RPD-60 series

RPD-60
60W Dual Output Medical Type
series
■ Features :
4"×2" miniature size
Universal AC input/Full range
Low leakage current <100μ A
Protections: Short circuit / Over load / Over voltage
Cooling by free air convection
Medical safety approved (2 x MOPP between primary to secondary)
UL60950-1/IEC60950-1/EN60950-1 ITE safety approved
Fixed switch frequency at 100KHz
Suitable for BF application with appropriate system consideration
3 years warranty
..
SPECIFICATION
MODEL
OUTPUT
INPUT
RPD-60B
RPD-60A
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
5A
2A
3.5A
1.5A
CURRENT RANGE
0.5 ~ 5.5A
0.1 ~ 2.2A
0.5 ~ 3.85A
0.1 ~ 1.65A
RATED POWER
49W
PEAK LOAD(10sec.)
53.5W
Note.4 53.9W
58.85W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
80mVp-p
100mVp-p
VOLTAGE TOLERANCE Note.3 +3,-2%
±6.0%
+3,-2%
+8,-4%
LINE REGULATION
±0.5%
±1.0%
±0.5%
±1.0%
LOAD REGULATION
±1.5%
±2.0%
±1.5%
±2.0%
SETUP, RISE TIME
300ms, 15ms/230VAC
HOLD UP TIME (Typ.)
70ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
78%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.1A/115VAC
0.7 A/230VAC
COLD START 60A/230VAC
30A/115VAC
LEAKAGE CURRENT
300ms, 15ms/115VAC at full load
14ms/115VAC at full load
127 ~ 370VDC
82%
Note.8 Earth leakage current < 150 μA/264VAC , Touch current < 100μ A/264VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
115 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +65℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 45℃)
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
SAFETY & ISOLATION LEVEL
WITHSTAND VOLTAGE
EMC
Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
(Note 5)
OTHERS
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A
MTBF
677.8K hrs min. MIL-HDBK-217F (25℃)
101.6*50.8*29mm (L*W*H)
0.15Kg; 96pcs/15.4Kg/0.89CUFT
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Heat Sink HS1,HS2 can not be shorted.
8. Touch current was measured from primary input to DC output.
File Name:RPD-60-SPEC 2015-07-17
RPD-60
60W Dual Output Medical Type
Mechanical Specification
Unit:mm
101.6
3.175
95.25
50.8
44.45
FS1
CN1
series
3.175
AC FUSE
T2.5/250V
3
2
1
HS2
1
2
3
4
5
6
FS2
AC FUSE
T2.5/250V
CN2
HS1
M1
M2
3 max.
29
4-ψ3.3
DC Output Connector (CN2) : JST B6P-VH or equivalent
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1
2
3
Assignment
AC/N
No Pin
AC/L
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Pin No.
1,2
3,4
5
6
: Grounding Required
Assignment
V1
COM
V2
NC
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
1.HS1,HS2 cannot be shorted.
2.M1 is safety ground. For better EMC performance,
Please secure an electrical connection between
M1,M2 and chassis grounding.
Block Diagram
fosc : 100KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
RECTIFIERS
&
FILTER
V2
RECTIFIERS
&
FILTER
+V1
COM
DETECTION
CIRCUIT
FG
O.L.P.
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-20
0
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60 65 70 (HORIZONTAL)
60
50
40
90
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:RPD-60-SPEC 2015-07-17