MPD C6001RU

C6000RU
Series
Isolated, 60W
Ultra-Wide 4:1Input
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 60W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• -40ºC to +85ºC Operation
• Adjustable Output
• Remote ON/OFF
• >888 kHour MTBF
• Industry Standard Pin-Out
Input
Parameter
Input Voltage Range
Under Voltage Shutdown
Input Filter
Start Up Time
Conditions
Min.
24 VDC Input
9.0
48 VDC Input 18.0
24 VDC Input
48 VDC Input
␲ (Pi) Filter
Typ.
24.0
48.0
8.0
15.0
Max.
36.0
75.0
Units
VDC
VDC
70
mSec
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
Ripple & Noise, See Note 2
Transient Recovery Time, See Note 3
Transient Response Deviation
Output Over Voltage Protection
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±1.0
For Vin Min to Max
Iout = 25% to 100%
Max.
±0.5
±0.5
75
Units
%
%
%
mV P-P
µSec
%
±0.02
%/°C
Max.
Units
VDC
M⍀
pF
kHz
300
±5.0
See Model Selection Guide
50% Load Step Change
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off, See Note 4
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Conditions
Min.
1,500
1,000
Typ.
1,200
300
Min.
Typ.
Max.
Units
Open or 3.5 to 12 VDC
Short or 0.0 to 0.7 VDC
20
mA
Referenced to Negative Input (pin 2)
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
-55
See Derating Curve
RH, Non-condensing
Max.
+85
+105
+125
Units
°C
°C
°C
95
%
2.0 x 2.0 x 0.50 Inches (50.8 x 50.8 x 12.70 mm)
Nickel Coated Copper with Non-Conductive Base
3.63 Oz (103g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
888
Typ.
Max.
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (0.1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
C6001RU
C6002RU
C6003RU
C6004RU
C6011RU
C6012RU
C6013RU
C6014RU
Voltage (VDC)
Nom.
24
24
24
24
48
48
48
48
Range
9 - 36
9 - 36
9 - 36
9 - 36
18 - 75
18 - 75
18 - 75
18 - 75
Output
Current (mA)
Full-Load
2,437
3,086
2,976
2,941
1,188
1,506
1,488
1,453
Voltage
Current
Current
(VDC)
(A, Max)
(A, Min
No-Load
70
80
100
90
10
10
10
10
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
14.00
12.00
5.00
4.00
14.00
12.00
5.00
4.00
Efficiency
(Typ %)
Over
Capacitive
Voltage
Load
Protection
(µF Max)
(VDC)
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
83
85
88
89
85
87
88
90
3.9
6.2
15
18
3.9
6.2
15
18
47,000
36,000
4,700
2,200
47,000
36,000
4,700
2,200
Fuse Rating
Slow-Blow
(mA)
7,500
7,500
7,500
7,500
5,000
5,000
5,000
5,000
External Trim
For heatsink option, add suffix “H” to model number (i.e. C6003RU-H)
A simple external circuit may be used
to adjust the converter output. To adjust
the output DOWN, connect a 5%, 3W
resistor between the plus output pin
and the Vout trim pin. To adjust the
output UP, connect a 5%, 3W resistor
between the minus output pin and the
Vout trim pin.
For UP/Down trimming capability, connect a 10 kW potentiometer between
the plus and minus outputs with the
wiper arm connected to the Vout
trim pin.
The range for the external trim is
about ±10%.
Notes:
1. For 3.3 VDC output models, the maximum load regulation is ±0.8%.
2. When measuring output ripple, it is recommended that external 1.0 µF & 10 µF capacitors be placed in parallel
from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units.
3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%.
4. If the on/off pin is left open, the unit operates. If grounded, the unit will shut off.
5. Sense pins should be connected to the output load or to the corresponding output pin.
6. No load operation will not damage these units, but they may not meet all spec’s.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the
correct rating.
Derating Curve (3.3VDC, 5 VDC & 12 VDC Models)
Mechanical Dimensions
Derating Curve (15 VDC Models)
Pin Connections
Pin
Function
Pin
Function
1
2
3
4
+VIN
-VIN
On/Off
-Sense
5
6
7
8
+Sense
+VOUT
-VOUT
Trim
MicroPower Direct
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]