SPEC - Meanwell

LPC-100
100W Single Output LED Power Supply
series
■ Features :
Constant current design
Universal AC input/full rauge
Withstand 300VAC surge input for 5 seconds
High efficiency up to 90%
Protections: Short circuit / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level (Note.6)
Fully isolated plastic case
ClassⅡ power unit, no FG
Suitable for LED lighting and moving sign applications( Note. 7)
100% full load burn- in test
Low cost, high reliability
2 years warranty (Note.4)
IP67
SPECIFICATION
LPC-100-350
LPC-100-500
LPC-100-700
LPC-100-1050
LPC-100-1400
LPC-100-1750
LPC-100-2100
RATED CURRENT
350mA
500mA
700mA
1050mA
1400mA
1750mA
2100mA
CURRENT ACCURACY
±5.0%
100 ~ 200V
72 ~ 143V
48 ~ 96V
36 ~ 72V
29 ~ 58V
24 ~ 48V
100W
100.1W
100.8W
100.8W
101.5W
100.8W
1.5Vp-p
1Vp-p
1Vp-p
1Vp-p
1Vp-p
1Vp-p
MODEL
CONSTANT CURRENT REGION Note.5 143 ~ 286V
OUTPUT
RATED POWER
100.1W
RIPPLE CURRENT
±5%
RIPPLE & NOISE
1.5Vp-p
LINE REGULATION
±1%
VOLTAGE TOLERANCE
±1.5%
SETUP, RISE TIME
1000ms, 80ms / 230VAC
HOLD UP TIME (Typ.)
16ms/230VAC
VOLTAGE RANGE
Note.2 90 ~ 264VAC
FREQUENCY RANGE
INPUT
90%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.2 A / 115VAC
<0.25mA / 240VAC
OVER VOLTAGE
220 ~ 240V
108 ~ 120V
315 ~ 345V
160 ~ 172V
80 ~ 97V
Protection type : Shut down and latch off o/p voltage re-power on to recovery
WORKING TEMP.
-25 ~ +50℃ (Refer to "Derating Curve")
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
IP67 approved,Design refer to TUV EN60950-1
I/P-O/P:3KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022(CISPR22) Class B; EN61000-3-2 Class A(≦80% load); EN61000-3-3
EMC EMISSION
DIMENSION
58 ~ 68V
10 ~ 95% RH non-condensing
WITHSTAND VOLTAGE
PACKING
NOTE
65 ~ 80V
SAFETY STANDARDS
EMC IMMUNITY
MTBF
OTHERS
COLD START 75A(twidth=980μs measured at 50% Ipeak) at 230VAC
Hiccup mode, recovers automatically after fault condition is removed
VIBRATION
89%
1 units (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
EMC
89.5%
1.2A / 230VAC
SHORT CIRCUIT
PROTECTION
SAFETY &
127VDC ~ 370VDC
47 ~ 63Hz
EFFICIENCY (Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2000ms,80ms/115VAC at full load
10ms/115vac at full load
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level , criteria A
511Khrs min. MIL-HDBK-217F (25℃)
190*52*37mm (L*W*H)
0.61Kg;20pcs/13.2Kg/0.55CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Derating may be needed under low input voltages. Please check the static characteristics for more details.
3. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
4. Refer to warranty statement.
5. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6.Suitable for indoor use or outdoor use without direct sunlight exposure, please avoid immerse in the water over 30minutes.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:LPC-100-SPEC 2015-05-28
LPC-100
100W Single Output LED Power Supply
Mechanical Specification
Case No. LPC-100
190
300±10
series
Unit:mm
300±10
3.5
3.5
T case
+V(Red)
-V(Black)
96
17
UL 1015 18AWG
3.5
52
AC/L(Brown)
AC/N(Blue)
UL 1015 18AWG
3.5
2.5
37
※ T case: Max. Case Temperature.
Recommend Mounting Direction
Block Diagram
fosc : 67KHz
65KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
O.L.P.
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-25
-15
0
15
30
40
50
AMBIENT TEMPERATURE (℃)
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:LPC-100-SPEC 2015-05-28