Specification

GS36E
36W AC-DC Industrial Adaptor
series
■ Features :
Universal AC input / Full range
No load power consumption<0.3W
Energy efficiency Level Ⅴ
Comply with EU ErP
2 pole EURO plug
ClassⅡ power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
GS36E05-P1J
GS36E09-P1J
GS36E12-P1J
GS36E24-P1J
GS36E48-P1J
GS36E05
GS36E09
GS36E12
GS36E24
GS36E48
9V
12V
24V
48V
Note.2 5V
RATED CURRENT
4.5A
3.5A
3A
1.5A
0.75A
CURRENT RANGE
0 ~ 4.5A
0 ~ 3.5A
0 ~ 3A
0 ~ 1.5A
0 ~ 0.75A
RATED POWER (max.)
22.5W
36W
31.5W
36W
36W
RIPPLE & NOISE (max.) Note.3 90mVp-p
90mVp-p
100mVp-p
180mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±3.0%
±2.0%
±2.0%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION
Note.6 ±5.0%
±5.0%
±3.0%
±2.0%
±2.0%
85.5%
87.5%
SETUP, RISE, HOLD UP TIME 1000ms, 20ms, 15ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
INPUT
76.5%
AC CURRENT
INRUSH CURRENT (max.)
0.7A / 100VAC
84.5%
60A / 230VAC
0.25mA / 240VAC
OVERLOAD
110 ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode
-20 ~ +50℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 7)
EMC EMISSION
EMC IMMUNITY
NOTE
81.5%
LEAKAGE CURRENT(max.)
OVER VOLTAGE
CONNECTOR
47 ~ 63Hz
EFFICIENCY (Typ.)
PROTECTION
OTHERS
1000ms, 20ms, 15ms/115VAC at full load
±0.03% / ℃ (0 ~ 40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
TUV EN60950-1 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
PACKING
PLUG
692.3Khrs min. MIL-HDBK-217F(25℃)
79*54*33mm (L*W*H)
226g ; 60pcs / 15.5kg / CARTON
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
MTBF
DIMENSION
1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:GS36E-SPEC 2015-05-20
GS36E
36W AC-DC Industrial Adaptor
Mechanical Specification
series
38
Unit:mm
UL1185 16AWG 1000±50mm
60±10mm
70±10mm
C"+"
11±0.5mm
ID 2.1 x OD 5.5
NAME PLATE
Plug Assignment
33
79
Standard plug: P1J
54
P1J
Derating Curve
P/N
OUTPUT
CENTER
+
Static Characteristics
100
for 12~48V
90
LOAD (%)
LOAD (%)
100
70
for 5~9V
80
70
60
50
40
-20
10
20
30
40
AMBIENT TEMPERATURE (℃)
50
90
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GS36E-SPEC 2015-05-20