MPM-05S Series Universal Input, 5W Miniature PC Mount AC/DC Power Supplies Electrical Specifications Key Features: Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input • 5W Output Power Parameter • Universal 85-264 VAC Input Input Voltage Range • EN 60950 Approved (UL) • Six Single Output Models • Meets EN 55022 B • >300 kHour MTBF • Compact PC Mount Case Conditions Input Frequency Input Current Inrush Current EMI Safety Ground Leakage Current Min. Typ. 85 120 47 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Meets CISPR Pub. 22/FCC Class B 230 VAC 0.3 Max. 264 370 63 Units VAC VDC Hz A Pk mA Output The MPM-05S series is also available with a chassis mount or DIN mount adapter. Please contact the factory for more information Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Short Circuit Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide ±2.0 ±0.5 See Note 2 ±1.0 50 115 VAC 15 230 VAC 80 ±0.02 Continuous (Autorecovery) Autorecovery 110 Max. Units 150 % % % mV Pk - Pk Conditions Input to Output Max. mSec %/°C %W General Parameter Isolation Voltage Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge Min. 3,000 Typ. 140 Conditions See Note 3 EN 55022 See Note 3 EN 55022 EN 61000-4-2 EN 61000-4-3 See Note 4 EN 61000-4-4 See Note 4 EN 61000-4-5 Min. Units VAC kHz Typ. Max. Units Class B Class B Criteria B; ±8 kV Air/±6 kV Contact Criteria A; 10V/m Criteria B; ±2 kV Criteria B; ±1 kV/ ±2 kV Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Min. Typ. Max. -25 +25 +70 -25 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % See Mechanical Diagram On Page 2 Non-Conductive Black Plastic (UL94-V0) 1.76 Oz (50g) Reliability Specifications Parameter MTBF Safety Standards Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 300 UL 60950, EN 60950 www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number MPM-05S-03 MPM-05S-05 MPM-05S-09 MPM-05S-12 MPM-05S-15 MPM-05S-24 Current (A) 115 VAC 0.120 0.120 0.120 0.120 0.120 0.120 230 VAC 0.070 0.070 0.070 0.070 0.070 0.070 Typical Connection Output Voltage Over Volt. Current Protection (VDC) (A Max.) (VDC) 3.3 5.0 9.0 12.0 15.0 24.0 1.250 1.000 0.550 0.420 0.330 0.230 7.5 7.5 12.0 20.0 20.0 30.0 Efficiency (%, Typ) 70 75 77 79 80 82 Notes: 1. Operation at no load will not damage the units, however, they may not meet all specifications. 2. Load regulation is measured for an output change of 10% to 100% at nominal input line. 3. All units are rated for EN 55022 (CE/RE) class B without external components. 4. All units are rated for EN 61000-4-4 (±2 kV) and EN 61000-4-5 (±1 kV/±2 kV) without external components. They will meet EN 61000-4-4 (±4 kV), and EN 61000-4-5 (±2 kV/±4 kV) with additional input filtering as shown below. 5. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-05S-xx series, a 1.0A/250 VAC slow blow should be used. The diagram below illustrates a typical application connection of the MPM-05S series. Notes on this circuit (starting with the input circuit) are: 1. It is recommended that an external fuse and NTC be used. The recommended fuse is a 1.0A/250V slow blow and for the NTC, a 5D-9. 2. An external MOV is required on the input to protect the unit in the event of a surge. A S14K350 or equivalent is recommended. 3. Recommended output filtering capacitors are: C1 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V 1.0 µF/50V MPM-05S-03 MPM-05S-05 MPM-05S-09 MPM-05S-12 MPM-05S-15 MPM-05S-24 Typical Connection: With MACFM-02A Input Module (See note 4) C2 330 µF/10V 330 µF/10V 120 µF/10V 120 µF/25V 68 µF/25V 68 µF/35V TVS SMBJ7.0A SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A The output filtering capacitor (C2) is a high frequency, low resistance electrolytic capacitor. Capacitor (C1) is ceramic. Voltage derating of capacitors should be 80% or above. 4. Input noise and surge suppression modules are available for a number of MPD AC/DC power supplies. An MPM-05S-xx connection with the MACFM-02A is illustrated in the diagram at left. For pricing or full technical information on these modules, please contact the factory. Pin Connections Pin Function Pin Function 1 2 AC-Ground AC-Neutral 3 4 8 AC-Line -Vout +Vout Mechanical Dimensions Derating Curve Input Voltage Vs Load MicroPower Direct Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]