LCM-40DA - Meanwell

Test Report: LCM-40DA
40W Multiple-Stage Output Current LED Power Supply
 DESIGN VERIFY TEST
Output Function Test
Input Function Test
Protection Function Test
Control Function Test
Component Stress Test
 SAFETY & E.M.C. TEST
Safety Test
E.M.C. Test
 RELIABILITY TEST
ENVIRONMENT TEST
LCM-40DA series
40W Mul t i pl e -St a ge O ut put Cur r ent LED Power Suppl y
 DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO
1
2
3
4
5
6
7
8
TEST ITEM
SPECIFICATION
TEST CONDITION
RIPPLE & NOISE
V1:700
I/P: 230VAC
O/P:FULL LOAD
Ta:25℃
350mA:
500mA:
600mA:
700mA:
900mA:
1050mA:
75.2
54.8
38.8
60.4
36.8
36.6
I/P: 230 VAC
O/P:MIN LOAD
Ta:25℃
350mA:
500mA:
600mA:
700mA:
900mA:
1050mA:
102.69
102.69
102.69
62.57
62.57
62.57
NO LOAD O/P VOLTAGE
RIPPLE CURRENT
CURRENT ACCURACY
SET UP TIME
RISE TIME
HOLD UP TIME
OVER/UNDERSHOOT
TEST
350mA:
500mA:
600mA:
700mA:
900mA:
1050mA:
mVp-p (Max )
100V~110V
100V~110V
100V~110V
60V~65V
60V~65V
60V~65V
±5%
±5%
230VAC:
230VAC:
230VAC:
< +5%
500
80
16
ms (Max)
ms (Max)
ms (TYP)
RESULT
VERDICT
mVp-p (Max )
mVp-p (Max )
mVp-p (Max )
mVp-p (Max )
mVp-p (Max )
mVp-p (Max )
V/230 VAC
V/230 VAC
V/230 VAC
V/230 VAC
V/230 VAC
V/230 VAC
P
P
I/P: 230VAC
O/P:LED LOAD
Ta:25℃
350mA:
500mA:
600mA:
700mA:
900mA:
1050mA:
±1.9
±2
±1.8
±1.7
±1.5
±1.5
%
%
%
%
%
%
P
I/P: 230VAC
O/P:MIN~MAX
Ta:25℃
350mA:±
500mA:±
600mA:±
700mA:±
900mA:±
1050mA:±
0.3
0.2
0.2
0.1
0.1
0.1
%
%
%
%
%
%
P
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
230VAC/
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
230VAC/
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
230VAC/
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
TEST:
388
ms
P
18
ms
P
23
ms
P
<5
%
P
Model: LCM-40DA
Test Report
2 / 9
LCM-40DA series
40W Mul t i pl e -St a ge O ut put Cur r ent LED Power Suppl y
INPUT FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
INPUT VOLTAGE RANGE
180VAC~295 VAC
I/P:TESTING
O/P:FULL LOAD
Ta:25℃
I/P:
RESULT
VERDICT
164 V~295V
TEST: OK
LOW-LINE-3V= 177 V
(PLEASE CHECK DERATING CURVE)
HIGH-LINE+10V=305 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10MIN
P
( AC POWER ON/OFF NO DAMAGE )
2
3
4
5
6
INPUT FREQUENCY
RANGE
47HZ ~63 HZ
NO DAMAGE
POWER FACTOR
EFFICIENCY
0.975
/ 230 VAC(TYP)
0.96
/ 277 VAC(TYP)
INRUSH CURRENT
TEST: OK
I/P: 230 VAC
I/P: 277 VAC
O/P:FULL LOAD
Ta:25℃
PF=
0.993
/ 230 VAC
PF=
0.991
/ 277 VAC
91.30
%
P
I/P: 230 VAC
O/P:LED:80V @500mA
Ta:25℃
91 % (TYP)
INPUT CURRENT
I/P: 200 VAC ~ 295 VAC
O/P:FULL~MIN LOAD
Ta:25℃
230V/
0.23
A (TYP)
277V/
0.2
A (TYP)
230V/
20
A (TYP)
(twidth=260us measured at 50%
Ipeak)
P
P
I/P: 230 VAC
I/P: 277 VAC
O/P:FULL LOAD
Ta:25℃
I=
0.219
A/ 230 VAC
I=
0.18
A/ 277 VAC
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
I=
18.2
A/ 230 VAC
I/P: 240 VAC
O/P:Min LOAD
Ta:25℃
L-FG:
0.003
mA
N-FG:
0.002
mA
P
I/P:180VAC
I/P:230VAC
I/P:277VAC
O/P:NO LOAD
Ta:25℃
<
<
<
0.429
0.457
0.497
W
W
W
P
T50=
255
P
us
P
COLD START
7
8
9
LEAKAGE CURRENT
NO LOAD CONSUMPTION
TOTAL
DISTORTION
HARMONIC
<
<
0.5
0.5
mA / 240 VAC
W
Total harmonic distortion will be
lower than 20% when output
I/P: 230 VAC
O/P:75% LOAD
THD:
8.63
/230VAC
THD:
11.82
