MD100x-xxRW Datasheet

MD100RW Series
Wide 2:1 Input, 1W SIP
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
• Miniature SIP Case
• Wide 2:1 Input Range
• Single & Dual Outputs
• 1,500 VDC Isolation
• >2.8 MHour MTBF
• 24 Standard Models
• Industry Standard Pin-Out
Input
Parameter
Conditions
Input Voltage Range
Startup Threshold Voltage
Input Filter
Min.
5 VDC Input
4.5
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
Internal Capacitor
Typ.
5.0
12.0
24.0
48.0
Max.
9.0
18.0
36.0
75.0
4.5
9.0
18.0
36.0
Units
Max.
±1.0
Units
%
%
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Line Regulation
Conditions
Load Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Min.
VIN = Min to Max
Single Output
IOUT = 5% to 100%
Dual Output
Single Output
IOUT = 10% to 90%
Dual Output
See Note 1
Typ.
±1.2
±1.0
±1.0
±0.5
±0.8
50
250
±2.5
See Note 2
±5.0
±0.02
%
mV P - P
mSec
%
%/ºC
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
50
220
Units
VDC
M
pF
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling, See Note 3
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-55
Free Air Convection
RH, Non-condensing
Max.
+85
+105
+125
Units
ºC
ºC
ºC
95
%
See Mechanical Drawing (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.07 Oz (2.1g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
2.8
Typ.
Max.
Units
MHours
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
15
25
50
100
260
Units
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Model
Number
MD105S-05RW
MD105S-12RW
MD105S-15RW
MD105S-24RW
MD105D-12RW
MD105D-15RW
MD112S-05RW
MD112S-12RW
MD112S-15RW
MD112S-24RW
MD112D-12RW
MD112D-15RW
MD124S-05RW
MD124S-12RW
MD124S-15RW
MD124S-24RW
MD124D-12RW
MD124D-15RW
MD148S-05RW
MD148S-12RW
MD148S-15RW
MD148S-24RW
MD148D-12RW
MD148D-15RW
Input
Output
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
5
4.5 - 9.0
263
40
5
4.5 - 9.0
259
40
5
4.5 - 9.0
254
40
5
4.5 - 9.0
265
40
5
4.5 - 9.0
262
40
5
4.5 - 9.0
254
40
12
9.0 - 18.0
108
20
12
9.0 - 18.0
108
20
12
9.0 - 18.0
105
20
12
9.0 - 18.0
109
20
12
9.0 - 18.0
106
20
12
9.0 - 18.0
106
20
24
18.0 - 36.0
54
10
24
18.0 - 36.0
52
10
24
18.0 - 36.0
52
10
24
18.0 - 36.0
55
10
24
18.0 - 36.0
53
10
24
18.0 - 36.0
52
10
48
36.0 - 75.0
27
7.0
48
36.0 - 75.0
27
7.0
48
36.0 - 75.0
27
7.0
48
36.0 - 75.0
28
7.0
48
36.0 - 75.0
27
7.0
48
36.0 - 75.0
26
7.0
Notes:
1. When measuring output ripple & noise, it is recommended that an external
ceramic capacitor (0.1 µF typ.) be placed from the +VOUT to the -VOUT pins for
single output units and from each output to common for dual output models.
2. Transient recovery is measured to within a 1% error band for a load step
change of 25%.
3. Free air convection is typically 20 LFM. The units should not be operated in
still air (0 LFM).
4. Exceeding the absollute ratings could damage the unit.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
5.0
12.0
15.0
24.0
±12.0
±15.0
5.0
12.0
15.0
24.0
±12.0
±15.0
5.0
12.0
15.0
24.0
±12.0
±15.0
5.0
12.0
15.0
24.0
±12.0
±15.0
200
83
67
42
±42
±33
200
83
67
42
±42
±33
200
83
67
42
±42
±33
200
83
67
42
±42
±33
Fuse
Efficiency Capacitive
Rating
Load
(%, Typ)
Slow-Blow
(µF, Max)
(mA)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
76
77
79
76
77
78
77
77
80
77
79
78
77
80
80
77
80
80
77
78
78
76
79
79
1,680
820
680
470
±470
±330
1,680
820
680
470
±470
±330
1,680
820
680
470
±470
±330
1,680
820
680
470
±470
±330
500
500
500
500
500
500
250
250
250
250
250
250
120
120
120
120
120
120
60
60
60
60
60
60
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
-VIN
-VIN
2
+VIN
+VIN
4
+VOUT
+VOUT
5
No Pin
Common
6
-VOUT
-VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]