GS220 220W AC-DC Industrial Adaptor series ■ Features : Universal AC input / Full range Built-in active PFC function No load power consumption<0.5W Energy efficiency Level Ⅴ Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP 3 pole AC inlet IEC320-C14 Class I power (with earth pin) Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case LED indicator for power on 2 years warranty (except for 48V) SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT PROTECTION NOTE GS220A24-R7B GS220A48-R7B GS220A12 GS220A15 15V GS220A20 20V GS220A24 24V GS220A48 48V 15A 13.4A 11A 9.2A 4.6A CURRENT RANGE 0 ~ 15A 0 ~ 13.4A 0 ~ 11A 0 ~ 9.2A 0 ~ 4.6A RATED POWER (max.) 180W RIPPLE & NOISE (max.) Note.3 80mVp-p 201W 220W 221W 221W 100mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±4.0% ±3.0% ±2.0% LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±5.0% ±5.0% ±4.0% ±3.0% ±2.0% 93.5% 94.5% SETUP, RISE TIME Note.6 2000ms, 20ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.7 90 ~ 264VAC 20ms / 230VAC 2000ms, 20ms / 115VAC at full load 20ms / 115VAC at full load 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.91 / 230VAC EFFICIENCY (Typ.) 90% AC CURRENT (Typ.) INRUSH CURRENT (max.) 4A / 115VAC PF>0.98 / 115VAC at full load 90% 92% 2A / 230VAC 120A / 230VAC LEAKAGE CURRENT(max.) 1.5mA / 240VAC OVERLOAD 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER VOLTAGE OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY -30 ~ +60℃ (Refer to "Derating Curve") 20% ~ 90% RH non-condensing SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 8) EMC EMISSION EMC IMMUNITY CONNECTOR GS220A20-R7B RATED CURRENT ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION OTHERS GS220A15-R7B Note.2 12V LOAD REGULATION INPUT GS220A12-R7B -40 ~ +85℃, 10 ~ 95% RH ±0.03% / ℃ (0~50℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved I/P-O/P: 3KVAC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A PACKING PLUG 191.3K hrs min. MIL-HDBK-217F(25℃ ) 210*85*46mm (L*W*H) 1.1Kg; 12pcs/14.2Kg/0.73CUFT See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested MTBF DIMENSION 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. 8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:GS220-SPEC 2015-06-01 GS220 220W AC-DC Industrial Adaptor Mechanical Specification Case No.961A 46 series Unit:mm 210 UL2464 16AWGx4C 1000 ± 50mm 30±3mm POWER LED 85 23 14 Plug Assignment Standard plug : power DIN 4 pin with lock type, KYCON KPPX-4P equivalent R7B PIN NO. OUTPUT 2 1 3 4 1,4 +V 2,3 -V AC FG -V connected to AC FG Derating Curve Static Characteristics 100 230VAC 100 90 For others 80 LOAD (%) LOAD (%) 80 100VAC for others 110VAC for 12~15V 60 50 40 For 12~15V 70 60 50 20 -30 40 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GS220-SPEC 2015-06-01