
Purpose
To evaluate and monitor the propensity of Matte Tin
plating to grow whisker for various conditions after
assembly.
The long term reliability of electronic assemblies can be
compromised by electrical shorting that may be induced
by metal whisker formations that have been known to
occur in, but are not limited to, platings with high tin
content.
QRA Department - CQE Section
Reliability Group
Orient Semiconductor Electronics Philippines, Inc.
6 Ring Road, Light Industry & Science Park II, Brgy. Lamesa, Calamba, Laguna
3
Test Equipment
3.1
Scanning Electronic Microscope
SEM is used to make observations with a magnification
capability of 100, 3kX then take photos of the test specimen.
SEM Supplier : HITACH
Model
: S-3500N
3.2
Temperature Cycling Equipment
An air-to-air two chamber temperature oven which is capable of
cycling from -80 to +200°C temperature.
Supplier
: Votsch
Model
: VT 7012 S2
3.3 Temperature Humidity Storage
A temperature/humidity storage chamber which is capable of 30
to 100°C, 40 ~100% Relative Humidity environments.
Supplier
: Votsch
Model
: VC 2033
QRA Department - CQE Section
Reliability Group
Orient Semiconductor Electronics Philippines, Inc.
6 Ring Road, Light Industry & Science Park II, Brgy. Lamesa, Calamba, Laguna
4
Test Conditions
The condition below defines three separate environmental
stresses in which parts must be tested to generate whiskers
on the test components.
4.1
Ambient conditions
Test condition: 25±5°C; 30~80% RH
Duration: 5000 hours
4.2 Temperature and Humidity Soak
Test condition: 85°C; 85 % RH
Duration: 6 months
4.3 Temperature Cycling Test
Test condition: -55+0/-10°C to 85+10/-0 °C; 10 min. dwell time
Duration: 1000 cycles
QRA Department - CQE Section
Reliability Group
Orient Semiconductor Electronics Philippines, Inc.
6 Ring Road, Light Industry & Science Park II, Brgy. Lamesa, Calamba, Laguna
5
Evaluation Results
5.1 After 5000H Ambient condition Exposure
Suspected mounds were found on all samples. Refer to below SEM photo.
Approx. Measurement is 3.02 µm
QRA Department - CQE Section
Approx. Measurement is 6.42 µm
Approx. Measurement is 10.26 µm
Reliability Group
Orient Semiconductor Electronics Philippines, Inc.
6 Ring Road, Light Industry & Science Park II, Brgy. Lamesa, Calamba, Laguna
5.2
After 5000H Temperature and Humidity Soak
Whisker formation were found after 5000H Temperature and humidity soak
with a maximum measurement of approximately 15.19µm which is still acceptable
base on NEMI 40µm requirement. Refer to below SEM photo.
QRA Department - CQE Section
Reliability Group
Orient Semiconductor Electronics Philippines, Inc.
6 Ring Road, Light Industry & Science Park II, Brgy. Lamesa, Calamba, Laguna
5.3
After 1000 cycles Temp. Cycle Test
Whisker formation were found after 1000 cycles TCT with a maximum
measurement of approximately 23.5µm which is still acceptable base on NEMI
40µm requirement. Refer to below SEM photo.
QRA Department - CQE Section
Reliability Group