Test Report: DAP-04
DALI-PWM Signal Converter
 DESIGN VERIFY TEST
Output Function Test
Input Function Test
Control Function Test
DAP-04
DALI-PWM Signal Converter
series
 DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO
1
2
3
TEST ITEM
SPECIFICATION
TEST CONDITION
NUMBER OF OUTPUT CHNNEL
4
I/P:230VAC
O/P:NO LOAD
Ta:25℃
4
I/P: 230VAC
O/P:FULL LOAD
Ta:25℃
994.8 Hz
OUTPUT SIGNAL (Typ)
OUTPUT PWM LOGIC
PWM 1KHZ ±1%
PWM active High / Low selection.
Short : Active High. Open : Active
Low. Factory setting is Active High.
4
DIMMING RANGE
1%~100%
RESULT
VERDICT
CHANNELS
P
P
I/P: 230V
O/P: 1%~100LOAD
Ta:25℃
ACTIVE HIGH:SHORT
ACTIVE LOW:OPEN
I/P:230VAC
O/P: 1%~100LOAD
Ta:25℃
TEST:OK
P
P
INPUT FUNCTION TEST
NO
1
2
3
4
5
6
7
TEST ITEM
INPUT VOLTAGE RANGE
INPUT FREQUENCY RANGE
AC CURRENT(Typ)
POWER CONSUMPTION(TYP)
INPUT SIGNAL
NO LOAD POWER CONSUMPTION
INRUSH CURRENT
SPECIFICATION
TEST CONDITION
RESULT
I/P:TESTING
O/P:FULL LOAD
Ta:25℃
80 V~ 305V
47HZ ~63 HZ
NO DAMAGE OSC
I/P:90 VAC ~305 VAC
O/P:FULL~MIN LOAD
Ta:25℃
TEST: PASS
277V/0.1A
230V/0.1 A
115V/0.1 A
I/P: 277VAC/230VAC/115VAC
O/P:FULL LOAD
Ta:25℃
I =0.013 A/ 277VAC
I =0.012 A/ 230VAC
I =0.013 A/ 115VAC
I/P:230 VAC
O/P:FULL LOAD
Ta:25℃
0.48 W
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
TEST : OK
I/P: 230 VAC
I/P: 115 VAC
O/P:NO LOAD
Ta:25℃
0.45 W /230V
0.37W /115V
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
12.9A/230V
T50=490us
P
I/P: 240 VAC
O/P:Min LOAD
Ta:25℃
L-FG:0.002mA
N-FG:0.002mA
P
90VAC~305VAC
0.5W
DALI or PUSH DIM
<0.5W
15A/230VAC
(twidth=500μ s measured at
50% Ipeak)
8
LEAKAGE CURRENT
< 0.5mA
VERDICT
P
P
P
P
P
Model: DAP-04
P
Test Report
2 / 9
DAP-04
DALI-PWM Signal Converter
series
CONTROL FUNCTION TEST
NO
1
TEST ITEM
REALY SWITCH
SPECIFICATION
240VAC / 8A, ON / OFF
control refer to DIM1
TEST CONDITION
RESULT
I/P: 240AC
O/P:FULL LOAD
Ta:25℃
Relay contact rating(max.) : 240VAC / 8A
VERDICT
resistive "Short" when DIM1 output duty
cycle >0 ; "Open" when DIM1 output duty
P
cycle=0
2
DALI DIMMING SOLUTION
DAP-04 with MEAN WELL's LED power supply
P
※Note: Choose a suitable cable for connecting the DAP-04 and DALI
controller and make sure the maximum voltage drop between these two
units should not be higher than 2V. (Maximum cable length for 1.5mm 2
cables is 300m.)
3
PUSH DIMMING SOLUTION
DAP-04 with MEAN WELL's LED power supply
P
※Note: Only use Normally Open Push Button without light indicator .
4
Dimming with LED PSU
ON/OFF
*The DAP-04 is equipped with a relay that can be used to turn ON/OFF
MEAN WELL LED PSUs. The relay is in the closed
position when the DIM1 generates dimming signal; the relay is in the open
P
position when there is no output signal on the DIM1.
Model: DAP-04
Test Report
3 / 9
DAP-04
DALI-PWM Signal Converter
series
*An additional magnetic switch is needed when the total input current of the
selected LED PSUs is higher than 8A or used with LED PSUs whose
inrush current is greater than 50A, please refer to the figure 2.
5
PUSH dim(primary side)
Function
Pushing time
No change of state
<0.05 sec.
