MEANWELL HLG-240-54B

Test Report: HLG-240-54
240W Single Output Switching Power Supply
 DESIGN VERIFY TEST
Output Function Test
Input Function Test
Protection Function Test
Other Test
Component Stress Test
 SAFETY & E.M.C. TEST
Safety Test
E.M.C. Test
 RELIABILITY TEST
HLG-240 series
240W Single Output Switching Power Supply
DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
RIPPLE & NOISE
V1: 350 mVp-p (Max )
I/P: 230 VAC
V1:
VERDICT
56.4
mVp-p (Max )
O/P:FULL LOAD
P
Ta:25℃
2
OUTPUT VOLTAGE
CH1: 50 V~ 57 V
ADJUST RANGE
I/P: 230 VAC
48.76V~60.13V /230VAC
I/P:115VAC
48.76V~60.13 V/115VAC
O/P:MIN LOAD
P
Ta:25℃
3
CURRENT ADJ RANGE
2.23 A~ 4.45 A
I/P: 230 VAC
0.5A~4.881
A
P
O/P: CV=Vo-2V
Ta:25℃
4
CONSTANT CURRENT REGION
27 V~ 54V
I/P: 230 VAC
O/P=27V: 4.553
A
O/P:CV MODE
O/P=53V: 4.508
A
P
Ta:25℃
5
OUTPUT VOLTAGE
V1:
-1 % ~
1 % (Max)
TOLERANCE
I/P: 100 VAC /264VAC
V1: -0.07
%~ 0.07
%
P
O/P:FULL/ 0 % LOAD
Ta:25℃
6
LINE REGULATION
V1: - 0.5% ~
0.5 % (Max)
I/P:100 VAC ~264 VAC
V1:
0
%~
0
%
P
O/P:FULL LOAD
Ta:25℃
7
LOAD REGULATION
V1: - 0.5% ~
0.5 % (Max)
I/P: 230 VAC
V1: -0.06
%~
0.06
%
P
O/P:FULL ~MIN LOAD
Ta:25℃
8
SET UP TIME
230VAC/ 2500 ms (Max)
I/P: 230 VAC
230VAC/ 1747
ms
115VAC/ 2500 ms (Max)
I/P: 115 VAC
115 VAC/ 1798
ms
P
O/P:FULL LOAD
Ta:25℃
9
RISE TIME
230VAC/ 80 ms (Max)
I/P: 230 VAC
230VAC/
52
ms
115VAC/ 80 ms (Max)
I/P: 115 VAC
115 VAC/
52
ms
P
O/P:FULL LOAD
Ta:25℃
10
HOLD UP TIME
230VAC/ 15 ms (Typ)
I/P: 230 VAC
230VAC/
17.3
ms
115VAC/ 15 ms (Typ)
I/P: 115 VAC
115 VAC/
17
ms
P
O/P:FULL LOAD
Ta:25℃
11
OVER/UNDERSHOOT TEST
< +5%
I/P: 230 VAC
TEST:<
5
%
P
O/P:FULL LOAD
Ta:25℃
12
DYNAMIC LOAD
V1: 5400
mVp-p
I/P: 230 VAC
198mVp-p
O/P:(1)FULL /Min LOAD
P
90%DUTY/1KHZ
Ta:25℃
Model: HLG-240-54
Test Report
2 / 8
HLG-240 series
240W Single Output Switching Power Supply
13
DIMMER TEST
(B Type only)
SPEC:
*Reference resistance value for output current adjustment (Typical)
Resistance
value
Output
current
10K 20K 30K 40K 50K 60K 70K 80K 90K 100K 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% *1 ~ 10V dimming function for output current adjustment (Typical)
Dimming
value
Output
current
1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% *10V PWM signal for output current adjustment (Typical)
Duty value
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Output
current
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% TEST RESULT: I/P: 230 VAC ;Ta:25℃
1
Resistance
value
Output
current
%
2
Dimming
value
Output
current
%
3
Duty
value
Output
current
%
P
10K 20K 30K 40K 50K 60K 70K 80K 90K 100K 0.394A 0.868A 1.335A
1.947A
2.258A
2.717A
3.133A 3.586A 4.001A 4.401A 8.85% 19.51% 30.00%
43.75%
50.74%
61.06%
