G200E Series Low Cost, 2W Compact MiniDIP DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input • 2W Output Power • Miniature SIP Case • UL Approved (File E245422) • Single & Dual Outputs • 1,000 VDC Isolation • >3.5 MHour MTBF • 24 Standard Models • LOWEST COST!! Parameter Input Voltage Range Conditions Min. Typ. Max. 5 VDC Input 4.5 5.0 5.5 12 VDC Input 10.8 12.0 13.2 24 VDC Input 21.6 24.0 26.4 Input Filter VDC Internal Capacitor Reverse Polarity Input Current 0.3 A Max. Units Output Parameter Conditions Min. Typ. Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation ±2.5 % Dual Output , Balanced Loads ±1.0 % For Vin Change of 1% ±1.2 % See Model Selection Guide Ripple & Noise (20 MHz) Output Power Protection 100 150 mV P - P ±0.02 ±0.03 %/ºC Max. Units 120 Temperature Coefficient RoHS Compliant Units Output Short Circuit % Momentary (1.0 Sec.) General Parameter Conditions Isolation Voltage Isolation Resistance Isolation Capacitance Min. 60 Seconds 1,000 500 VDC 1,000 100 kHz, 1V Switching Frequency Typ. VDC MΩ 60 pF 75 kHz Environmental Parameter Conditions Operating Temperature Range Ambient Storage Temperature Range Typ. Max. -40 +25 +85 ºC +125 ºC 95 % -55 Cooling Humidity Min. Units Free Air Convection RH, Non-condensing Physical MicroPower Direct Case Size (5V 12V & 24V Input Models) 292 Page Street Suite D Stoughton, MA 02072 USA Weight T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com 0.8 x 0.40 x 0.32 Inches (20.4 x 10.2 x 8.2 mm) Case Material Non-Conductive Black Plastic (UL94-V0) 0.07 Oz (2.1g) Reliability Specifications Parameter MTBF Conditions Min. MIL HDBK 217F, 25ºC, Gnd Benign Typ. Max. 3.5 Units MHours Safety Standards UL 1950, EN 60950, IEC 60950 Safety Approvals UL, cUL; File No. E245422 Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Conditions Min. Typ. Max. 5 VDC Input -0.7 9.0 12 VDC Input -0.7 18.0 24 VDC Input -0.7 30.0 Units VDC 1.5 mm From Case For 10 Sec 300 ºC All Models 450 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Input Output Load Voltage (VDC) Current (mA) Regulation Voltage Current Current Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) 5 4.5 - 5.5 494 30 5.0 400.0 40.0 15 5 4.5 - 5.5 488 30 9.0 222.0 23.0 15 5 4.5 - 5.5 476 30 12.0 167.0 17.0 15 5 4.5 - 5.5 476 30 15.0 133.0 14.0 15 5 4.5 - 5.5 488 30 ±5.0 ±200.0 ±20.0 15 5 4.5 - 5.5 482 30 ±9.0 ±111.0 ±12.0 15 5 4.5 - 5.5 470 30 ±12.0 ±83.0 ±9.0 15 5 4.5 - 5.5 470 30 ±15.0 ±67.0 ±7.0 15 12 10.8 - 13.2 203 15 5.0 400.0 40.0 15 12 10.8 - 13.2 201 15 9.0 222.0 23.0 15 12 10.8 - 13.2 196 15 12.0 167.0 17.0 15 12 10.8 - 13.2 196 15 15.0 133.0 14.0 15 12 10.8 - 13.2 201 15 ±5.0 ±200.0 ±20.0 15 12 10.8 - 13.2 198 15 ±9.0 ±111.0 ±12.0 15 12 10.8 - 13.2 194 15 ±12.0 ±83.0 ±9.0 15 12 10.8 - 13.2 194 15 ±15.0 ±67.0 ±7.0 15 24 21.6 - 26.4 100 8 5.0 400.0 40.0 15 24 21.6 - 26.4 99 8 9.0 222.0 23.0 15 24 21.6 - 26.4 97 8 12.0 167.0 17.0 15 24 21.6 - 26.4 97 8 15.0 133.0 14.0 15 24 21.6 - 26.4 99 8 ±5.0 ±200.0 ±20.0 15 24 21.6 - 26.4 98 8 ±9.0 ±111.0 ±12.0 15 24 21.6 - 26.4 96 8 ±12.0 ±83.0 ±9.0 15 24 21.6 - 26.4 96 8 ±15.0 ±67.0 ±7.0 15 Model Number G201E G202E G203E G204E G205E G206E G207E G208E G211E G212E G213E G214E G215E G216E G217E G218E G221E G222E G223E G224E G225E G226E G227E G228E Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. These units should not be operated with a load under 10% of full load. Operation at no-load may cause damage to the unit. 3. These converters will operate without external components. However, when measuring output ripple, it is recommended that an external ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. An input capacitor will enhance stability over temperature and input line variations. Recommended capacitor values are given in the table below. For applications requiring very low output noise levels, a simple LC filter should be effective. Output Capacitor Input Vin Vout Capacitor Single Dual 5 VDC 4.7 µF 5 VDC 10.0 µF 4.7 µF 12 VDC 2.2 µF 9 VDC 4.7 µF 2.2 µF 24 VDC 1.0 µF 12 VDC 2.2 µF 1.0 µF 15 VDC 1.0 µF 0.47 µF Efficiency (%, Typ) 81 82 84 84 82 83 85 85 82 83 85 85 83 84 86 86 83 84 86 86 84 85 87 87 Fuse Rating Slow-Blow (mA) 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 500 500 500 250 250 250 250 250 250 250 250 Derating Curve Mechanical Dimensions 4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Pin Connections Pin Single Dual Pin Single Dual 1 7 8 -Vin NC -Vout -Vin NC Common 9 11 14 +Vout No Pin +Vin +Vout -Vout +Vin Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the top of the unit MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]