MD100RW Series Wide 2:1 Input, 1W SIP Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 1W Output Power • Miniature SIP Case • Wide 2:1 Input Range • Single & Dual Outputs • 1,500 VDC Isolation • >2.8 MHour MTBF • 24 Standard Models • Industry Standard Pin-Out Input Parameter Conditions Input Voltage Range Startup Threshold Voltage Input Filter Min. 5 VDC Input 4.5 12 VDC Input 9.0 24 VDC Input 18.0 48 VDC Input 36.0 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input Internal Capacitor Typ. 5.0 12.0 24.0 48.0 Max. 9.0 18.0 36.0 75.0 4.5 9.0 18.0 36.0 Units Max. ±1.0 Units % % VDC VDC Output Parameter Output Voltage Accuracy Line Regulation Conditions Load Regulation Ripple & Noise (20 MHz) Transient Recovery Time Transient Response Deviation Temperature Coefficient Output Short Circuit Min. VIN = Min to Max Single Output IOUT = 5% to 100% Dual Output Single Output IOUT = 10% to 90% Dual Output See Note 1 Typ. ±1.2 ±1.0 ±1.0 ±0.5 ±0.8 50 250 ±2.5 See Note 2 ±5.0 ±0.02 % mV P - P mSec % %/ºC Continuous (Autorecovery) General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions Min. 60 Seconds 1,500 500 VDC 1,000 100 kHz, 1V Typ. Max. 50 220 Units VDC M pF kHz Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling, See Note 3 Humidity Physical Case Size Case Material Weight Conditions Ambient Case Min. -40 Typ. +25 -55 Free Air Convection RH, Non-condensing Max. +85 +105 +125 Units ºC ºC ºC 95 % See Mechanical Drawing (Page 2) Non-Conductive Black Plastic (UL94-V0) 0.07 Oz (2.1g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. 2.8 Typ. Max. Units MHours Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. 15 25 50 100 260 Units Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC ºC www.micropowerdirect.com Model Selection Guide Model Number MD105S-05RW MD105S-12RW MD105S-15RW MD105S-24RW MD105D-12RW MD105D-15RW MD112S-05RW MD112S-12RW MD112S-15RW MD112S-24RW MD112D-12RW MD112D-15RW MD124S-05RW MD124S-12RW MD124S-15RW MD124S-24RW MD124D-12RW MD124D-15RW MD148S-05RW MD148S-12RW MD148S-15RW MD148S-24RW MD148D-12RW MD148D-15RW Input Output Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load 5 4.5 - 9.0 263 40 5 4.5 - 9.0 259 40 5 4.5 - 9.0 254 40 5 4.5 - 9.0 265 40 5 4.5 - 9.0 262 40 5 4.5 - 9.0 254 40 12 9.0 - 18.0 108 20 12 9.0 - 18.0 108 20 12 9.0 - 18.0 105 20 12 9.0 - 18.0 109 20 12 9.0 - 18.0 106 20 12 9.0 - 18.0 106 20 24 18.0 - 36.0 54 10 24 18.0 - 36.0 52 10 24 18.0 - 36.0 52 10 24 18.0 - 36.0 55 10 24 18.0 - 36.0 53 10 24 18.0 - 36.0 52 10 48 36.0 - 75.0 27 7.0 48 36.0 - 75.0 27 7.0 48 36.0 - 75.0 27 7.0 48 36.0 - 75.0 28 7.0 48 36.0 - 75.0 27 7.0 48 36.0 - 75.0 26 7.0 Notes: 1. When measuring output ripple & noise, it is recommended that an external ceramic capacitor (0.1 µF typ.) be placed from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output models. 2. Transient recovery is measured to within a 1% error band for a load step change of 25%. 3. Free air convection is typically 20 LFM. The units should not be operated in still air (0 LFM). 4. Exceeding the absollute ratings could damage the unit. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Voltage Current Current (VDC) (mA, Max) (mA, Min) 5.0 12.0 15.0 24.0 ±12.0 ±15.0 5.0 12.0 15.0 24.0 ±12.0 ±15.0 5.0 12.0 15.0 24.0 ±12.0 ±15.0 5.0 12.0 15.0 24.0 ±12.0 ±15.0 200 83 67 42 ±42 ±33 200 83 67 42 ±42 ±33 200 83 67 42 ±42 ±33 200 83 67 42 ±42 ±33 Fuse Efficiency Capacitive Rating Load (%, Typ) Slow-Blow (µF, Max) (mA) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 76 77 79 76 77 78 77 77 80 77 79 78 77 80 80 77 80 80 77 78 78 76 79 79 1,680 820 680 470 ±470 ±330 1,680 820 680 470 ±470 ±330 1,680 820 680 470 ±470 ±330 1,680 820 680 470 ±470 ±330 500 500 500 500 500 500 250 250 250 250 250 250 120 120 120 120 120 120 60 60 60 60 60 60 Derating Curve Mechanical Dimensions Pin Connections Pin Single Dual 1 -VIN -VIN 2 +VIN +VIN 4 +VOUT +VOUT 5 No Pin Common 6 -VOUT -VOUT Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) • Pin 1 is marked by a “dot” or indentation on the side of the unit MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]