Turn ON-OFF
0.1~1 sec.
Dimming up or down
1.5~10 sec.
Setting light to 100%
>11 sec.
P
_Maximum length of the cable, from push button to last driver, is 20 meter.
_Factory default dimming setting : 100%.
Every long pushing action will change the dimming direction
6
Description
dimmer
of
DALI
a.OSRAM MCU dimmer: (OSRAM DALI model: DALI MCU)
dimming control
RESULT
RANGE:1%~100%
OK
b. OSRAM BASIC
(OSRAM DALI model:DALI RC BASIC SO )
dimming control
RESULT
Short press: turn off the luminaire
OK
Long press: dimming function, light
intensity changes in every long
presses
OK
Model: DAP-04
Test Report
P
4 / 9
DALI-PWM Signal Converter
7
Combination of DALI and
PUSHDIM
function
DALI signal priority
Remove DALI signal
8
SYNCHRONIZATION
OPERATION
DAP-04
series
Description
Only DALI signal can be accepted be when there are DALI and
PUSHDIM signals connected.
Using ON/OFF the luminaire to do the verification.
Output will become full intensity automatically when DALI signal
is removed and there is not action in pushdim.
P
*DAP-04 provides 4-channel outputs; every channel controls up to 20 units
of MEAN WELL LED PSU.
The 4 channels can thus control up to 80 units of MEAN WELL LED PSU.
(Note. 1)
*The dimming percentage of the MEAN WELL LED PSUs controlled by the
same channel of DAP-04 is the same.
The dimming percentage per DAP-04 channel can be controlled
independently.
*The maximum allowable voltage drop between the DAP-04 and LED
PSUs should not be higher than 0.5V.
P
Model: DAP-04
Test Report
5 / 9
DAP-04
DALI-PWM Signal Converter
series
COMPONENT STRESS TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
Diode Peak Voltage
D100
Rated
1A/200V
I/P:High-Line +3V = 308V
O/P: (1)100% load
(1)
(2)
(3)
(2)1% load
(3)0% load
Ta:25℃
2
Input Capacitor Voltage
C5 Rated:
22u/450V
I/P:High-Line +3V = 308 V
O/P: (1)100% load
(2)1% load
(3)0% load
Ta:25℃
3
Control IC Voltage Test
PWM IC U302 Rated
1.8V~3.6V
4
Power Transistor Test
Q351 Rated :
300mA/60V
I/P:High-Line +3V = 308 V
O/P: (1)100% load
(2)1% load
(3)0% load
Ta:25℃
I/P:High-Line +3V = 308 V
O/P:(1)100% load
(2)1% load
(3)0% load
Ta:25℃
5
TOP SWITCHING STAND BY
POWER
U 1 Rated:
1040mA/700V
I/P:High-Line +3V = 308V
O/P:(1)100% load
(2)1% load
(3)0% load
Ta:25℃
111
111
111
VERDICT
V
V
v
P
(1)
(2)
(3)
438
438
439
V
V
V
P
(1)
(2)
(3)
3.4
3.4
3.4
V
V
V
P
(1)
(2)
(3)
10.8
1
0.5
V
V
V
P
(1)
(2)
(3)
576
576
576
V
V
V
P
Model: DAP-04
Test Report
6 / 9
DAP-04
DALI-PWM Signal Converter
series
 SAFETY & E.M.C. TEST
SAFETY TEST
NO
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
1
WITHSTAND VOLTAGE
EN 60950
I/P-O/P: 3.75KVAC/min
I/P-O/P: 4 KVAC/min
Ta:25℃
I/P-O/P: 1.42 mA
NO DAMAGE
VERDICT
P
2
ISOLATION RESISTANCE
I/P-O/P:500VDC>100MΩ
I/P-O/P: 500 VDC
Ta:25℃
I/P-O/P: 26 GΩ
NO DAMAGE
P
E.M.C TEST
NO
1
2
3
4
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
HARMONIC
EN61000-3-2