/277VAC
loading is 75% or higher
I/P: 277 VAC
O/P:75%LOAD
Ta:25℃
P
PROTECTION FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
OVER VOLTAGE PROTECTION
CH1:110 V ~ 130 V
I/P: 230 VAC
I/P: 180 VAC
O/P:MIN LOAD
Ta:25℃
121.86V/ 230 VAC
122.09V/ 180VAC
Shut down Re- power ON
Model: LCM-40DA
VERDICT
P
Test Report
3 / 9
40W Mul t i pl e -St a ge O ut put Cur r ent LED Power Suppl y
2
3
OVER TEMPERATURE PROTECTION
SHORT PROTECTION
Shut down Re-power ON
SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
LCM-40DA series
I/P: 230 VAC
O/P:FULL LOAD
O.T.P. Active
Shut down Re-power ON
I/P: 295 VAC
O/P:FULL LOAD
Ta:25℃
NO DAMAGE
Constant Current Limiting
P
P
CONTROL FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
AUXILIARY POWER
12V @ 50mA for driving fan;
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
Tolerance +5%
2
DIP Switch Table
RESULT
VERDICT
12.085V/230V
P
LCM-40DA is a multiple-stage output current supply, selection of output current through DIP switch as
table below.
P
TEST:OK
3
TEMP.
SPECIFICATION:
COMPENSATION
LCM-40DA have the built-in temperature compensation function (T↑ , Io↓ ). By connecting a
temperature sensor ( NTC resistor) between the NTC +/terminal of LCM-40DA and the detecting point on the lighting system or the surrounding environment,
output current of LCM-40DA could be correspondingly changed to ensure the long life of LED.
1.LCM-40DA can still be operated well when the NTC resistor is not connected and the value of output
current will be the current level that you set
2.
NTC resistance
220K
Output Current
< 60℃, 100% of the rated current (corresponds to the setting current level)
< 70℃, 100% of the rated current (corresponds to the setting current level)
330K
P
< 80℃, 100% of the rated current (corresponds to the setting current level)
> 60℃, output current begin to reduce, details please refer to the curve.
470K
> 70℃, output current begin to reduce, details please refer to the curve.
> 80℃, output current begin to reduce, details please refer to the curve.
Notes:
1. MW does not offer the NTC resistor and all the data above are measured by using THINKING
TTC03 series.
2. If other brands of NTC resistor is applied,please check the temperature curve first.
3. Synchronization function of the power supply will be invalid when the "temperature compensation"
function is in use.
TEST CONDITION:I/P: 230 VAC
RESULT:OK
Model: LCM-40DA
Test Report
4 / 9
LCM-40DA series
40W Mul t i pl e -St a ge O ut put Cur r ent LED Power Suppl y
4
Dimming function
SPECIFICATION:
a.
PUSH dim(primary side)
.Maximum number of drivers up to 10 pcs.
.Maximum length of the cable, from push button to last driver is 15 meter.
.Factory setting at 100%.
.When the light is lower than 10% it will always dim up, or when the light output is higher than 90% it
will always dim down.
P
Warning: The pushbutton can only be connected in between the PUSH terminal of LCM-40DA and
AC/L (brown or black color). It would cause short circuit if it is connected to AC/N.
b. DALI interface(primary side)
.DALI protocol including 16 groups and 64 addresses.
.First step is fixed at 6% light output.
