Electrical Specifications
Key Features:
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 5W Output Power
Parameter
• Universal 85-264 VAC Input
Input Voltage Range
• EN 60950 Approved (UL)
• Six Single Output Models
• Meets EN 55022 B
• >300 kHour MTBF
• Compact PC Mount Case
Conditions
Input Frequency
Input Current
Inrush Current
EMI
Safety Ground Leakage Current
Min.
Typ.
85
120
47
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
Meets CISPR Pub. 22/FCC Class B
230 VAC
0.3
Max.
264
370
63
Units
VAC
VDC
Hz
A Pk
mA
Output
The MPM-05S series is
also available with a chassis
mount or DIN mount adapter.
Please contact the factory
for more information
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overload Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
±2.0
±0.5
See Note 2
±1.0
50
115 VAC
15
230 VAC
80
±0.02
Continuous (Autorecovery)
Autorecovery
110
Max.
Units
150
%
%
%
mV Pk - Pk
Conditions
Input to Output
Max.
mSec
%/°C
%W
General
Parameter
Isolation Voltage
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
Min.
3,000
Typ.
140
Conditions
See Note 3
EN 55022
See Note 3
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 4
EN 61000-4-4
See Note 4
EN 61000-4-5
Min.
Units
VAC
kHz
Typ.
Max.
Units
Class B
Class B
Criteria B; ±8 kV Air/±6 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±1 kV/ ±2 kV
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
Max.
-25
+25
+70
-25
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
See Mechanical Diagram On Page 2
Non-Conductive Black Plastic (UL94-V0)
1.76 Oz (50g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
300
UL 60950, EN 60950
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MPM-05S-03
MPM-05S-05
MPM-05S-09
MPM-05S-12
MPM-05S-15
MPM-05S-24
Current (A)
115 VAC
0.120
0.120
0.120
0.120
0.120
0.120
230 VAC
0.070
0.070
0.070
0.070
0.070
0.070
Typical Connection
Output
Voltage
Over Volt.
Current Protection
(VDC)
(A Max.)
(VDC)
3.3
5.0
9.0
12.0
15.0
24.0
1.250
1.000
0.550
0.420
0.330
0.230
7.5
7.5
12.0
20.0
20.0
30.0
Efficiency
(%, Typ)
70
75
77
79
80
82
Notes:
1. Operation at no load will not damage the units, however, they may not meet
all specifications.
2. Load regulation is measured for an output change of 10% to 100% at nominal
input line.
3. All units are rated for EN 55022 (CE/RE) class B without external components.
4. All units are rated for EN 61000-4-4 (±2 kV) and EN 61000-4-5 (±1 kV/±2 kV)
without external components. They will meet EN 61000-4-4 (±4 kV), and EN
61000-4-5 (±2 kV/±4 kV) with additional input filtering as shown below.
5. It is recommended that a fuse be used on the input of a power supply for
protection. For the MPM-05S-xx series, a 1.0A/250 VAC slow blow should
be used.
The diagram below illustrates a typical application connection of the MPM-05S series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The recommended
fuse is a 1.0A/250V slow blow and for the NTC, a 5D-9.
2. An external MOV is required on the input to protect the unit in the event of a surge.
A S14K350 or equivalent is recommended.
3. Recommended output filtering capacitors are:
C1
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
MPM-05S-03
MPM-05S-05
MPM-05S-09
MPM-05S-12
MPM-05S-15
MPM-05S-24
Typical Connection: With MACFM-02A Input Module (See note 4)
C2
330 µF/10V
330 µF/10V
120 µF/10V
120 µF/25V
68 µF/25V
68 µF/35V
TVS
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
The output filtering capacitor (C2) is a high frequency, low resistance electrolytic
capacitor. Capacitor (C1) is ceramic. Voltage derating of capacitors should be 80%
or above.
4. Input noise and surge suppression modules are available for a number of MPD
AC/DC power supplies. An MPM-05S-xx connection with the MACFM-02A is
illustrated in the diagram at left. For pricing or full technical information on these
modules, please contact the factory.
Pin Connections
Pin
Function
Pin
Function
1
2
AC-Ground
AC-Neutral
3
4
8
AC-Line
-Vout
+Vout
Mechanical Dimensions
Derating Curve
Input Voltage Vs Load
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!