120W AC-DC Single Output Medical Adaptor GSM120B series EN 60601-1 IEC 60601-1 8 Features Applications Universal AC input / Full range 2 pole AC inlet IEC320-C8 Built-in active PFC function, PF>0.93 High efficiency up to 91.5% Low leakage current <100 A Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case Medical safety approved (2 x MOPP between primary to secondary) Class Ⅱ power (without earth pin) LED indicator for power on No load power consumption<0.15W ErP step2 compliant (level V) Meet EISA 2007 (Energy Independence and Security Act) 100% full load burn-in test Suitable for BF application with appropriate system consideration 3 years warranty Mobile clinical workstation Oral irrigator Portable hemodialysis machine Breath Machine Medical computer monitor Description GSM120B is a highly reliable, 120W single-output green medical adaptor series. This product is equipped with a 2-pin (no FG) standard IEC320-C8 power plug, adopting the input range from 80VAC to 264VAC. The entire series supplies different output voltages between 12VDC and 48VDC that can satisfy the demands for various kinds of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra low leakage current (<100 A), fitting the medical devices in direct electrical contact with the patients. With the efficiency up to 91.5% and the extremely low no-load power consumption below 0.15W, the design of GSM120B observes the latest energy regulation (Level V); the supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GSM120B is approved with the international medical safety certificates. Model Encoding GSM120 B 12 - R7B DC plug type Output voltage IEC320-C8 AC inlet Output wattage Series name File Name:GSM120B-SPEC 2015-02-03 120W AC-DC Single Output Medical Adaptor GSM120B series SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT 48V 20V 24V 7A 6A 5A 2.5A CURRENT RANGE 0 ~ 8.5A 0 ~ 7A 0 ~ 6A 0 ~ 5A 0 ~ 2.5A RATED POWER (max.) 102W 120W 105W 120W 120W RIPPLE & NOISE (max.) Note.3 120mVp-p 150mVp-p 180mVp-p 200mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% LINE REGULATION Note.5 ±1.0% ±5.0% ±1.0% ±5.0% ±5.0% ±1.0% ±4.0% ±3.0% ±1.0% ±3.0% ±2.5% ±1.0% ±2.5% 90% 91.5% ±5.0% Note.6 1500ms, 30ms / 230VAC 2000ms, 30ms / 115VAC at full load HOLD UP TIME (Typ.) VOLTAGE RANGE 20ms / 230VAC 20ms / 115VAC at full load 80 ~ 264VAC 113 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93 / 230VAC EFFICIENCY (Typ.) 88% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.4A / 115VAC OVER VOLTAGE PF>0.97 / 115VAC at full load 89% 35A / 115VAC 70A / 230VAC Touch current < 100 A/264VAC 105 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY -30 ~ +60℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing SAFETY STANDARDS SAFETY & ISOLATION LEVEL WITHSTAND VOLTAGE EMC (Note. 7) ISOLATION RESISTANCE 89% 0.7A / 230VAC OVER TEMPERATURE ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION NOTE GSM120B48-R7B GSM120B48 15V OVERLOAD CONNECTOR GSM120B24-R7B GSM120B24 Note.2 12V LEAKAGE CURRENT(max.) OTHERS GSM120B20-R7B GSM120B20 8.5A SETUP, RISE TIME PROTECTION GSM120B15-R7B GSM120B15 RATED CURRENT LOAD REGULATION INPUT GSM120B12-R7B GSM120B12 -40 ~ +85℃, 10 ~ 95% RH ±0.03% / ℃ (0 ~ 40℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1 / ES60601-1-11, TUV EN60601-1 / EN60601-1-11 approved Primary-Secondary: 2xMOPP I/P-O/P: 4KVAC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH EMC EMISSION EMC IMMUNITY Compliance to EN55011(CISPR11) class B, EN61000-3-2,3, FCC PART 15 class B MTBF DIMENSION 372K hrs min. MIL-HDBK-217F(25℃) 167*67*35mm (L*W*H) 0.6Kg; 20pcs/13,0Kg/0.9CUFT Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A PACKING PLUG See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/ 7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) File Name:GSM120B-SPEC 2015-02-03 GSM120B 120W AC-DC Single Output Medical Adaptor Derating Curve series Static Characteristics 100 100 90 80 60 70 LOAD (%) LOAD (%) 50 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) 60 50 40 80 90 AMBIENT TEMPERATURE (℃) 100 110 120 140 160 180 200 240 264 INPUT VOLTAGE (VAC) 60Hz Mechanical Specification 35 220 Case No. Unit:mm UL2464 16AWGx4C 1000±50mm for 12V UL2464 18AWGx4C 1200±50mm for 15V ~ 48V 167 30 3mm 67 23 14 POWER LED Plug Assignment Standard plug (all models) R7B PIN NO. OUTPUT 2 1 3 4 1,4 +V 2,3 -V Installation Manual Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html File Name:GSM120B-SPEC 2015-02-03