MPD MPS-03

MPS-03 Series
Single Output, 3W
Ultra-Miniature SIP
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 3W Output Power
• Universal 85-264 VAC Input
• 100 - 400 VDC Input
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
• Meets IEC Safety Class II
Input Frequency
• -40ºC to +85ºC Operation
Input Current
• Single Regulated Output
Inrush Current, See Note 1
• >300 kHour MTBF
• Ultra-Miniature SIP Case
Min.
See Note 1
Typ.
Max.
Units
85
264
VAC
100
400
VDC
47
63
Hz
See Model Selection Guide
115 VAC
10
230 VAC
20
Leakage Current
A
50
µA
Max.
Units
Output
Parameter
Conditions
Min.
Typ.
Output Voltage
See Model Selection Guide
Output Current
See Model Selection Guide
Output Voltage Accuracy
Line Regulation
±2.0
%
VIN = 10% to 100%
±0.5
%
See Note 2
±1.0
%
Load Regulation
Ripple & Noise (20 MHz)
3.3V And 5V Output Models
50
All Other Models
100
Hold Time, See Note 1
115 VAC
16
230 VAC
40
Temperature Coefficient
mV Pk - Pk
mS
±0.02
Short Circuit Protection
%/°C
Continuous (Autorecovery)
Over Temperature Protection
See Note 3
150
°C
Max.
Units
General
Parameter
Conditions
Isolation Voltage
Min.
Input to Output, 60 Sec
Typ.
2,000
Switching Frequency
VAC
100
kHz
Environmental
Parameter
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Operating Temperature Range
Ambient
Operating Temperature Range
Case
Storage Temperature Range
Cooling
Min.
Typ.
Max.
Units
-40
+25
+85
°C
+90
°C
+105
°C
-40
Free Air Convection (See Derating Curve)
Humidity
RH, Non-condensing
85
%
Physical
Case Size
1.38 x 0.42 x 0.87 Inches (35.0 x 10.6 x 22.5 mm)
Case Material
Non-Conductive Epoxy (UL94-V0)
Weight
1.24 Oz (35g)
Reliability Specifications
Parameter
MTBF
Safety Class
Conditions
Min.
MIL HDBK 217F, 25°C, Gnd Benign
Typ.
300
IEC 61140 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Typical Connection
Output
Model
Number
Current
Voltage
Current
(mA)
(VDC)
(mA)
MPS-03S-03
MPS-03S-05
MPS-03S-09
MPS-03S-12
MPS-03S-15
MPS-03S-24
40
40
40
40
40
40
3.3
5.0
9.0
12.0
15.0
24.0
500
500
330
250
200
125
Efficiency
(%, Typ)
70
70
75
78
78
78
Notes:
1. Specified with a C4 (see typical connection diagram at right) value of
22 uF/400V. A high frequency, low impedance electrolytic capacitor should
be used. For use with an AC input, C4 must be installed.
2. Load regulation is measured for an output change of 10% to 100% at nominal
input line.
3. The unit will shut down when the over temperature protection is triggered. The
unit will restart when the ambient operating temperature falls below 85ºC.
4. It is recommended that a fuse be used on the input of a power supply for
protection. For the MPS-03 series, a 0.5A/250 VAC slow blow should be
used.
The diagram above illustrates a typical application connection of the MPS-03 series. The
top diagram illustrates a DC/DC converter connection while the bottom diagram show the
unit connected as an AC/DC power supply. Notes on these circuits are:
Derating Curve
1. To maintain clearance and creepage distances (for Class I & Class II devices) the board
layout should guarantee the following spacing between the L and N inputs (before the
fuse):
Clearance - 2 mm
Creepage - 2.5 mm
2. The recommended fuse is a 0.5A/250V slow blow.
3. For EMI sensitive applications, the input filtering circuit (inside the dotted boxes of the
AC circuit) may be added. The filter consists of:
Cx: Capacitor C1 is 0.1 µF/275V
CY: Capacitors C2 and C3 are 220 pF/2000V
T1: Common mode choke, UU9.8 or ring core. Inductance is
about 10 mH to 30 mH & wire diameter of 0.22 mm.
4. The MOV is required for surge protection.
Recommended is a 471KD07.
5. The input storage capacitor (C4) is a low ESR
electrolytic with a rating of 22 µF /400V. This
capacitor must be used for operation with an
AC input.
6. The output filtering capacitor (C5) is a high
frequency, low resistance electrolytic capacitor.
A ceramic capacitor (C6) is used to filter high
frequency noise. Recommended values are
given in the table at right.
Mechanical Dimensions
VOUT
3.3
5.0
9.0
12.0
15.0
24.0
C5
(µF/V)
150/25
150/25
150/25
150/25
100/35
100/35
C6
(µF/V)
0.1/50
0.1/50
0.1/50
0.1/50
0.1/50
0.1/50
TVS
P4KE6.8A
P4KE6.8A
P4KE12A
P4KE20A
P4KE20A
P4KE33A
7. The TVS is recommended to protect application circuitry in the event of a fault. Recommended values are given in the table above.
Pin Connections
Pin
Function
1
3
7
10
12
+Vin (AC-Line)
CAP
-Vin (AC-Neutral)
-Vout
+Vout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]