MPM-15S Series Universal Input, 15W Miniature, PC Mount AC/DC Power Supplies Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input • 15W Output Power Parameter • Universal 85-264 VAC Input Input Voltage Range • EN 60950 Approved (UL) Input Frequency Input Current • Meets IEC Safety Class II • Adjustable Output Min. Typ. 85 120 47 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Max. 264 370 63 Conditions Min. Typ. See Model Selection Guide See Model Selection Guide ±2.0 ±0.5 VIN = Min to Max See Note 2 ±1.0 50 115 VAC 30 230 VAC 80 ±0.02 Continuous (Autorecovery) Zener Diode Clamp Autorecovery 110 Max. Units 100 % % % mV P-P Conditions Input to Output 500 VDC Max. Inrush Current • Meets EN 55022 B Output • >300 kHour MTBF Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) • Compact PC Mount Case Conditions Hold-Up Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection Units VAC VDC Hz A Pk mSec %/°C %W General Parameter Isolation Voltage Isolation Resistance Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge Min. 3,000 100 Typ. 65 Standard See Note 4 See Note 5 EN 55022 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 Min. Typ. Min. -40 Typ. +25 Units VAC M kHz Max. Units Class B Class B Criteria B; ±8 kV Air/±6 kV Contact Criteria A; 10V/m Criteria B; ±2 kV Criteria B; ±1 kV/±2 kV Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Max. +70 +90 -40 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Case Units °C °C °C % Physical T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Case Size Case Material Weight 2.44 x 1.77 x 0.88 Inches (62.0 x 45.0 x 22.50 mm) Non-Conductive Black Plastic (UL94-V0) 2.82 Oz (80g) Reliability Specifications Parameter MTBF Safety Standards Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 300 EN 60950 IEC 60536 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Model Number MPM-15S-03 MPM-15S-05 MPM-15S-09 MPM-15S-12 MPM-15S-15 MPM-15S-24 MPM-15S-48 Input Output Current (A) Current (A) Voltage Max Min 115 VAC 230 VAC (VDC) 0.25 0.14 3.3 3.00 0.0 0.25 0.14 5.0 2.80 0.0 0.25 0.14 9.0 1.60 0.0 0.25 0.14 12.0 1.25 0.0 0.25 0.14 15.0 1.00 0.0 0.25 0.14 24.0 0.62 0.0 0.25 0.14 48.0 0.32 0.0 Typical Connection Notes: Over Volt. ciency 1. Operation at no load will not damage the units, however, they may not meet Protection Effi all specifications. (%, Typ) (VDC) 7.5 7.5 12.0 20.0 20.0 30.0 60.0 2. Load regulation is measured for an output change of 10% to 100% at nominal input line. 3. All units are rated for EN 55022 (CE/RE) class B without external components. 4. All units are rated for EN 61000-4-4 (±2 kV) without external components. They will meet EN 61000-4-4 (±4 kV) with additional input filtering as shown below. 5. All units are rated for EN 61000-4-5 (±1 kV/±2 kV) without external components. They will meet EN 61000-4-5 (±2 kV/±4 kV) with additional input filtering as shown below. 6. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-15S series, a 2.0A/250 VAC slow blow should be used. 73 76 78 80 80 84 85 The diagram below illustrates a typical application connection of the MPM-15S-xx series. Notes on this circuit (starting with the input circuit) are: 1. It is recommended that an external fuse and NTC be used. The recommended fuse is a 3.15A/250V slow blow and for the NTC, a 5D-9. 2. An external MOV is required on the input to protect the unit in the event of a surge. A 561KD14 or equivalent is recommended. 3. Recommended output filtering capacitors are: C1 680 µF/16V 680 µF/16V 470 µF/25V 220 µF/25V 220 µF/25V 68 µF/25V 33 µF/25V MPM-15S-03 MPM-15S-05 MPM-15S-09 MPM-15S-12 MPM-15S-15 MPM-15S-24 MPM-15S-48 Typical Connection: With ACFM-01 Input Module (See note 4) C2 0.01 µF/25V 0.01 µF/25V 0.01 µF/25V 0.01 µF/25V 0.01 µF/25V 0.01 µF/25V 0.01 µF/25V TVS SMBJ7.0A SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A SMBJ60A Output capacitor (C2) is a high frequency, low resistance electrolytic capacitor. Capacitor (C1) is ceramic. Voltage derating of capacitors should be >80%. 4. Input noise and surge suppression modules are available for a number of MPD AC/DC power supplies.An MPM-15S-xx connection with the ACFM-01 is illustrated in the diagram at left. For pricing or full technical information on these modules (ACFM-01 and ACFM-02) please contact the factory. Pin Connections Pin Function 2 AC-Neutral 3 AC-Line Derating Curve Pin 4 8 Function -Vout +Vout Mechanical Dimensions Input Voltage Vs Load Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct The MPM-15-xx series is also available with a chassis mount or DIN mount adapter. Contact the factory for more information We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]