Model : - Meanwell

100W Dual Output Switching Power Supply
NED-100
series
MODEL:NED-100C
OUTPUT FUNCTION TEST
NO
1
2
3
4
5
6
7
8
9
10
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
RIPPLE & NOISE
V1: 120 mVp-p (Max )
V2: 80 mVp-p (Max )
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
V1: 19
V2: 23
OUTPUT VOLTAGE
ADJUST RANGE
CH1:11.4V ~13.2 V
I/P: 230 VAC
I/P:115VAC
O/P:MIN LOAD
Ta:25℃
9.211V~13.746 V /230vAC
9.358V~13.762V/115VAC
OUTPUT VOLTAGE
TOLERANCE
V1: -2 %~ +2% (Max)
V2: -3 %~ +3% (Max)
I/P:200VAC / 264 VAC
O/P:FULL/ 0 % LOAD
Ta:25℃
V1: 0.36 %~ 0.47%
V2:0.86 %~1.74 %
LINE REGULATION
V1: -0.5 %~+0.5 % (Max)
V2: -0.5 %~+0.5 % (Max)
I/P: 200 VAC ~ 264VAC
O/P:FULL LOAD
Ta:25℃
V1: -0.05%~
V2: 0 %~
V1: -1%~ 1 % (Max)
V2: -2%~ 2 % (Max)
I/P: 230 VAC
O/P:FULL ~MIN LOAD
Ta:25℃
V1: -0.05 %~ 0 %
V2:0.24 %~ 0.49 %
230VAC/ 2000 ms (Max)
115VAC/ 1200 ms (Max)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230 VAC/1424.671ms
115 VAC/905.873ms
230VAC/ 30 ms (Max)
115VAC/ 30 ms (Max)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230 VAC/7.813 ms
115 VAC/ 7.774 ms
230VAC/25 ms (TPY)
115VAC/20 ms (TYP)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230 VAC/31.216ms
115 VAC/28.328 ms
< +5%
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
TEST: 4.17 %
I/P: 230 VAC
O/P(1)FULL /Min LOAD
90%DUTY/1KHZ
(2)50% /Min LOAD
90%DUTY/1KHZ
Ta:25℃
306mVp-p
158mVp-p
LOAD REGULATION
SET UP TIME
RISE TIME
HOLD UP TIME
OVER/UNDERSHOOT TEST
DYNAMIC LOAD
V1: 1200 mVp-p
VERDICT
mVp-p
mVp-p
P
P
P
0%
0%
P
P
P
P
P
P
P
Model: NED-100C
Test Report
1 / 5
100W Dual Output Switching Power Supply
NED-100
series
INPUT FUNCTION TEST
NO
1
2
3
4
5
TEST ITEM
INPUT VOLTAGE RANGE
INPUT FREQUENCY RANGE
EFFICIENCY
INPUT CURRENT
INRUSH CURRENT
SPECIFICATION
176AC~264VAC
47HZ ~63 HZ
NO DAMAGE OSC
80 % (TYP)
TEST CONDITION
I/P:TESTING
O/P:FULL LOAD
Ta:25℃
RESULT
VERDICT
134.112V~264 V
I/P:
LOW-LINE-3V= 173V
HIGH-LINE+15%= 300 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10MIN
( AC POWER ON/OFF NO DAMAGE )
TEST: OK
I/P: 200 VAC ~264 VAC
O/P:FULL~MIN LOAD
Ta:25℃
TEST: OK
P
P
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
82.97%
230 V/ 1.2A (Typ)
115 V/ 2 A (Typ)
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
I = 0.938A/ 230VAC
I =1.748 A/ 115VAC
230 V/45 A (Typ)
COLD START
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
I =38.601A/ 230VAC
P
P
P
PROTECTION FUNCTION TEST
NO
1
2
3
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
OVER LOAD PROTECTION
110%~150%
RATED OUTPUT POWER
I/P: 230 VAC/115VAC
O/P:TESTING
Ta:25℃
140%/230VAC
140%/ 115VAC
Hiccup Mode
I/P: 230 VAC/115VAC
O/P:MIN. LOAD
Ta:25℃
14.521V/230VAC
14.520V/115VAC
Hiccup Model
I/P: 264 VAC
O/P: FULL LOAD
Ta:25℃
NO DAMAGE
Hiccup Mode
OVER VOLTAGE PROTECTION
SHORT PROTECTION
CH1: 13.8V~15.8V
SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
VERDICT
P
P
P
Model: NED-100C
Test Report
2 / 5
NED-100
100W Dual Output Switching Power Supply
series
SAFETY TEST
NO
1
2
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
WITHSTAND VOLTAGE
I/P-O/P: 3 KVAC/min
I/P-FG:2 KVAC/min
O/P-FG:0.5KVAC/min
I/P-O/P: 3.6 KVAC/min
I/P-FG: 2.4 KVAC/min
O/P-FG: 0.6 KVAC/min
Ta:25℃
I/P-O/P:9.02 mA
I/P-FG:7.35mA
O/P-FG:9.61 mA
NO DAMAGE
P
I/P-O/P:500VDC>100MΩ
I/P-FG: 500VDC>100MΩ
O/P-FG:500VDC>100MΩ
I/P-O/P: 500 VDC
I/P-FG: 500 VDC
O/P-FG: 500 VDC
Ta:25℃
I/P-O/P:2.02 G Ω
I/P-FG:G 1.13Ω
O/P-FG:3.08G Ω
NO DAMAGE
P
ISOLATION RESISTANCE
3
GROUNDING CONTINUITY
FG(PE) TO CHASSIS
OR TRACE < 100 mΩ