CLASS C
I/P:240VAC/230VAC/220VAC/60HZ
O/P:100%LOAD
Ta:25℃
PASS
EN55015
CLASS B
I/P:230 VAC (50HZ)
O/P:FULL/50% LOAD
Ta:25℃
PASS
EN55015
CLASS B
I/P: 230 VAC (50HZ)
O/P:FULL LOAD
Ta:25℃
PASS
Test by certified Lab
EN61000-4-2
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
CONDUCTION
RADIATION
E.S.D
INDUSTRY
AIR:8KV / Contact:4KV
5
E.F.T
EN61000-4-4
INDUSTRY
INPUT: 2KV
VERDICT
P
P
P
P
(AIR:8.8KV / Contact:4.4KV)
I/P: 230VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
P
(INPUT: 2.2KV )
6
SURGE
IEC61000-4-5
INDUSTRY
L-N :2KV
L,N-PE:4KV
I/P: 230VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
P
(L-N:2.2kV)
Model: DAP-04
Test Report
7 / 9
DAP-04
DALI-PWM Signal Converter
series
 RELIABILITY TEST
ENVIRONMENT TEST
NO
1
3
4
6
7
8
TEST ITEM
SPECIFICATION
TEMPERATURE RISE TEST
MODEL: DAP-04
1. ROOM AMBIENT BURN-IN:13 HRS
I/P: 230VAC O/P: FULL LOAD Ta= 29.7 ℃
2. HIGH AMBIENT BURN-IN: 5.5 HRS
I/P: 230VAC O/P: FULL LOAD Ta= 61.8 ℃
TEST CONDITION
Position
1
BD1
2
C5
38.5℃
70.7℃
3
D1
39.6℃
73.6℃
4
U1
42.8℃
75.9℃
5
TI COIL
35.3℃
68.1℃
6
D100
35.8℃
69.9℃
7
C101
34.7℃
68.0℃
8
U100
35.9℃
70.9℃
9
Q150
37.0℃
71.2℃
10
BD30
38.4℃
70.7℃
11
U3
37.9℃
70.0℃
12
U302
35.5℃
70.4℃
13
Q351
34.2℃
68.9℃
14
ZD35
32.8℃
67.4℃
TEST:OK
AFTER 12 HOURS
IN CHAMBER ON
CONTROL 60 ℃
I/P: 308 VAC
O/P:FULL LOAD
Ta= 60 ℃
TEST:OK
NO DAMAGE
HUMIDITY= 95 %R.H
HIGH HUMIDITY
HIGH TEMPERATURE
HIGH VOLTAGE
TURN ON TEST
THERMAL SHOCK TEST
VIBRATION TEST
P
I/P: 305VAC/100VAC
O/P: 100 ﹪LOAD
Ta= -35 ℃
TURN ON AFTER 2 HOUR
P
P
1.
2.
3.
4.
5.
Thermal shock Temperature: -45℃~ +90℃
Temperature change rate :25℃ / MIN
Dwell time low and high temperature : 30 MIN/EACH
Total test cycle:5 CYCLE
Input/Output condition: STATIC
OK
1.
2.
3.
4.
5.
Thermal shock Temperature: -35℃~ +65℃
Temperature change rate :25℃ / MIN
Dwell time low and high temperature : 30 MIN/EACH
Total test cycle:10 CYCLE
Input/Output condition: 230VAC/Full Load AC ON/OFF TEST
turn on 58sec;turn off 2sec
OK
1 Carton & 1 Set
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:12min/sweep cycle
(4) Acceleration:2G
(5) Test Time:60min in each axis (X.Y.Z)
(6) Ta:25℃
VERDICT
ROOM AMBIENT HIGH AMBIENT
Ta= 29.7 ℃
Ta= 61.8 ℃
37.7℃
70.1℃
NO
LOW TEMPERATURE
TURN ON TEST
STORAGE TEMPERATURE TEST
RESULT
P
P
TEST:OK
P
Model: DAP-04
Test Report
8 / 9
DAP-04
DALI-PWM Signal Converter
9
10
11
CAPACITOR
LIFE CYCLE
SUPPOSE C101
(1) I/P: 230VAC
(2) I/P: 230VAC
MTBF
MIL-HDBK-217F NOTICE S2 PARTS COUNT
TOTAL FAILURE RATE:246.9 KHRS
DMTBF/Accelerated Life Test
IS THE MOST CRITICAL COMPONENT
O/P:FULL LOAD Ta= 25 ℃ LIFE TIME
O/P:FULL LOAD Ta= 60 ℃ LIFE TIME
(1)
(2)
series
1086115 HRS
88320 HRS
P
P
Demonstration Mean Time Between Failure(Expected Life) : 30,000 hours @ Tcase 75 ℃
P
TEST RESULT
TESTER
REVIEW
APPROVAL
PASS
DANIEL GAO
SANFORD SU
VINCENT TSENG
12.10.30 A50-F031
Model: DAP-04
Test Report
9 / 9