6W AC-DC High Reliability Medical Adaptor GSM06E series EN 60601-1 IEC 60601-1 8 ■ Features Universal AC input / Full range 2 pole EURO plug Medical safety approved (2 × MOPP between primary to secondary) Suitable for BF application with appropriate system consideration Low leakage current <50μA No load power consumption<0.3W Energy efficiency Level Ⅴ Comply with EU ErP Class Ⅱ power (without earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case Optional lock type DC plug 100% full load burn-in test 3 years warranty ■ Applications Blood glucose meter Blood pressure meter Nebulizer Inhaler Portable medical device ■ Description GSM06E is a highly reliable, 6W wall-mounted style single-output green medical adaptor series. This product is equipped with a 2-pin (no FG) standard European power plug, adopting the input range from 85VAC to 264VAC. The entire series supplies different output voltages between 5VDC and 24VDC that can satisfy the demands for various kinds of miniature medical devices. The circuitry design meets the international medical standards (2 x MOPP), having an ultra low leakage current (<50μA), fitting the medical devices in direct electrical contact with the patients. With the efficiency up to 82% and the extreme low no-load power consumption below 0.3W. GSM06E is compliant with EU ErP. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GSM06E is approved with the international medical safety certificates. ■ Model Encoding GSM 06 E 05 - P1J DC plug type { P1J : Plug for standard model, 2.1ψ × 5.5ψ ×11mm, c+, tuning fork type Optional plug type available by customer requested Output voltage European 2 pin AC plug Output wattage Series name File Name:GSM06E-SPEC 2015-05-12 GSM06E 6W AC-DC High Reliability Medical Adaptor series SPECIFICATION GSM06E05-P1J GSM06E06-P1J GSM06E07-P1J GSM06E09-P1J GSM06E12-P1J GSM06E15-P1J GSM06E18-P1J GSM06E24-P1J ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT GSM06E05 Note.2 5V GSM06E06 GSM06E07 GSM06E09 GSM06E12 GSM06E15 GSM06E18 GSM06E24 6V 7.5V 9V 12V 15V 18V 24V 0.25A RATED CURRENT 1.2A 1A 0.8A 0.66A 0.5A 0.4A 0.33A CURRENT RANGE 0 ~ 1.2A 0 ~ 1A 0 ~ 0.8A 0 ~ 0.66A 0 ~ 0.5A 0 ~ 0.4A 0 ~ 0.33A 0 ~ 0.25A RATED POWER 6W 6W 6W 6W 6W 6W 6W 6W RIPPLE & NOISE (max.) Note.3 50mVp-p 50mVp-p 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 180mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±5.0% ±5.0% ±5.0% ±5.0% ±5.0% ±4.0% LINE REGULATION Note.5 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION Note.6 ±5.0% ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% 74% 76% 77% 79% 80% 82% SETUP, RISE, HOLD UP TIME 1000ms, 50ms, 12ms at full load 85 ~ 264VAC 120 ~ 370VDC VOLTAGE RANGE INPUT FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 68% AC CURRENT INRUSH CURRENT (max.) 0.18A / 100VAC LEAKAGE CURRENT(max.) OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 7) EMC EMISSION EMC IMMUNITY MTBF OTHERS CONNECTOR NOTE 74% 30A / 230VAC Touch current < 50μA/264VAC >105% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 110 ~ 140% rated output power Protection type : Clamp by zener diode 0 ~ +50℃(Refer to "Derating Curve") 20% ~ 90% RH non-condensing -20 ~ +85℃, 10 ~ 95% RH ±0.04% / ℃ (0 ~ 40℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes IEC60950-1, TUV EN60601-1, EN60601-1-11 approved I/P-O/P:5656VDC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55011, EN61000-3-2,3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2 medical level, criteria A DIMENSION PACKING PLUG 500Khrs min. MIL-HDBK-217F(25℃) 32*66*42.5mm (L*W*H) 100g ; 90pcs / 10Kg / CARTON See page 3 ; Other type available by customer requested CABLE See page 3 ; Other type available by customer requested 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 0% to 100% rated load. 7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:GSM06E-SPEC 2015-05-12 GSM06E 6W AC-DC High Reliability Medical Adaptor Derating Curve series Static Characteristics 100 100 LOAD (%) LOAD (%) 90 70 80 70 60 50 40 0 10 20 30 40 50 85 AMBIENT TEMPERATURE (℃) 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz Mechanical Specification Plug Assignment Unit:mm Standard plug: P1J 34.5±1 P1J NAME PLATE 4ψ 13.6 P/N OUTPUT CENTER + 18.3 19.8 18 Optional lock type plug: P2S SWITCHCRAFT S761K plug equivalent UL2468 22AWG 1220 +150/-0mm for 5~9V UL2468 24AWG 1830 +150/-0mm for 12~24V 19±0.5 62.5±1 42.5±1 66±1 11 C"+" 32±1 ID 2.1 x OD 5.5 Installation Manual Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html File Name:GSM06E-SPEC 2015-05-12