70.40% 80.58% 89.91% 98.90% 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 0.401A 0.873A 1.341A
1.797A
2.264A
2.738A
3.207A 3.653A 4.121A 4.455A 9.01% 19.62% 30.13%
40.38%
50.88%
61.53%
72.07% 82.09% 92.61% 100.11%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.440A 0.914A 1.371A
1.821A
2.266A
2.708A
3.146A 3.585A 4.024A 4.461A 9.89% 20.54% 30.81%
40.92%
50.92%
60.85%
70.70% 80.56% 90.43% 100.25%
Model: HLG-240-54
Test Report
3 / 8
HLG-240 series
240W Single Output Switching Power Supply
INPUT FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
INPUT VOLTAGE RANGE
90VAC~264 VAC
TEST CONDITION
RESULT
I/P:TESTING
VERDICT
59V~264V
O/P:FULL LOAD
Ta:25℃
I/P:
TEST: OK
(1)LOW-LINE-3V=87 V
P
(2)HIGH-LINE=264 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10MIN
( AC POWER ON/OFF NO DAMAGE )
2
INPUT FREQUENCY RANGE
47HZ ~63 HZ
I/P: 100 VAC ~264VAC
NO DAMAGE OSC
O/P:FULL~MIN LOAD
OK
P
Ta:25℃
3
4
POWER FACTOR
0.95/ 230 VAC FULL LOAD (TYP)
I/P: 230 VAC
PF=0.953 /230V/100%LOAD
0.98/ 115 VAC FULL LOAD (TYP)
I/P: 115 VAC
PF=1
0.9/ 230 VAC 65% LOAD (TYP)
O/P:FULL LOAD / 65% LOAD
PF=0.917 /230V/65%LOAD
0.9/ 115 VAC 65%LOAD (TYP)
Ta:25℃
PF=1
EFFICIENCY
94 % (TYP)
/115V/100%LOAD
P
/115V/65%LOAD
I/P: 230 VAC
94.14
%
P
O/P:FULL LOAD
Ta:25℃
5
INPUT CURRENT
230 V/ 2
A (Typ)
I/P: 230 VAC
I=
1.15
A/ 230VAC
115 V/ 4
A (Typ)
I/P: 115 VAC
I=
2.29
A/ 115VAC
I=
66
P
O/P:FULL LOAD
Ta:25℃
6
INRUSH CURRENT
230 V/ 75A (Typ)
I/P: 230 VAC
COLD START
O/P:FULL LOAD
A/ 230VAC
P
Ta:25℃
PROTECTION FUNCTION TEST
NO
1
TEST ITEM
OVER LOAD PROTECTION
SPECIFICATION
95 %~108 %
TEST CONDITION
RESULT
VERDICT
I/P: 264 VAC
101
%/264VAC
I/P: 230 VAC
101
%/ 230VAC
I/P: 100 VAC
101
%//100VAC
O/P:TESTING
P
Constant Current Limiting
Ta:25℃
2
OVER VOLTAGE PROTECTION
V1: 59 V~ 65V
I/P: 264 VAC
64.3 V/264VAC
I/P: 230 VAC
64.3 V/ 230VAC
I/P: 90 VAC
O/P:MIN LOAD
64.3V/ 90VAC
P
Shunt down Re- power ON
Ta:25℃
3
OVER TEMPERATURE PROTECTION
SPEC:
I/P: 230 VAC
TSW1: 105±5℃ O.T.P.
O/P:FULL LOAD
NO DAMAGE
O.T.P. Active
Shut down o/p volotage,recovers
automatically
after
temperature
P
goes down
4
SHORT PROTECTION
SHORT EVERY OUTPUT
I/P: 264VAC
NO DAMAGE
1 HOUR NO DAMAGE
O/P: FULL LOAD
Hiccup Mode
P
Ta:25℃
Model: HLG-240-54
Test Report
4 / 8
HLG-240 series
240W Single Output Switching Power Supply
COMPONENT STRESS TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
Power Transistor
Q3 Rated
I/P:High-Line +3V = 267 V
(1)
464
V
( D to S) or (C to E) Peak Voltage
IRFB20N50K 20A/ 500V
(2)
442
V
(3)
460
V
I/P:High-Line +3V = 267 V
(1)
123
O/P: (1)Full Load Turn on
(2)
123
V
(3)
123
V
O/P: (1)Full Load Turn on
(2) Output Short
VERDICT
P
(3)Fulll load continue
Ta:25℃
2
Diode Peak Voltage
Q101
Rated
YA868C15RSC 30A/150V
(2)Output Short
V
