MPD MPM-05PB

MPM-05PB Series
Very Low Cost, 5W
Compact “Power Brick”
AC/DC Power Supplies
Key Features:
Electrical Specifications
• 5W Output Power
• Compact 1 x 2 Inch Case
• Universal 85-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Industry Standard Pin-Out
• Meets EN 55022
• >200 kHour MTBF
• Low, Low Cost
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
Typ.
85
110
47
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
Meets CISPR Pub. 22/FCC Class A
Input Voltage Range
Input Frequency
Input Current
Inrush Current
EMI
Max.
264
370
440
Units
VAC
VDC
Hz
A Pk
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over temperature Protection
Over Voltage Protection, See Note 3
Short Circuit Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Note 1
±2.0
VIN = Min to Max
±0.5
See Note 2
±1.0
30
230 VAC, 60 Hz
50
±0.02
Max.
Units
150
%
%
%
mV P-P
mSec
%/°C
°C
See Model Selection Guide
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Isolation Resistance
EMI/RFI
EMC Compliance
Conditions
Input to Output, Flash Tested For 60S
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Min.
4,000
100
Typ.
Conditions
Min.
-25
Typ.
+25
Switching Frequency
Max.
Units
VAC
M
EN 55022 Level A
EN 61000-4-2 Level 4 8kV/15 kV
EN 61000-4-3
EN 61000-4-4 Level 4 4 kV
EN 61000-4-5 Level 4 2kV/2 kV
100
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Max.
+70
+95
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Case
Units
°C
°C
°C
%
Physical
Case Size
Case Material
Weight
2.00 x 1.00 x 0.60 Inches (50.8 x 25.4 x 15.16 mm)
Non-Conductive Black Plastic (UL94-V0)
1.22 Oz (35g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
200
UL 60950, EN 60950
UL, cUL; File No. E245422
IEC 61140 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output
Current (A)
Over Voltage
Protection
Efficiency
115 VAC
230 VAC
(VDC)
MPM-05S-03PB
0.110
0.070
3.3
Current (A)
Peak
Max.
(60 Sec)
1.250
1.400
MPM-05S-05PB
0.110
0.070
5.0
1.000
1.300
ⱕ6.5
72
MPM-05S-09PB
0.110
0.070
9.0
0.550
0.700
ⱕ12.0
74
MPM-05S-12PB
0.110
0.070
12.0
0.420
0.550
ⱕ20.0
76
MPM-05S-15PB
0.110
0.070
15.0
0.333
0.450
ⱕ20.0
76
MPM-05S-24PB
0.110
0.070
24.0
0.230
0.300
ⱕ30.0
78
Typical Connection
Voltage
(VDC)
ⱕ6.5
(%, Typ)
66
Notes:
1. For the 3.3V output model, Output Accuracy is
±3.0%
2. Load regulation is measured for an output
change of 10% to 100% at nominal input line.
3. Over voltage protection is provided by a diode
clamp & chip lock up.
4. It is recommended that a fuse be used on the
input of a power supply for protection. For the
MPM-05PB series, a 1A/250 VAC slow blow
should be used.
The diagram below illustrates a typical application connection of the MPM-05PB series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse, NTC and MOV be added to the input
to the unit. For the fuse, a 1A/250V slow blow is recommended. For the NTC, a
5D-9 may be used. added to the input. To protect the unit in the event of a surge.
A 471KD05 or equivalent MOV is recommended.
2. For EMI sensitive applications, the input filtering circuit (inside the dotted boxes)
may be added. The filter consists of a common mode choke and x/y caps:
C1
0.1 µF/275V
C2/C3
220 pF/400V
T1
10 - 30 mH
3. Recommended output filtering capacitors are:
MPM-05S-03PB
MPM-05S-05PB
MPM-05S-09PB
MPM-05S-12PB
MPM-05S-15PB
MPM-05S-24PB
Derating Curve
C4
47 µF/10V
47 µF/10V
33 µF/25V
33 µF/25V
33 µF/25V
10 µF/35V
C5
0.1 µF/50V
0.1 µF/50V
0.1 µF/50V
0.1 µF/50V
0.1 µF/50V
0.1 µF/50V
TVS
P6KE6.8A
P6KE6.8A
P6KE12A
P6KE20A
P6KE20A
P6KE30A
The output filtering capacitor (C4) is a high frequency, low resistance electrolytic
capacitor. Capacitor (C5) is ceramic. Voltage derating of capacitors should be 80%
or above. The TVS is added to protect circuitry being powered.
Pin Connections
Pin
Function
Pin
Function
1
2
AC-Neutral
AC-Line
3
4
+Vo
-Vo
Mechanical Dimensions
Input Voltage Vs Load
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]