GS280 series

GS280
280W AC-DC Industrial Adaptor
series
■ Features :
Universal AC input / Full range
Built-in active PFC function
No load power consumption<0.5W
Energy efficiency Level Ⅴ
Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP
3 pole AC inlet IEC320-C14
Class I power (with earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Fanless design, cooling by free air convection
LED indicator for power on
2 years warranty
(only for 12V/15V)
SPECIFICATION
GS280A12-C4P
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
GS280A12
Note.2 12V
PROTECTION
NOTE
GS280A24-C4P
GS280A48-C4P
GS280A20
20V
GS280A24
24V
GS280A48
48V
18.5A
16A
13A
11.67A
5.84A
0 ~ 18.5A
0 ~ 16A
0 ~ 13A
0 ~ 11.67A
0 ~ 5.84A
RATED POWER (max.)
222W
RIPPLE & NOISE (max.) Note.3 120mVp-p
240W
260W
280.08W
280.32W
120mVp-p
150mVp-p
280mVp-p
280mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±4.0%
±3.0%
±2.0%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±5.0%
±5.0%
±4.0%
±3.0%
±2.0%
93%
94%
SETUP, RISE TIME
Note.6 2000ms, 20ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.7 90 ~ 264VAC
16ms / 230VAC
2000ms, 20ms / 115VAC at full load
16ms / 115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95 / 230VAC
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
3A / 115VAC
PF>0.98 / 115VAC at full load
89.5%
92%
1.5A / 230VAC
120A / 230VAC
LEAKAGE CURRENT(max.)
1.5mA / 240VAC
OVERLOAD
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +60℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 8)
EMC EMISSION
EMC IMMUNITY
CONNECTOR
GS280A20-C4P
GS280A15
15V
CURRENT RANGE
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OTHERS
GS280A15-C4P
RATED CURRENT
LOAD REGULATION
INPUT
(except for 48V)
-40 ~ +85℃, 10 ~ 95% RH
±0.03% / ℃ (0~40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
PACKING
PLUG
173.6Khrs min. MIL-HDBK-217F(25℃)
220*95*46mm (L*W*H)
1.25Kg; 12pcs/16Kg/1.27CUFT
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
MTBF
DIMENSION
1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GS280-SPEC 2015-06-01
GS280
280W AC-DC Industrial Adaptor
Mechanical Specification
Case No. GS280A
46
series
Unit:mm
220
POWER LED
UL2464 16AWGx4C 1000 ± 50mm
50 ± 3mm
95
4
3
2
1
Plug Assignment
,
Standard power supply model s male connector : Housing AMP 1-480702-0 with inner pin 9848TP (6.35mm), or equivalent
Female connector (not provided with the power supply) : Housing AMP 1-480703-0 with inner pin 9848TR (6.35mm), or equivalent
C4P
PIN NO. OUTPUT
4
3
2
1
1,2
+V
3,4
-V
-V connected to AC FG
Female plug(customer side, not provide with the power supply): AMP 1-480703-0 equivalent
Derating Curve
Static Characteristics
100
100
230VAC for others
LOAD (%)
LOAD (%)
90
80
110VAC for
12V~15V
60
50
40
80
70
60
50
20
-30
40
0
10
20
30 35 40
50
AMBIENT TEMPERATURE (℃)
60
70
(HORIZONTAL)
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GS280-SPEC 2015-06-01