F3000TERU Datasheet

F3000TERU
Series
Compact, 4:1 Input
30W, Triple Output
DC/DC Converters
Electrical Specifications
Key Features:
• 30W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• Triple Outputs
• Compact 1.6 x 2 In. Case
• -40ºC to +85ºC Operation
• >1.0 MHour MTBF
• Remote ON/OFF
• Industry Standard Pin-Out
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Under Voltage Shutdown
Input Filter, See Note 1
Input Reflected Ripple Current
Start Up Time
Typ.
24.0
48.0
Max.
36.0
75.0
9.0
17.8
30
10
Units
VDC
VDC
mA
mS
Output
Parameter
Conditions
Output Voltage Accuracy
Single & Dual
Output Models
Available
F3000ERU Series
Conditions
Min.
24 VDC Input
9.0
48 VDC Input 18.0
24 VDC Input
8.0
48 VDC Input 16.0
␲ (Pi) Filter
Line Regulation, For VIN Min to Max
Load Regulation, IOUT = 10% to 100%
Ripple & Noise, See Note 2
Output Power Protection
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Min.
Main Output
Auxiliary Outputs
Main Output
Auxiliary Outputs
Main Output
Auxiliary Outputs
Typ.
±1.0
±3.0
85
130
300
25% Load Step Change
±3.0
±0.03
Continuous (Autorecovery)
Max.
±3.0
±5.0
±1.0
±5.0
±2.0
±5.0
120
110
500
±5.0
Units
%
%
%
mV P - P
%
µSec
%
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off (Note 4)
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Conditions
60 Seconds
500 VDC
100 kHz, 0.1V
Conditions
Min.
1,500
1,000
Typ.
Max.
2,000
400
Min.
3.5
-0.0
Typ.
Min.
-40
Typ.
Units
VDC
M⍀
pF
kHz
Max.
Units
12.0
VDC
1.2
VDC
1
mA
Referenced to Negative Input (pin 2)
Environmental
Parameter
Conditions
Operating Temperature Range
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Ambient
Case
-55
Free Air Convection
RH, Non-condensing
Max.
+85
+105
+125
Units
°C
°C
°C
95
%
2.0 x 1.6 x 0.42 Inches (50.8 x 40.6 x 11.8 mm)
Metal with Non-Conductive Base
1.76 Oz (50g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1,000
Typ.
Max.
Units
kHours
Min.
-0.7
-0.7
Typ.
Max.
40.0
80.0
300
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Model
Number
F3001TERU
F3002TERU
F3003TERU
F3004TERU
F3011TERU
F3012TERU
F3013TERU
F3014TERU
Voltage (VDC)
Nom. Range
24
9 - 36
24
9 - 36
24
9 - 36
24
9 - 36
48 18 - 75
48 18 - 75
48 18 - 75
48 18 - 75
Input
Output 1
Current (mA)
Voltage Current Current
Full-Load No-Load (VDC) (A, Max) (A, Min)
1,450
30
3.3
3.500
0.175
1,450
30
3.3
3.500
0.175
1,420
30
5.0
3.000
0.150
1,420
30
5.0
3.000
0.150
720
30
3.3
3.500
0.175
720
30
3.3
3.500
0.175
712
30
5.0
3.000
0.150
712
30
5.0
3.000
0.150
Outputs 2/3
OVP
(VDC)
3.90
3.90
6.20
6.20
3.90
3.90
6.20
6.20
Voltage Current Current
OVP
(VDC)
(A, Max)
(A, Min)
(VDC)
±12.0
±15.0
±12.0
±15.0
±12.0
±15.0
±12.0
±15.0
±0.625
±0.500
±0.625
±0.500
±0.625
±0.500
±0.625
±0.500
±0.031
±0.025
±0.031
±0.025
±0.031
±0.025
±0.031
±0.025
±15.0
±18.0
±15.0
±18.0
±15.0
±18.0
±15.0
±18.0
Efficiency
(Typ %)
Fuse
Rating
Slow-Blow
(mA)
85
86
88
88
85
85
88
87
2,500
2,500
2,500
2,500
2,000
2,000
2,000
2,000
Derating Curves
For Heatsink Option, add suffix “H” to model number
(i.e. F3003ERU-H)
Notes:
1. With the addition of a simple external circuit, the units will pass
VOUT
Output Cap.
EN 55022 and EN 61000 EMI specifications. Contact the factory
3.3 VDC
10 µF
for recommendations.
5 VDC
10 µF
2. When measuring output ripple, it is recommended that an
±4.7 µF
external ceramic capacitor (see table at right) be placed from ±12 VDC
±4.7 µF
the +Vout pin to the -Vout pin for single output units and from ±15 VDC
each output to common for dual output units.
3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
4. The Remote On/Off Control input (Pin 4) is referenced to -Vin (Pin 2). This input may be tied directly
to ground, but it is recommended that connection to the pin should be made through a 1k⍀ resistor
and diode (1N4148). If it is not used, the control pin should be left open.
5. Operation at no-load will not damage these units. However, they may not meet all specifications.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above
for the correct rating.
Mechanical Dimensions
Heatsink Dimensions (Optional)
Pin
Connections
MicroPower Direct
Pin
Function
1
+VIN
2
-VIN
4
ON/OFF
5
+VOUT2
6
+VOUT1
7
-VOUT1
8
-VOUT2
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]