TEST CONDITION:I/P:230 VAC FULL LOAD
RESULT:OK
5
SYNCHRONIZATION
OPERATION
SPECIFICATION:
P
TEST CONDITION:I/P:230 VAC FULL LOAD
RESULT:OK
Model: LCM-40DA
Test Report
5 / 9
LCM-40DA series
40W Mul t i pl e -St a ge O ut put Cur r ent LED Power Suppl y
COMPONENT STRESS TEST
NO
1
2
3
4
5
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
Power Transistor
( D to S) or (C to E) Peak Voltage
U2 Rated
550V/5.2A
I/P:High-Line +3V = 298 V
O/P: (1)Full Load Turn on
(1)
438
V
(2)
432
V
(2) Output Short
(3)Full load continue
Ta:25℃
(3)
436
V
I/P:High-Line +3V = 298 V
O/P: (1)Full Load Turn on
(1)
122
V
(2)
9
V
(2)Output Short
(3)Full load continue
Ta:25℃
(3)
88.8
V
I/P:High-Line +3V = 298 V
O/P: (1)Full Load Turn on /Off
(1)
436
V
(2)
436
V
(2) Min load Turn on /Off
(3)Full Load /Min load
Change
Ta:25℃
(3)
440
V
I/P:High-Line +3V = 298 V
O/P: (1)Full Load Turn on /Off
(1)
13
V
(2)
12.8
V
(2) Min load Turn on /Off
(3)Full Load /Min load
Change
Ta:25℃
(3)
13
V
(1)
444
V
(2)
444
V
(3)
440
V
Diode Peak Voltage
Input Capacitor Voltage
Control IC Voltage Test
Power Transistor
( D to S) or (C to E) Peak Voltage
D100 Rated
300V/10A
C5 Rated:
22u/450V
U2 Rated
11.4V ~15V
Q1 Rated
7.3A/650V
I/P:High-Line +3V = 298 V
O/P: (1)Full Load Turn on
(2) Output Short
(3)Full load continue
Ta:25℃
VERDICT
Model: LCM-40DA
P
P
P
P
P
Test Report
6 / 9
LCM-40DA series
40W Mul t i pl e -St a ge O ut put Cur r ent LED Power Suppl y
 SAFETY & E.M.C. TEST
SAFETY TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
WITHSTAND VOLTAGE
I/P-O/P: 3.75 KVAC/min
I/P-O/P: 4 KVAC/min
I/P-O/P:
VERDICT
2.29
mA
P
Ta:25℃
NO DAMAGE
2
ISOLATION RESISTANCE
I/P-O/P:500VDC>100MΩ
I/P-O/P: 500 VDC
Ta:25℃/70%RH
I/P-O/P:
30
GΩ
P
NO DAMAGE
E.M.C TEST
NO
1
2
3
4
5
6
7
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
HARMONIC
EN61000-3-2
CLASS C
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
PASS
EN55015
CLASS B
I/P: 230 VAC (50HZ)
O/P:FULL/50% LOAD
Ta:25℃
PASS
Test by certified Lab
P
EN55015
CLASS B
I/P: 230 VAC (50HZ)
O/P:FULL LOAD
Ta:25℃
PASS
Test by certified Lab
P
EN61000-4-2
LIGHT INDUSTRY
AIR:8KV / Contact:4KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
EN61000-4-4
LIGHT INDUSTRY
INPUT: 1KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
IEC61000-4-5
LIGHT INDUSTRY
L-N :1KV
L,N-PE:2KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
CONDUCTION
RADIATION
E.S.D
E.F.T
SURGE
VERDICT
P
P
P
P
Test by certified Lab & Test Report Prepare
Model: LCM-40DA
Test Report
7 / 9
LCM-40DA series
40W Mul t i pl e -St a ge O ut put Cur r ent LED Power Suppl y
 RELIABILITY TEST
ENVIRONMENT TEST
NO
1
TEST ITEM
SPECIFICATION
TEMPERATURE RISE TEST
