MEANWELL GS120A12-R7B

GS120
120W AC-DC Single Output Desktop
series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.97
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
Class power ( with earth pin)
LED indicator for power on
No load power consumption<0.5W
ErP step2 compliant
Meet EISA 2007(Energy Independence and Security Act)
2 years warranty
TUV
Rheinland
Product Safety
SPECIFICATION
GS120A12-R7B
GS120A15-R7B
GS120A20=R7B,P1M
GS120A24=R7B,P1M
GS120A48=R7B,P1M
DC VOLTAGE
GS120A12
12V
GS120A15
15V
GS120A20
20V
GS120A24
24V
GS120A48
48V
RATED CURRENT
8.5A
7A
6A
5A
2.5A
CURRENT RANGE
0 ~ 8.5A
0 ~ 7A
0 ~ 6A
0 ~ 5A
0 ~ 2.5A
RATED POWER (max.)
102W
105W
120W
120W
120W
120mVp-p
150mVp-p
180mVp-p
240mVp-p
ORDER NO.
SAFETY MODEL NO.
OUTPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3
5.0%
5.0%
5.0%
3.0%
2.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
4.0%
3.0%
2.0%
Note.4
LOAD REGULATION
SETUP, RISE TIME
Note.6 2000ms, 30ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.7 85 ~ 264VAC
20ms / 230VAC
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
2500ms, 30ms / 115VAC at full load
20ms / 115VAC at full load
120 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
INPUT
geprUfre
Sicherheit
PF>0.97 / 230VAC
PF>0.99 / 115VAC at full load
R7B
87.5%
89%
89%
90%
91%
P1M
-----
-----
88.5%
89.5%
90.5%
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
PROTECTION OVER VOLTAGE
1.4A / 115VAC
0.7A / 230VAC
70A / 230VAC
0.75mA / 240VAC
105 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
RTH2 100 10
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +70 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
-40 ~ +85
, 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
I/P-O/P: 3KVAC
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022(CISPR22) ,EN61204-3 class B, CNS13438 class B, GB9254-1 class B, FCC PART 15
(Note. 5)
HARMONIC CURRENT
Compliance to EN61000-3-2,3, GB17625.1
OTHERS
CONNECTOR
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
DIMENSION
PACKING
PLUG
400.7Khrs min. MIL-HDBK-217F(25 )
167*67*35mm (L*W*H)
0.62Kg; 20pcs/13.4Kg/0.9CUFT
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS120-SPEC 2010-11-08
GS120
120W AC-DC Single Output Desktop
Mechanical Specification
Case No.GS120A
35
series
Unit:mm
UL2464 18AWGx4C 1200 50mm
167
30 3mm
67
23
14
POWER LED
35
UL2464 16AWGx2C 1200 50mm
167
30 3mm
67
11
Outside
C"+"
Inside
POWER LED
Plug Assignment
Standard plug(For 20V,24V,48V only)
Standard plug (all models)
11
P1M
R7B
PIN NO. OUTPUT
2
1
3
4
1,4
+V
2,3
-V
P/N
OUTPUT
CENTER
+
C"+"
ID 2.5 x OD 5.5
Outside
Inside
AC FG
-V connected to AC FG
Derating Curve
Static Characteristics
100
100
230VAC
85
80
80
70
100VAC
LOAD (%)
LOAD (%)
60
50
40
20
-30
10
20
30
40 45 50
60
AMBIENT TEMPERATURE ( )
70
(HORIZONTAL)
60
50
40
85
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GS120-SPEC 2010-11-08