40A / 2min
Ta:25℃
7 mΩ
4
LEAKAGE CURRENT
< 2mA / 240VAC
I/P: 264 VAC
O/P:Min LOAD
Ta:25℃
L-FG: 1.35 mA
N-FG: 1.4 mA
VERDICT
P
P
E.M.C TEST
NO
1
2
3
4
5
6
7
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
HARMONIC
EN61000-3-2
CLASS A
I/P: 230 VAC/50HZ
O/P:100% LOAD
Ta:25℃
PASS
EN55022
CLASS B
I/P: 230 VAC/50HZ
O/P:FULL/50% LOAD
Ta:25℃
PASS
Test by certified Lab
P
EN55022
CLASS B
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
PASS
Test by certified Lab
P
EN61000-4-2
LIGHT INDUSTRY
AIR:8KV / Contact:4KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
EN61000-4-4
LIGHT INDUSTRY
INPUT: 1KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
IEC61000-4-5
LIGHT INDUSTRY
L-N :1KV
L,N-PE:2KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
CONDUCTION
RADIATION
E.S.D
E.F.T
SURGE
VERDICT
P
P
P
P
Test by certified Lab & Test Report Prepare
Model: NED-100C
Test Report
3 / 5
100W Dual Output Switching Power Supply
NED-100
series
ENVIRONMENT TEST
NO
1
TEST ITEM
SPECIFICATION
TEMPERATURE RISE TEST
MODEL: NED-100C
1. ROOM AMBIENT BURN-IN: 1.5 HRS
I/P: 230 VAC O/P: FULL LOAD Ta= 33.8 ℃
2. HIGH AMBIENT BURN-IN: 2 HRS
I/P: 230 VAC O/P: FULL LOAD Ta= 36.9 ℃
TEST CONDITION
NO
2
3
4
RESULT
ROOM AMBIENT HIGH AMBIENT
Ta= 33.8 ℃
Ta= 36.9 ℃
63.9℃
65.4℃
Position
1
LF1
2
BD1
74.1℃
74.5℃
3
C5
69.3℃
70.5℃
4
D1
89.3℃
89.9℃
5
U1
92.0℃
91.3℃
6
Q1
72.9℃
73.3℃
7
C36
82.4℃
96.6℃
8
T1
92.2℃
94.4℃
9
L100
94.6℃
95.1℃
10
C205
77.8℃
78.4℃
11
C206
74.6℃
76.5℃
12
L200
87.8℃
86.6℃
13
C207
79.6℃
80.3℃
14
D100
107.0℃
107.8℃
15
C105
73.4℃
74.7℃
NO DAMAGE
1 HOUR ( MIN )
I/P: 230 VAC
O/P: 120% LOAD
Ta:25℃
TEST: OK
LOW TEMPERATURE
TURN ON TEST
TURN ON AFTER 2 HOUR
I/P: 230 VAC
O/P: 70 ﹪LOAD
Ta= -20 ℃
TEST:OK
HIGH HUMIDITY
HIGH TEMPERATURE
HIGH VOLTAGE
TURN ON TEST
AFTER 12 HOURS
IN CHAMBER ON
CONTROL
℃
I/P: 277 VAC
O/P:FULL LOAD
Ta= 45 ℃
TEST: OK
NO DAMAGE
+ 0.03 %(0~50℃)
HUMIDITY= 95 %R.H
OVER LOAD BURN-IN TEST
5
TEMPERATURE
COEFFICIENT
6
VIBRATION TEST
VERDICT
I/P: 230 VAC
O/P:FULL LOAD
1 Carton & 1 Set Operating at I/P: VAC NO LOAD
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:10min/sweep cycle
(4) Acceleration:2G
(5) Test Time:1 hour in each axis (X.Y.Z)
(6) Ta:25℃
P
P
P
P
+ 0.01 %(0~50℃)
P
TEST: OK
P
M.T.B.F & LIFE CYCLE CALCULATION
NO
1
2
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
CAPACITOR
LIFE CYCLE
NED-100C: SUPPOSE C105 IS THE MOST CRITICAL COMPONENT
I/P: 230 VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME= 98617 HRS
I/P: 230 VAC O/P:FULL LOAD Ta= 45 ℃ LIFE TIME= 27936 HRS
P
MTBF
MIL-HDBK-217F NOTICES2 PARTS COUNT
TOTAL FAILURE RATE: 320.7K HRS
P
Model: NED-100C
VERDICT
Test Report
4 / 5
100W Dual Output Switching Power Supply
NED-100
series
COMPONENT STRESS TEST
NO
1
2
3
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
Power Transistor
( D to S) or (C to E) Peak Voltage
Q1 Rated
900V 7A
I/P:High-Line +3V = 267 V
O/P: (1)Full Load input on/off
(2)Output Short
Ta:25℃
(1)800V
(2)856 V
Diode Peak Voltage
D100 Rated
200V 30 A
I/P:High-Line +3V = 267 V
O/P: (1)Full Load input on/off
(2)Output Short
Ta:25℃
(1)83.6V
(2)85.2V
C 5 Rated
220 uF /250 V
I/P:High-Line +3V =267 V
O/P: (1)Full Load input on/off
(2) Min load input on /Off
(1)183V
(2)180V
Input Capacitor Voltage
VERDICT
P
p
P
Ta:25℃
4
Control IC Voltage Test
U1 Rated
30 V
I/P:High-Line +3V =267 V
O/P:(1) Output Short
(2)O.L.P
Ta:25℃
(1)20.5V
(2) 20.3V
P
TEST RESULT
TESTER
REVIEW
APPROVAL
PASS
DANIEL GAO
SANFORD SU
VINCENT ZENG
12.10.30 A50-F031
Model: NED-100C
Test Report
5 / 5