(3)Fulll load continue
Ta:25℃
Rated
I/P:High-Line +3V = 267 V
(1)
124
YA868C15RSC 30A/150V
O/P: (1)Full Load Turn on
(2)
27
V
(3)
123
V
Q102
(2)Output Short
P
V
(3)Fulll load continue
Ta:25℃
3
Input Capacitor Voltage
C5 Rated:
I/P:High-Line +3V = 267 V
(1)
399
NCC:
150μ/420 V/105℃
O/P: (1)Full Load Turn on /Off
(2)
416
V
(2) Min load Turn on /Off
(3)
416
V
V
P
(3)Full Load /Min load
Change
Ta:25℃
4
Control IC Voltage Test
U 70 Rated
L6599AD : 8.85V~16 V
I/P:High-Line +3V = 267 V
(1)
13.13
V
O/P: (1)Full Load Turn on /Off
(2)
13.11
V
(2) Min load Turn on /Off
(3)
13.13
V
P
(3)Full Load /Min load
Change
Ta:25℃
5
P.F.C Transistor
Q1 Rated
I/P:High-Line +3V = 267 V
(1)
478
V
( D to S) or (C to E) Peak Voltage
STW25NM50N 22A/500V
O/P: (1)Full Load Turn on
(2)
462
V
(3)
454
V
(2)Output Short
P
(3)Fulll load continue
Ta:25℃
Model: HLG-240-54
Test Report
5 / 8
HLG-240 series
240W Single Output Switching Power Supply
SAFETY & EMC TEST
SAFETY TEST
NO
1
2
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
WITHSTAND VOLTAGE
IEC60950-1
I/P-O/P: 4 KVAC/min
I/P-O/P: 4.90
I/P-O/P: 3.75KVAC/min<10mA
I/P-FG: 2.256KVAC/min
I/P-FG:
4.05
mA
I/P-FG:1.88 KVAC/min<10mA
O/P-FG: 1.8 KVAC/min
O/P-FG: 5.15
mA
O/P-FG:1.5KVAC/min<10mA
Ta:25℃
NO DAMAGE
I/P-O/P:500VDC>100MΩ
I/P-O/P: 500
VDC
I/P-O/P: 27.2
I/P-FG: 500VDC>100MΩ
I/P-FG:
500
VDC
I/P-FG:
O/P-FG:500VDC>100MΩ
O/P-FG: 500
VDC
O/P-FG: 30
ISOLATION RESISTANCE
Ta:25℃
3
GROUNDING CONTINUITY
IEC60950-1
OR TRACE <
4
LEAKAGE CURRENT
P
GΩ
16.8
GΩ
P
GΩ
NO DAMAGE
40A / 2min
FG(PE) TO CHASSIS
VERDICT
mA
13
mΩ
Ta:25℃
P
100 mΩ
IEC60950-1
I/P: 264 VAC
L-FG:
0.36
mA
< 0.75 mA / 240VAC
O/P:Min LOAD
N-FG:
0.36
mA
P
Ta:25℃
5
APPROVAL
TUV: Certificate NO :R50171244
P
UL: File NO :E127738
E.M.C TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
HARMONIC
EN61000-3-2
I/P: 240VAC/50HZ
PASS
CLASS A
LOAD:LED/ELECTRONIC LOAD
CLASS C
O/P:100%/50% LOAD
VERDICT
P
Ta:25℃
2
CONDUCTION
EN55022 EN55015
I/P: 230 VAC (50HZ)
PASS
CLASS B
O/P:FULL/50% LOAD
Test by certified Lab
P
Ta:25℃
3
4
5
RADIATION
E.S.D
E.F.T
EN55022 EN55015
I/P: 230 VAC (50HZ)
CLASS B
O/P:FULL LOAD
SURGE
P
Ta:25℃
Test by certified Lab
EN61000-4-2
I/P: 230 VAC/50HZ
CRITERIA A
LIGHT INDUSTRY
O/P:FULL LOAD
AIR:8KV / Contact:4KV
Ta:25℃
EN61000-4-4
I/P: 230 VAC/50HZ
LIGHT INDUSTRY
O/P:FULL LOAD
INPUT: 2KV
6
PASS
CRITERIA A
P
Ta:25℃
IEC61000-4-5
I/P: 230 VAC/50HZ
LIGHT INDUSTRY
O/P:FULL LOAD
L-N :2KV
P
CRITERIA A
P
Ta:25℃
L,N-PE:4KV
Model: HLG-240-54
Test Report
6 / 8
HLG-240 series
240W Single Output Switching Power Supply
Reliability Test
NO
1
TEST ITEM
SPECIFICATION
TEMPERATURE RISE TEST
MODEL:HLG-240H-24
TEST CONDITION
RESULT
VERDICT
1. ROOM AMBIENT BURN-IN:1.5 HRS
I/P: 230VAC O/P: FULL LOAD Ta= 26.5
