MPD A313ERU

A300ERU Series
Low Cost, 4:1 Input 3W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 3W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• -40ºC to +85ºC Temp Range
• Compact DIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
• Industry Standard Pin-Out
• Low, Low Cost!
Input
Parameter
Conditions
Input Voltage Range (See Note 1)
Min.
Typ.
Max.
24 VDC Input
9.0
24.0
36.0
48 VDC Input
18.0
48.0
72.0
Input Filter
Units
VDC
Capacitors
Short Circuit Input Power
2,000
mW
Output
Parameter
Conditions
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Min.
See Note 2
Typ.
Max.
Units
±1.0
±3.0
%
%
Dual Output , Balanced Loads
±3.0
Vin = Min to Max
±0.2
±0.5
Iout = 10% to 100%
±0.5
±1.0
%
75
150
mV P - P
±0.03
%/ºC
Max.
Units
Ripple & Noise (20 MHz)
See Note 3
Output Power Protection
%
120
%
Temperature Coefficient
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Min.
60 Seconds
1,500
500 VDC
1,000
Typ.
VDC
M⍀
Isolation Capacitance
100
pF
Switching Frequency
300
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Min.
Ambient
Storage Temperature Range
Cooling
Max.
Units
-40
Typ.
+85
ºC
-55
+125
ºC
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size (See Note 4)
1.25 x 0.80 x 0.37 Inches (31.8 x 20.3 x 9.5 mm)
Case Material (See Note 4)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Non-Conductive Black Plastic (UL94V-0)
Weight
0.52 Oz (15g)
Reliability Specifications
Parameter
Conditions
MTBF
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
1.0
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
-0.7
40.0
48 VDC Input
-0.7
80.0
1.5 mm From Case For 10 Sec
Internal Power Dissipation
Max.
24 VDC Input
All Models
VDC
300
ºC
2,500
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
www.micropowerdirect.com
Model Selection Guide
Model
Number
Voltage (VDC)
Nominal
Range
24
24
24
24
24
24
24
48
48
48
48
48
48
48
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
Input
Current (mA)
Output
Fuse Rating
Reflected
Efficiency
Slow-Blow
Current
Ripple Voltage Current
(%, Typ)
(mA)
(VDC) (mA, Max) (mA, Min)
Full-Load No-Load Current
(mA, Typ)
A301ERU
A302ERU
A303ERU
A304ERU
A305ERU
A306ERU
A307ERU
A311ERU
A312ERU
A313ERU
A314ERU
A315ERU
A316ERU
A317ERU
169
164
157
157
164
157
157
84
80
78
78
82
78
78
16
16
16
16
16
16
16
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
909
600
250
200
±300
±125
±100
909
600
250
200
±300
±125
±100
90.0
60.0
25.0
20.0
±30.0
±12.0
±10.0
90.0
60.0
25.0
20.0
±30.0
±12.0
±10.0
74
76
80
80
76
80
80
74
78
80
80
76
80
80
750
750
750
750
750
750
750
500
500
500
500
500
500
500
Derating Curve
For models with a metal case, add an
“M” to the model number (ie: A315ERUM)
Notes:
1. Exceeding the input range by a significant margin may damage the units. For 24V input the input voltage
should not exceed 40V; for 48V models it should not exceed 80V.
2. Voltage accuracy for the negative output on Dual output models is typically ±3% with a max of ±5%.
3. Maximum ouput noise for dual output units is 150 mV P-P. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single
output units and from each output to common for dual output units.
4. The optional metal package is nickel plated steel. The dimensions of the metal package are 1.25 x 0.80 x 0.39
Inches (31.8 x 20.3 x 10.0 mm).
5. These units should not be operated with a load under the specified minimum. Operation at no-load will
increase ripple significantly and may cause damage to the unit.
6. These converters are specified for operation without external components. However, in some applications
the addition of input/output capacitors will enhance stability and reduce output ripple. Recommended
capacitor values are:
Vin: 10 µF - 47 µF
Vout: 10 µF/100 mA
For applications requiring very low output noise levels, a simple LC filter
should be effective.
7. The maximum load capacitance is:
Mechanical Dimensions
Vout
Maximum
Load
Capacitance
3.3 VDC
5 VDC
12 VDC
15 VDC
2,200 µF
1,000 µF
470 µF
330 µF
Vout
Maximum
Load
Capacitance
±5 VDC
±12 VDC
±15 VDC
2,200 µF
1,000 µF
470 µF
8. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections
Pin
Single
Dual
2, 3
-Vin
-Vin
9
NC
Common
10
NC
NC
11
NC
-Vout
14
+Vout
+Vout
15
NC
NC
16
-Vout
Common
22, 23
+Vin
+Vin
NC: No Connection
Mechanical Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]