MPM-20SV Datasheet - Micropower Direct

MPM-20SVSeries
85 to 305 VAC Input, 20W
Miniature PC Mount
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 20W Output Power
• Universal 85-305 VAC Input
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
• EN 60950 Approved
• Six Single Output Models
Input Frequency
Input Current
• Meets EN 55022 B
• >300 kHour MTBF
• Compact PC Mount Case
Inrush Current
Leakage Current
Min.
Typ.
85
100
47
See Model Selection Guide
115 VAC
15.0
230 VAC
30.0
230 VAC/50 Hz
0.3
Max.
305
430
63
Units
VAC
VDC
Hz
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
Max.
Units
±10
%
%
%
%
%
mV Pk - Pk
A Pk
mA rms
Output
Parameter
Output Voltage
Output Current
Output Trim Range
Minimum Load
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
0
±2.0
±0.5
±1.0
50
15
80
±0.02
Continuous (Autorecovery)
Autorecovery
110
VIN = Min to Max
See Note 2
See Note 3
115 VAC
230 VAC
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overload Protection
100
mSec
%/°C
%
General
Parameter
Conditions
Input to Output, 60S
Input to FG, 60S
Isolation Voltage
Switching Frequency
Min.
3,000
2,000
Typ.
Max.
Units
VAC
65
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
Max.
-40
+25
+70
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
See Mechanical Diagram On Page 4
Non-Conductive Black Plastic (UL94-V0)
4.22 Oz (120g)
Reliability Specifications
Parameter
MTBF
Lead Temperature, See Note 4
Safety Standards
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
300
Wave Solder
Hand Solder
UL 60950, EN 60950
Class I
www.micropowerdirect.com
Max.
260
360
Units
kHours
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output
Current (A)
Voltage
Current
Power
Over Volt.
Protection
Capacitive
Load
(µF, Max)
Efficiency
(%, Typ)
115 VAC
230 VAC
(VDC)
(A Max.)
(W)
(VDC)
MPM-20SV-03
0.60
0.34
3.3
3.50
11.5
7.5
48,000
75
MPM-20SV-05
0.60
0.34
5.0
3.50
17.5
7.5
12,240
78
MPM-20SV-09
0.60
0.34
9.0
2.10
20.0
12.0
5,600
79
MPM-20SV-12
0.60
0.34
12.0
1.60
20.0
20.0
5,400
83
MPM-20SV-15
0.60
0.34
15.0
1.30
20.0
20.0
2,400
84
MPM-20SV-24
0.60
0.34
24.0
0.85
20.0
30.0
1,840
85
Notes:
1. Operation at no load will not damage the units, however, they
may not meet all specifications.
2. Load regulation is measured for an output change of 10% to
100% at nominal input line.
3. When measuring output ripple, it is recommended that an
external 0.1 µF high frequency ceramic capacitor be placed
in parallel with a 47 µF high frequency electrolytic capacitor
from the +VOUT pin to the -VOUT pin.
4. The max lead temp for wave soldering is ±5% for a time
period of 5 to 10S. For hand soldering, it is ±10% for 3 to 5S.
5. All units are rated for EN 55022 (CE/RE) class B without
external components.
6. All units are rated for EN 61000-4-4 (±2 kV) with the addition of the MOV shown in the typical connection below. They
will meet EN 61000-4-4 (±4 kV) with the additional input
components shown in the typical connection diagram shown
on page 3.
7. All units are rated for EN 61000-4-5 (±1 kV/±2 kV) with the addition of the MOV shown in the typical connection below. They will
meet EN 61000-4-5 (±2 kV /±4 kV) with the input components
shown in the typical connection diagram on page 3.
8. It is recommended that a fuse be used on the input of a power
supply for protection. For the MPM-20SV-xx series, a
3.15A/300 VAC slow blow should be used.
MPD offers a wide variety of input protection and
filtering modules for use with our AC & DC power
modules. The MACFM-02A may be used with
the MPM-20SV, as shown on page. Full datasheets for all our input modules are available on
our website, or call the factory for a more help.
Typical Connection
The diagram above illustrates a typical application connection of the MPM-20SV series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The
recommended fuse is a 3.15A/300 VAC slow blow.
2. All units are rated for EN 55022 (CE/RE) class B without external
components.
3. All units are rated for EN 61000-4-4 (±2 kV) with the addition of
the MOV shown in the typical connection above. They will meet
EN 61000-4-4 (±4 kV) with the additional input components
shown in the typical connection diagram shown on page 3.
4. All units are rated for EN 61000-4-5 (±1 kV/±2 kV) with the addition of the MOV shown in the typical connection above. They will
meet EN 61000-4-5 (±2 kV /±4 kV) with the input components
shown in the typical connection diagram on page 3.
5. If output noise levels lower than the specified limits are required,
the addition of C1 and C2 should be sufficient for most applications.
The recommended values are shown in the table at right. The
output filtering capacitor C2 is a high frequency, low resistance
electrolytic capacitor. Capacitor C1 is ceramic. Voltage derating
of capacitors should be 80% or above.
6. The TVS is added to protect circuits being powered from damage
if the module fails.
