A100ERU Series Single & Dual Output, 1.5W Ultra-Wide Input Range DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Key Features: • 1.5W Output Power • 4:1 Input Voltage Range • 1,500 VDC Isolation • -40ºC to +85ºC Temp Range • Compact DIP Case • Single & Dual Outputs • 1.0 MH MTBF • Industry Standard Pin-Out • Low, Low Cost! Parameter Conditions Input Voltage Range (See Note 1) Min. Typ. Max. 24 VDC Input 9.0 24.0 36.0 48 VDC Input 18.0 48.0 72.0 Input Filter Units VDC Capacitors Short Circuit Input Power 1,000 mW Output Parameter Conditions Min. Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Typ. Max. Units ±1.0 ±3.0 % % Dual Output , Balanced Loads ±3.0 Vin = Min to Max ±0.2 ±0.75 Iout = 10% to 100% ±0.5 ±2.0 % 50 100 mV P - P 50 mV P - P ±0.03 %/ºC Max. Units Noise (20 Hz - 300 kHz) See Note 2 Ripple (DC - 20 MHz) Output Power Protection % 120 % Temperature Coefficient Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Isolation Voltage Isolation Resistance Min. 60 Seconds 1,500 500 VDC 1,000 Isolation Capacitance Typ. VDC M⍀ 100 Switching Frequency pF 550 kHz Environmental Parameter Conditions Operating Temperature Range Min. Ambient Storage Temperature Range Cooling Max. Units -40 Typ. +85 ºC -50 +125 ºC Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Size (See Note 3) MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com 1.25 x 0.80 x 0.37 Inches (31.8 x 20.3 x 9.5 mm) Case Material (See Note 3) Non-Conductive Black Plastic (UL94V-0) Weight 0.52 Oz (15g) Reliability Specifications Parameter Conditions MTBF Min. MIL HDBK 217F, 25ºC, Gnd Benign Typ. Max. 1.0 Units MHours Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature Min. Typ. -0.7 50.0 48 VDC Input -0.7 100.0 1.5 mm From Case For 10 Sec Internal Power Dissipation Max. 24 VDC Input All Models VDC 300 ºC 1,500 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Units www.micropowerdirect.com Model Selection Guide Input Model Number A101ERU A102ERU A103ERU A104ERU A105ERU A106ERU A107ERU A108ERU A111ERU A112ERU A113ERU A114ERU A115ERU A116ERU A117ERU A118ERU Voltage (VDC) Output Current (mA) Voltage Current Current Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) 24 9.0 - 36.0 86 20 3.3 500 50.0 24 9.0 - 36.0 83 20 5.0 300 30.0 24 9.0 - 36.0 80 20 9.0 167 17.0 24 9.0 - 36.0 78 20 12.0 125 12.0 24 9.0 - 36.0 77 20 15.0 100 10.0 24 9.0 - 36.0 85 20 ±5.0 ±150 ±15.0 24 9.0 - 36.0 80 20 ±12.0 ±63 ±6.0 24 9.0 - 36.0 79 20 ±15.0 ±50 ±5.0 48 18.0 - 72.0 43 10 3.3 500 50.0 48 18.0 - 72.0 42 10 5.0 300 30.0 48 18.0 - 72.0 40 10 5.0 167 17.0 48 18.0 - 72.0 39 10 12.0 125 12.0 48 18.0 - 72.0 39 10 15.0 100 10.0 48 18.0 - 72.0 43 10 ±5.0 ±150 ±15.0 48 18.0 - 72.0 40 10 ±12.0 ±63 ±6.0 48 18.0 - 72.0 40 10 ±15.0 ±50 ±5.0 Efficiency (%, Typ) Fuse Rating Slow-Blow (mA) 73 75 78 80 81 73 78 79 72 74 77 79 80 72 77 78 200 200 200 200 200 200 200 200 150 150 150 150 150 150 150 150 Derating Curve For models with a metal case, add an “M” to the model number (ie: A115ERUM) Notes: 1. Exceeding the input range by a significant margin may damage the units. For 24V input the input voltage should not exceed 40V; for 48V models it should not exceed 80V. 2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 3. The optional metal package is nickel plated steel. Dimensions are 1.25 x 0.80 x 0.39 Inches (31.8 x 20.3 x 10.0 mm). 4. These units should not be operated with a load under the specified minimum. Operation at no-load will increase ripple significantly and may cause damage to the unit. 5. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors will enhance stability and reduce output ripple. Recommended capacitor values are: Vin (VDC) 24 48 Input Capacitor Vout (VDC) Sing 10 µF Dual 10 ~ 47 µF Sing 10 µF Dual 10 ~ 47 µF 3.3 5 12 15 Output Capacitor 0 to +70ºC -40 to +85ºC (Electrolytic) (Tantalum) 100 µF 100 µF 100 µF 100 µF 47 µF 47 µF 47 µF 47 µF Mechanical Dimensions For applications requiring very low output noise levels, a simple LC filter should be effective. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Pin Connections Pin Single 2, 3 -Vin -Vin 9 No Pin Common 10 NC NC 11 NC -Vout 14 +Vout +Vout 15 NC NC 16 -Vout Common +Vin +Vin 22, 23 Dual NC: No Connection Mechanical Notes: MicroPower Direct • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]