℃
2. HIGH AMBIENT BURN-IN: 12 HRS
I/P: 230VAC O/P: FULL LOAD Ta= 61.7
OVER LOAD BURN-IN TEST
ROOM AMBIENT HIGH AMBIENT
Ta= 26.5 ℃
Ta= 61.7 ℃
64.0℃
91.1℃
NO
Position
P/N
1
LF1
C1
684/275VAC 20% P=15 R.46
61.3℃
89.3℃
91.2℃
2
2
℃
TR688-R4
3
LF2
TR827-R1 R-16x12x8C
63.4℃
4
BD1
10A/800V SILICON US10KB80R
64.0℃
92.7℃
5
L2
TR892 CS-17212 142u GS220
62.7℃
90.9℃
6
L1
DT TF1940 QP-3325 CLG-240
61.5℃
89.9℃
7
Q1
SPW20N60C3 20.7A/600V TO247
64.7℃
93.2℃
8
U1
NCP1605DR2G SOIC-16
61.5℃
90.2℃
9
TSW1
ST-22W-R0 105℃ 60mm
64.1℃
92.7℃
10
Q3
STF21NM60N 17A/600V TO220 FP
65.1℃
93.3℃
106.6℃
98.3℃
11
T1
TF1944 LP-3925 CLG-240-24 B
79.0℃
12
Q101
IRFB3607PBF 80A/75V
69.6℃
13
C102
1000u/35V UL10Kh 12.5*20 ZLH
66.5℃
94.9℃
14
LF101
TR847-R2 T14x8x7(A07)
71.8℃
100.1℃
NO DAMAGE
I/P: 230 VAC
1 HOUR ( MIN )
O/P:O/P SHORT TEST
P
TEST:OK
P
Ta:25℃
3
LOW TEMPERATURE
TURN ON AFTER
2 HOUR
I/P: 230 VAC/100VAC
TEST:OK
O/P:CV=23V
TURN ON TEST
P
Ta= -35 ℃
4
HIGH HUMIDITY
HIGH TEMPERATURE
5
AFTER 12
HOURS
IN CHAMBER ON
CONTROL 60 ℃
Ta= 61.7 ℃
TURN ON TEST
NO DAMAGE
HUMIDITY=
TEMPERATURE
+ 0.03 %(0~50℃)
STORAGE TEMPERATURE TEST
TEST:OK
O/P:CV=23V
HIGH VOLTAGE
P
95 %R.H
I/P: 230 VAC
+ 0.003
%(0~50℃)
O/P:FULL LOAD
COEFFICIENT
6
I/P: 264 VAC
1. Thermal shock Temperature: -45℃~ +90℃
P
OK
2. Temperature change rate :25℃ / MIN
3. Dwell time low and high temperature : 30 MIN/EACH
P
4. Total test cycle:5 CYCLE
5. Input/Output condition: STATIC
7
THERMAL SHOCK TEST
1. Thermal shock Temperature: -35℃~ +65℃
OK
2. Temperature change rate :25℃ / MIN
3. Dwell time low and high temperature : 30 MIN/EACH
P
4. Total test cycle:10 CYCLE
5. Input/Output condition: 230VAC/Full Load
Model: HLG-240-54
Test Report
7 / 8
HLG-240 series
240W Single Output Switching Power Supply
8
VIBRATION TEST
TEST:OK
1 Carton & 1 Set
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:12min/sweep cycle
P
(4) Acceleration:5G
(5) Test Time:72min in each axis (X.Y.Z)
(6) Ta:25℃
9
CAPACITOR
LIFE CYCLE
10
HLG-240H-24:SUPPOSE C102 IS THE MOST CRITICAL COMPONENT
(1) I/P: 230VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME
(1)
196640 HRS
(2) I/P: 230VAC
(2)
27898.3 HRS
O/P:FULL LOAD Ta= 60 ℃
LIFE TIME
P
(3) 54198.9 HRS
(3) I/P: 230VAC O/P:75% LOAD
Ta= 60 ℃ LIFE TIME
MIL-HDBK-217F NOTICES2 PARTS COUNT Mean Time Between Failure: 207.9K HRS
MTBF
P
11
DMTBF/Accelerated Life Test
DATE
2009/7/31
2009/9/29
2009/12/2
Demonstration Mean Time Between Failure(Expected Life) : 50,000 hours @ Tcase 70℃
P
SAMPLE
TEST RESULT
TESTER
APPROVAL
RD SAMPLE
PASS
SANFORD SU
VINCENT TSENG
PASS
SANFORD SU
VINCENT TSENG
PASS
SANFORD SU
VINCENT TSENG
PRODUCT SAMPLE
W0907E29
PRODUCT SAMPLE
W0910C36
2003/12/12
Model: HLG-240-54
A50-F023
Test Report
8 / 8