Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
• Compact “MiniDIP” Case
Input
Parameter
Conditions
Input Voltage Range
• EN 60950 Approved (UL)
• Single & Dual Outputs
• 1,000 VDC Isolation
• >3.5 MHour MTBF
• 24 Standard Models
• LOWEST COST!!
Input Filter
Reverse Polarity Input Current
Min.
Typ.
5 VDC Input
4.5
5.0
12 VDC Input 10.8
12.0
24 VDC Input 21.6
24.0
Internal Capacitor
Max.
5.5
13.2
26.4
Units
0.3
A
Max.
±3.0
±1.0
Units
%
%
%
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±1.0
Dual Output , Balanced Loads
±0.1
For Vin Change of 1%
±1.2
See Model Selection Guide
Single Output, See Note 3
75
Dual Output, See Note 3
50
120
±0.02
Momentary (1.0 Sec.)
100
750
±0.03
mV P - P
%
%/ºC
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Max.
+85
+125
Units
ºC
ºC
95
%
60
100
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
MicroPower Direct
Reliability Specifications
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
MTBF
Safety Standards
Safety Approvals
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Absolute Maximum Ratings
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
0.79 x 0.39 x 0.28 Inches (20.0 x 10.0 x 7.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.07 Oz (2.1g)
Conditions
Min.
Typ.
MIL HDBK 217F, 25ºC, Gnd Benign
3.5
UL 1950, EN 60950
UL, cUL; File No. E245422
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
Typ.
Max.
Units
MHours
Max.
9.0
18.0
30.0
300
450
Units
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
mW
www.micropowerdirect.com
Model Selection Guide
Model
Number
G101E
G102E
G103E
G104E
G105E
G106E
G107E
G108E
G111E
G112E
G113E
G114E
G115E
G116E
G117E
G118E
G121E
G122E
G123E
G124E
G125E
G126E
G127E
G128E
Input
Voltage (VDC)
Current (mA)
Voltage
Nominal
Range
Full-Load No-Load (VDC)
5
4.5 - 5.5
286
30
5.0
5
4.5 - 5.5
256
30
9.0
5
4.5 - 5.5
256
30
12.0
5
4.5 - 5.5
250
30
15.0
5
4.5 - 5.5
278
30
±5.0
5
4.5 - 5.5
260
30
±9.0
5
4.5 - 5.5
253
30
±12.0
5
4.5 - 5.5
250
30
±15.0
12
10.8 - 13.2
117
15
5.0
12
10.8 - 13.2
109
15
9.0
12
10.8 - 13.2
107
15
12.0
12
10.8 - 13.2
105
15
15.0
12
10.8 - 13.2
116
15
±5.0
12
10.8 - 13.2
107
15
±9.0
12
10.8 - 13.2
105
15
±12.0
12
10.8 - 13.2
107
15
±15.0
24
21.6 - 26.4
57
8
5.0
24
21.6 - 26.4
53
8
9.0
24
21.6 - 26.4
53
8
12.0
24
21.6 - 26.4
52
8
15.0
24
21.6 - 26.4
57
8
±5.0
24
21.6 - 26.4
52
8
±9.0
24
21.6 - 26.4
52
8
±12.0
24
21.6 - 26.4
52
8
±15.0
Output
Current
Current
Load
Regulation
(mA, Max)
(mA, Min)
(%, Max)
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
200.0
111.0
83.0
67.0
±100.0
±56.0
±42.0
±33.0
200.0
111.0
83.0
67.0
±100.0
±56.0
±42.0
±33.0
200.0
111.0
83.0
67.0
±100.0
±56.0
±42.0
±33.0
Efficiency Fuse Rating
Slow-Blow
(%, Typ)
(mA)
70
78
78
80
72
77
79
80
71
76
78
79
72
78
79
78
73
78
78
79
73
79
80
80
500
500
500
500
500
500
500
500
200
200
200
200
200
200
200
200
100
100
100
100
100
100
100
100
Derating Curve
Other input/output combinations are available
(i.e. 3.3 VDC). Contact the factory for details at:
[email protected]
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. These units should not be operated with a load under 10% of full load. Operation at no-load
may cause damage to the unit.
3. These converters will operate without external components. However, when measuring output
ripple, it is recommended that an external ceramic capacitor be placed from the +Vout pin to the
-Vout pin for single output
units and from each outOutput Capacitor
Input
Vin
Vout
put to common for dual
Capacitor
Single
Dual
output units. An input
4.7 µF
5 VDC 10.0 µF 4.7 µF
capacitor will enhance 5 VDC
stability over temperature 12 VDC
2.2 µF
9 VDC 4.7 µF
2.2 µF
and input line variations.
24
VDC
1.0
µF
12
VDC
2.2
µF
1.0 µF
Recommended capacitor
15 VDC 1.0 µF 0.47 µF
values are given in the
table above. For applications requiring very low output noise levels, a simple LC filter should be effective.
4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output. To do this,
connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output
common.
5. It is recommended that a fuse be used on the input of a power supply for protection. See the
Model Selection table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin Single
Dual
1
-Vin
-Vin
7
NC
NC
8
-Vout Common
NC = No Connection
Pin Single
Dual
9
11
14
+Vout
-Vout
+Vin
+Vout
No Pin
+Vin
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]