Product Series Output Load VCXO (Voltage Controlled Crystal Oscillator) G576 CMOS Square Wave 15 pF MERCURY Since 1973 ● RoHS compliant and Pb-free product ● Ideal choice of fundamental frequency range VCXOs (<55 MHz). ● Low cost and high performance. ● Phase noise < 132 dBc/Hz at 1 KHz offset. ● Ideal for set-top boxes, MPEG and telecommunicnations. Absolute Maximum Ratings: Parameter Supply Voltage Input Pin Voltage Power Dissipation Min. -0.3 V D.C. Max. +5.5 V D.C. VSS -0.3 V D.C. VDD+0.3 V D.C. 100 mW Note VDD-VSS Environmental Performance Specifications 80% wave from 50%VDD VOL T Duty Cycle = (TH / T) x100% MERCURY 3G576 5G576 0 -30 -50 -70 -90 -110 -130 -150 Control Voltage 0.3 V 0.5 V 20% wave form TH +150 +130 +110 +90 +70 +50 +30 (postive transfer) 4.5 V VOH Frequency Deviation CMOS 3.0 V Tf 2.5 V Tr 1.65 V Output Waveform: RoHS Compliant and Pb (lead) free 260°C for 10 sec. IPC/JEDEC J-STD-020C Level 1 85% RH, 85°C, 48 hours Leak rate 2x10-8 ATM-cm3/sec max. MIL-STD-883F method 203.8 MIL-STD-883E method 1010 MIL-STD-202G method 210F MIL-STD-202F, method 215J MIL-STD-883F method 2007.3A, MIL-STD-883F method 2002.3 B, 2 KV max. Human body model. -55°C to +125°C Freq. Deviation (ppm) RoHS Status Reflow Moisture Sensitivity Level Humidity Gross and Fine Leak Solderability Temperature Cycling Resistance to Soldering Heat Resistance to Solvents Vibration Shock ESD Rating Storage Temperature www.mercury-crystal.com Taiwan: TEL (886)-2-2406-2779, FAX (886)-2-2496-0769, e-mail: [email protected] U.S.A.: TEL (1)-909-466-0427, FAX (1)-909-466-0762, e-mail: [email protected] MERCURY Page 1 of 3 Date: Oct. 1, 2006 Rev. 0 General Specifications TA=+25°C, at specified voltage, CL=15 pF Product Series Input Voltage (VDD) Frequency Range Circuit Design Package Type Initial Frequency Accuracy (at+25°C) Output Voltage HIGH “1” Output Voltage LOW “0” (1) Frequency Stability Commercial Temperature Range (code “C”) Industrial Temperature Range (code “I”) Current Consumption Output Load Rise Time (Tr) and Fall Time (Tf) Voltage Control Characteristics (pad No. 1) Duty Cycle Start-up Time (Ts) Control Voltage Range Control Voltage Center (Vc) Frequency Deviation Range Linearity Slope Polarity (Transfer Function) Positive: Increasing control voltage increases output frequency. Modulation Bandwidth Input Impedance Tri-State Control Characteristics Aging Phase Noise Offset dBc/Hz Integrated Phase Jitter Period Jitter – RMS Period Jitter – peak to peak Packaging G576 VDD = +3.3 V D.C. ±10% VDD = +5.0 V D.C. ±10% Voltage code is“3” Voltage code is “5” 0.625 MHz ~ 45 MHz 1.25MHz ~ 55.2 MHz Fundamental mode crystal used. No PLL. 6 pad ceramic leadless SMD. 5x7x1.8 mm. To tune to the nominal frequency To tune to the nominal frequency with control voltage Vc = 1.65V±0.2V with control voltage Vc =2.5V±0.2V 90% of VDD min. 10% of VDD max. “A”: ±25 ppm over 0°C to +70°C “B”:±50 ppm over 0°C to +70°C “C”:±100 ppm over 0°C to +70°C For non-standard please specify desired frequency stability after the “C”. For example “C20” is ±20 ppm over 0 to +70°C “D”:±25 ppm over -40°C to +85°C “E”:±50 ppm over -40°C to +85°C “F”:±100 ppm over -40°C to +85°C For non-standard please specify desired frequency stability after the “I”. For example “I20” is ±20 ppm over -40 to +85°C 10 mA max. 15 mA max. 15 pF 10 n Sec. max; 4 n Sec. typical. Measured between 20% and 80% of the wave form. 45% min. 55 % max. (measured at 50% of wave form) 10 m Sec. max. 3 m Sec. typical +0.3 V to +3.0 V +0.5 V to +4.5 V +1.65 V +2.5 V From ±30 ppm to ±120 ppm. From ±30 ppm to ±150 ppm. To define the deviation range please use “N” for minimum (no less than the deviation specified); “M” for maximum (no more than the deviation specified) “T” for typical (±20% of the range specified). 10% max.; 6% typical 10 kHz min. measured at -3 dB with Vcon=1.65V for 3G576 and Vcon=2.5V for 5G576 1 MΩ. typical Output is enabled when no connection or ≥1.6 V is applied to pad 2 or pad 5 Output is disabled and high impedance when ≤0.55 V is applied to pad 2 or pad 5. Pad 2 and pad 5 are internally connected. ±5 ppm per year max. 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz -70 -105 -132 -142 -145 -150 1 ps max. 12 KHz ~20 MHz 2 ps typical 14 ps typical 180 mm reel, 16 mm tape, 1000 pcs per reel. (1) Inclusive of 25°C calibration tolerance, stability over operating temperature range, ±10% supply voltage variation, ±10% load variation, aging, shock and vibration. MERCURY Page 2 of 3 Date: Oct.1, 2006 Rev. 0 Part Number Format and Example: Example: 3G576A-100N-35.328 Explanation: +3.3V G576 series VCXO, 35.328 MHz, frequency stability is ±25 ppm over 0°C to +70°C, frequency deviation range is ±100 ppm minimum. ": customer to specify " " " " " 3 G576 A — 100 N — 35.328 n o p q r s n: Voltage code: “3” for +3.3 V; o: G576 product series p: Frequency stability code: “A” ~ “F” or custom. See table above. q: Frequency deviation range in ppm; r: Deviation range code: “N” is minimum; “M” for maximum; “T” for typical (±20%); s: VCXO Frequency in MHz G576 Test Circuit Frequency counter A 6 + + - - V 1 1.0 uF Vcc 4 5 Oscilloscope G576 MEC 2 3 15 pF + V control - 2.54[0.100] MEC 3 1.8±0.1 [0.070 ± 0.004] 2 Pad 1 Control Voltage Pad 4 Output Pad 2 Tri-State Pad 5 Tri-State Pad 3 Ground Pad 6 Supply Voltage [0.004] 0.1 [0.049] 1.25 G576 1 [0.055] 1.4 0.6[0.024] 4 6 5R 0. 7 2 3 1 5.08 [0.200] typical bottom view 1.5[0.059] 1.8[0.071] [0.275±0.006] 7.00±0.15 5 6 4 2.0[0.079] [0.197± 0.006] 5.00±0.15 Package Dimensions and suggested Pad Layout:: unit: mm [inches] For proper power line filtering, a 0.01 uF ceramic decoupling capacitor is required between the VDD and ground. For better performance, add a 0.1 uF tantalum capacitor in parallel with the 0,01 uF. Pad 2 and pad 5 are internally connected 5.08 [0.200] Rounded pad is pad No. 1. Count counter-clockwise when looking at top view. Count clockwise when looking at bottom view. MERCURY Page 3 of 3 Date: Oct.1, 2006 Rev. 0