MPM-05PB Series Very Low Cost, 5W Compact “Power Brick” AC/DC Power Supplies Key Features: Electrical Specifications • 5W Output Power • Compact 1 x 2 Inch Case • Universal 85-264 VAC Input • EN 60950 Approved (UL) • Meets IEC Safety Class II • Industry Standard Pin-Out • Meets EN 55022 • >200 kHour MTBF • Low, Low Cost Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Min. Typ. 85 110 47 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Meets CISPR Pub. 22/FCC Class A Input Voltage Range Input Frequency Input Current Inrush Current EMI Max. 264 370 440 Units VAC VDC Hz A Pk Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over temperature Protection Over Voltage Protection, See Note 3 Short Circuit Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Note 1 ±2.0 VIN = Min to Max ±0.5 See Note 2 ±1.0 30 230 VAC, 60 Hz 50 ±0.02 Max. Units 150 % % % mV P-P mSec %/°C °C See Model Selection Guide Continuous (Autorecovery) General Parameter Isolation Voltage Isolation Resistance EMI/RFI EMC Compliance Conditions Input to Output, Flash Tested For 60S 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 4,000 100 Typ. Conditions Min. -25 Typ. +25 Switching Frequency Max. Units VAC M EN 55022 Level A EN 61000-4-2 Level 4 8kV/15 kV EN 61000-4-3 EN 61000-4-4 Level 4 4 kV EN 61000-4-5 Level 4 2kV/2 kV 100 kHz Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Max. +70 +95 -40 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Case Units °C °C °C % Physical Case Size Case Material Weight 2.00 x 1.00 x 0.60 Inches (50.8 x 25.4 x 15.16 mm) Non-Conductive Black Plastic (UL94-V0) 1.22 Oz (35g) Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 200 UL 60950, EN 60950 UL, cUL; File No. E245422 IEC 61140 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number Output Current (A) Over Voltage Protection Efficiency 115 VAC 230 VAC (VDC) MPM-05S-03PB 0.110 0.070 3.3 Current (A) Peak Max. (60 Sec) 1.250 1.400 MPM-05S-05PB 0.110 0.070 5.0 1.000 1.300 ⱕ6.5 72 MPM-05S-09PB 0.110 0.070 9.0 0.550 0.700 ⱕ12.0 74 MPM-05S-12PB 0.110 0.070 12.0 0.420 0.550 ⱕ20.0 76 MPM-05S-15PB 0.110 0.070 15.0 0.333 0.450 ⱕ20.0 76 MPM-05S-24PB 0.110 0.070 24.0 0.230 0.300 ⱕ30.0 78 Typical Connection Voltage (VDC) ⱕ6.5 (%, Typ) 66 Notes: 1. For the 3.3V output model, Output Accuracy is ±3.0% 2. Load regulation is measured for an output change of 10% to 100% at nominal input line. 3. Over voltage protection is provided by a diode clamp & chip lock up. 4. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-05PB series, a 1A/250 VAC slow blow should be used. The diagram below illustrates a typical application connection of the MPM-05PB series. Notes on this circuit (starting with the input circuit) are: 1. It is recommended that an external fuse, NTC and MOV be added to the input to the unit. For the fuse, a 1A/250V slow blow is recommended. For the NTC, a 5D-9 may be used. added to the input. To protect the unit in the event of a surge. A 471KD05 or equivalent MOV is recommended. 2. For EMI sensitive applications, the input filtering circuit (inside the dotted boxes) may be added. The filter consists of a common mode choke and x/y caps: C1 0.1 µF/275V C2/C3 220 pF/400V T1 10 - 30 mH 3. Recommended output filtering capacitors are: MPM-05S-03PB MPM-05S-05PB MPM-05S-09PB MPM-05S-12PB MPM-05S-15PB MPM-05S-24PB Derating Curve C4 47 µF/10V 47 µF/10V 33 µF/25V 33 µF/25V 33 µF/25V 10 µF/35V C5 0.1 µF/50V 0.1 µF/50V 0.1 µF/50V 0.1 µF/50V 0.1 µF/50V 0.1 µF/50V TVS P6KE6.8A P6KE6.8A P6KE12A P6KE20A P6KE20A P6KE30A The output filtering capacitor (C4) is a high frequency, low resistance electrolytic capacitor. Capacitor (C5) is ceramic. Voltage derating of capacitors should be 80% or above. The TVS is added to protect circuitry being powered. Pin Connections Pin Function Pin Function 1 2 AC-Neutral AC-Line 3 4 +Vo -Vo Mechanical Dimensions Input Voltage Vs Load Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]