75W Single Output Industrial DIN RAIL
EDR-75
series
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
www.tuv.com
ID 2000000000
■ 
‧ 
‧ 

‧ 
‧ 
‧ 
‧ 
‧ 
‧ 
■ 
‧
‧
‧
‧
■ 


                                                              


℃℃




■ 
    



File Name:EDR-75-SPEC 2014-08-10
EDR-75
75W Single Output Industrial DIN RAIL
series
SPECIFICATION
MODEL
EDR-75-12
EDR-75-24
EDR-75-48
DC VOLTAGE
12V
24V
48V
RATED CURRENT
6.3A
3.2A
1.6A
CURRENT RANGE
0 ~ 6.3A
0 ~ 3.2A
0 ~ 1.6A
RATED POWER
OUTPUT
75.6W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
12 ~ 14V
76.8W
76.8W
120mVp-p
150mVp-p
24 ~ 28V
48 ~ 55V
VOLTAGE TOLERANCE Note.3 ±2.0%
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±1.0%
±1.0%
±1.0%
SETUP, RISE TIME
1200ms, 60ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
60ms/230VAC
Note.6
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
85.5%
1.45A/115VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVER VOLTAGE
20A/115VAC
87.5%
88.5%
0.9A/230VAC
35A/230VAC
105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
29 ~ 33V
14 ~ 17V
56 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-20 ~ +60℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY STANDARDS
UL508, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 4)
EMC EMISSION
EMC IMMUNITY
NOTE
[DC input operation possible by connecting AC/L(+), AC/N(-)]
OVER TEMPERATURE
ENVIRONMENT STORAGE TEMP., HUMIDITY
OTHERS
12ms/115VAC at full load
127 ~ 370VDC
47 ~ 63Hz
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
OVERLOAD
PROTECTION
90 ~ 264VAC
2000ms, 60ms/115VAC at full load
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 (CISPR22) Class A, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
506.6K hrs min.
DIMENSION
32*125.2*102mm (W*H*D)
PACKING
0.51Kg; 28pcs/15.3Kg/1.22CUFT
MIL-HDBK-217F (25℃)
℃







File Name:EDR-75-SPEC 2014-08-10
EDR-75
75W Single Output Industrial DIN RAIL
series
Block Diagram
fosc : 85KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
O.C.P.
O.L.P.
FG
DETECTION
CIRCUIT
PWM
CONTROL
O.T.P.
O.V.P.
Derating Curve
Static Characteristics
230VAC
100
100
24V,48V(230VAC)
90
80
80
12V(230VAC)
115VAC
70
12V,24V,48V(115VAC)
50
LOAD (%)
LOAD (%)
60
40
20
-20
-10
0
10
20
30
40 45 50
AMBIENT TEMPERATURE (℃)
60
70 (VERTICAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:EDR-75-SPEC 2014-08-10
EDR-75
75W Single Output Industrial DIN RAIL
series
Mechanical Specification
Case No.221B
Unit:mm
Top View
102
35
39
1234
TB2
125.2
(12V,24V only)
DC OK
+V ADJ.
(48V only)
TB1
123
Side View
Front View
Side View
Terminal Pin No. Assignment (TB1)
Pin No.
1
2
3
Assignment
FG
AC/N or DC AC/L or DC +
Terminal Pin No. Assignment (TB2)
Pin No.
1,2
3,4
Assignment
DC OUTPUT -V
DC OUTPUT+V
Bottom View
Installation Instruction
35
This series fits DIN rail TS35/7.5 or TS35/15.
For installation details, please refer to the USER MANUAL on
http://www.meanwell.com/search/EDR-75/EDR_manual.pdf
ADMISSIBLE DIN rail:TS35/7.5 OR TS35/15
(For reference only. Not included with unit.)
Back View
File Name:EDR-75-SPEC 2014-08-10