Flyback transformers for 30 Watt PoE applications
•
Operating Frequency 250KHz with input voltage 36 to 72 Volts
•
Isolation 1500Vrms, 60 seconds (Pri, Aux to Sec)
•
Operating Temperature -40ºC to +125ºC
•
RoHS Compliant Product
•
Custom Design Available
ELECTRICAL PARAMETERS @ 25°C
Part Number
Power
(W)
P620F-
DCR
Pri OCL
(μH)
Pri LL
(μH MAX)
(mΩ MAX)
±10%
Pri
Sec
Aux
Turns Ratio
Output
Sec
±5%
Pri:Sec
Pri:Aux
V/A
33
30
42
0.070
0.0023
0.22
3.00
1 : 0.09
1 : 0.33
3.3 / 9
50
30
42
0.069
0.0050
0.225
1.60
1 : 0.14
1 : 0.33
5.0 / 6
12
30
42
0.061
0.0150
0.195
0.55
1 : 0.33
1 : 0.33
12 / 2.5
19
30
42
0.060
0.0370
0.195
0.43
1 : 0.56
1 : 0.33
19.5 / 1.5
24
30
42
0.060
0.0550
0.195
0.31
1 : 0.67
1 : 0.33
24 / 1.25
Note:
1.
Primary OCL measured @ 250KHz 0.7Vrms
2.
Primary Leakage L measured @ 250KHz 0.7Vrms with 7-8-9-10-11-12 shorted
3.
DCR measured with windings in parallel
4.
Hi-pot: 1500Vrms, 1mA, 60s (Pri, Aux to Sec); 1800Vrms, 1mA, 5s (Pri, Aux, and Core to Sec); 500Vrms, 1mA, 5s (between Pri, Aux, and Core)
5.
Polarity: 1, 2, 5, 10, 11, and 12 are in phase
6.
Ipk: 2.6Adc, ΔL < 10% from initial value
DIMENSIONS
Product performance is limited to specified parameters. Data is subject to change without prior notice.
Tel: 310-325-1043
Fax: 310-325-1044
SCHEMATIC
Dimensions
Unless otherwise specified, all tolerances are:
inch: .XX : ±0.010 .XXX : ±0.005
mm: X,X : ±0,254 X,XX : ±0,13
www.mpsind.com
[email protected]