7. The trim resistors (R1 & R2) are used to adjust the output voltage
level up or down. If this is not required, the trim pin should be
left open. See page 4 for details on using the trim function.
Derating Curve
Model
C1
C2
TVS
MPM-20SV-03
1.0 µF/50V
330 µF/10V
SMBJ7.0A
MPM-20SV-05
1.0 µF/50V
330 µF/10V
SMBJ7.0A
MPM-20SV-09
1.0 µF/50V
220 µF/25V
SMBJ12A
MPM-20SV-12
1.0 µF/50V
220 µF/25V
SMBJ20A
MPM-20SV-15
1.0 µF/50V
220 µF/25V
SMBJ20A
MPM-20SV-24
1.0 µF/50V
220 µF/35V
SMBJ30A
Input Voltage Vs Load
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
Conditions
Criteria
EN 55022
EN 55022
ESD
EN 61000-4-2
B
RS
EN 61000-4-3
A
B
B
B
B
A
A
B
EFT
EN 61000-4-4
Surge
EN 61000-4-5
CS
PFM
Voltage Dips, Short, Interruptions
See Note 1
See Note 2
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Level
Class B
Class B
±8 kV Air
±6 kV Contact
10V/m
±2 kV
±4 kV
±1 kV/±2 kV
±2 kV/±4 kV
10V rms
10A/m
0% - 70%
Notes:
1. To meet the requirements of EN 610004-4 (±4 kV), external components are
needed. This can be done discretely (as
shown below), or with the addition of the
MACFM-02A. Contact the factory for more
information.
2. To meet the requirements of EN 61000-4-5
(±2 kV/ ±4 kV ), external components are
needed. This can be done discretely (as
shown below), or with the addition of the
MACFM-02A. Contact the factory for more
information.
Typical Connection: With Input Protection/Filtering Components
The diagram above illustrates a typical connection of the MPM-20SV series. 5. Suggested component values are:
The input components are required to meet the more stringent EFT/Surge levels
Component
MPM20SV-03 MPM20SV-05 MPM20SV-09 MPM20SV-12 MPM20SV-15 MPM20SV-24
of EN 61000-4 (see notes for EMC Characteristics table above). Some notes on
3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC
Fuse
these components are:
MOV
S14K350
S14K350
S14K350
S14K350
S14K350
S14K350
1. It is recommended that an external fuse be used. The recommended fuse
size is a 3.15A/300 VAC slow blow.
0.1 µF/310V
0.1 µF/310V
0.1 µF/310V
0.1 µF/310V
0.1 µF/310V
0.1 µF/310V
CX
2. An external MOV is recommended on the input to protect the unit in the event
LDM
4.7 µH/2A
4.7 µH/2A
4.7 µH/2A
4.7 µH/2A
4.7 µH/2A
4.7 µH/2A
of a surge. A recommended value is given in the table at right.
LCM
10 mH
10 mH
10 mH
10 mH
10 mH
10 mH
3. The output filtering capacitors (C1 & C2) will reduce the output noise below
1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC
CY1/CY2
specified levels. Recommended values are given in the table on page 2.
4. The TVS is added to protect circuits being powered from damage if the module
6. Input protection and filtering modules are available for a number of MPD AC/DC power supplies. For use with the MPM-20SV product series,
fails. A recommended value for each model is given in the table on page 2.
the MACFM-02A filter module is recommended. A typical connection diagram and board layout with this module is shown in the figures
below. For pricing or full technical information on the MACFM-02A (or any of our other modules) please contact the factory.
Typical Board Layout: With External Filter Module
Typical Board Layout: With External Filter Module
1. The width of circuit traces should be a minimum of 3 mm.
2. The distance between traces should be a minimum of 6 mm.
3. The distance between a trace and ground should be a minimum of 6 mm.
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
External Trim
www.micropowerdirect.com
If not used, the Trim pin should be left open. Please contact the factory for more information.
External Trim Notes:
An external resistor can be used to adjust the converter
output up or down by about 10%. The connection is shown
in the diagram at left. The required resistor value is
calculated by the formulas:
Trim UP = RTRIM = A $-R2 - R3
R2 A
Where A =
Trim Down = RTRIM = A $-R1 - R3
R1 A
VREF
$ R1
VTRIM - VREF
Where A = VTRIM VREF $ R2
VREF
Where:
RTRIM =
VTRIM =
The value of the external trim
resistor
The amount of voltage
adjustment required
The values for R1, R2, R3 and VREF are given in
the table below.
Output Voltage (VDC)
3.3
5.0
9.0
12
15
24
R1
3.30 k⍀
3.30 k⍀
7.50 k⍀
3.83 k⍀
7.50 k⍀
8.66 k⍀
R2
1.98 k⍀
3.30 k⍀
2.87 k⍀
1.00 k⍀
1.50 k⍀
1.00 k⍀
R3
1.00 k⍀
1.00 k⍀
1.00 k⍀
1.00 k⍀
1.00 k⍀
1.00 k⍀
VREF
1.24 V
2.50 V
2.50 V
2.50 V
2.50 V
2.50 V
Mechanical Dimensions
Pin Connections
Pin
Function
1
AC-Ground
2
AC-Neutral
3
AC-Line
4
-VOUT
8
+VOUT
Trim
VOUT Trim
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•