MODEL:LCM-40DA
TEST CONDITION
RESULT
VERDICT
DIP switch :1050mA
1. ROOM AMBIENT BURN-IN:14 HRS
I/P: 230VAC O/P: FULL LOAD Ta=24.4 ℃
2. HIGH AMBIENT BURN-IN: 52 HRS
I/P: 230VAC O/P: FULL LOAD Ta= 51.4 ℃
2
3
4
5
ROOM AMBIENT HIGH AMBIENT
Ta= 24.4 ℃
Ta= 51.4 ℃
NO
Position
1
70.9℃
90.7℃
2
C11
C12
69.5℃
90.7℃
3
RG1
65.2℃
92.1℃
4
LF2
61.5℃
81.0℃
5
BD1
70.1℃
90.0℃
6
L1
60.5℃
81.9℃
7
L2
69.2℃
88.8℃
8
C60
66.1℃
87.2℃
9
C5
68.8℃
93.8℃
10
C61
73.8℃
93.8℃
11
U2
74.3℃
107.2℃
12
D91
72.9℃
101.0℃
13
C36
60.9℃
91.4℃
14
C92
76.6℃
104.2℃
15
RTH2
70.8℃
96.8℃
16
T1
82.8℃
106.5℃
17
C203
68.5℃
88.3℃
18
C105
57.3℃
80.9℃
19
LF100
57.7℃
78.7℃
20
Q1
69.1℃
88.2℃
21
D8
72.2℃
89.2℃
22
D100
76.0℃
105.1℃
23
U905
66.9℃
84.4℃
I/P: 230VAC/100VAC
O/P: 100 ﹪LOAD
Ta= -35 ℃
TEST:OK
AFTER 12 HOURS
IN CHAMBER ON
CONTROL 50 ℃
I/P: 305 VAC
O/P:FULL LOAD
Ta= 50 ℃
TEST:OK
NO DAMAGE
HUMIDITY= 95 %R.H
LOW TEMPERATURE
TURN ON TEST
TURN ON AFTER 2 HOUR
HIGH HUMIDITY
HIGH TEMPERATURE
HIGH VOLTAGE
TURN ON TEST
TEMPERATURE
COEFFICIENT
+ 0.03 %/℃(0~50℃)
STORAGE TEMPERATURE TEST
1.
2.
3.
4.
5.
I/P: 230 VAC
O/P:FULL LOAD
Thermal shock Temperature: -45℃~ +90℃
Temperature change rate :25℃ / MIN
Dwell time low and high temperature : 30 MIN/EACH
Total test cycle:5 CYCLE
Input/Output condition: STATIC
P
P
P
+ 0.00009
%/℃(0~50℃)
P
OK
P
Model: LCM-40DA
Test Report
8 / 9
LCM-40DA series
40W Mul t i pl e -St a ge O ut put Cur r ent LED Power Suppl y
6
7
8
9
10
THERMAL SHOCK TEST
1.
2.
3.
4.
5.
VIBRATION TEST
Thermal shock Temperature: -35℃~ +50℃
Temperature change rate :25℃ / MIN
Dwell time low and high temperature : 30 MIN/EACH
Total test cycle:10 CYCLE
Input/Output condition: 230VAC/Full Load AC ON/OFF TEST
turn on 58sec;turn off 2sec
P
TEST:OK
1 Carton & 1 Set
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:10min/sweep cycle
(4) Acceleration:2G
(5) Test Time:60min in each axis (X.Y.Z)
(6) Ta:25℃
CAPACITOR
LIFE CYCLE
OK
P
LCM-40DA ;SUPPOSE C106
IS THE MOST CRITICAL COMPONENT
(1) I/P: 230VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME
(2) I/P: 230VAC O/P:FULL LOAD Ta= 50 ℃ LIFE TIME
(3) I/P: 230VAC O/P:75% LOAD Ta= 50 ℃ LIFE TIME
(4) I/P: 230VAC O/P:50% LOAD Ta= 50 ℃ LIFE TIME
MIL-HDBK-217F NOTICE S2 PARTS COUNT
TOTAL FAILURE RATE:193.6 KHRS
MTBF
DMTBF/Accelerated Life Test
(1)
(2)
(3)
(4)
798434HRS
109978HRS
208132HRS
313174HRS
P
P
Demonstration Mean Time Between Failure(Expected Life) :
30,000 hours @ Tcase 75℃
50,000 hours @ Tcase 65℃
P
SAMPLE
TESTER
REVIEW
APPROVAL
2012/11/29
RD SAMPLE
DANIEL GAO
SANFORD SU
VINCENT TSENG
2013/2/22
PRODUCT SAMPLE
W1301A31
DANIEL GAO
SANFORD SU
VINCENT TSENG
DATE
2009/08/04
Model: LCM-40DA
A50-F023
Test Report
9 / 9