DRA-40 series

DRA-40
40W Single Output Switching Power Supply
LPS
■ Features
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Can be installed on DIN rail TS-35/7.5 or 15
Output Voltage adjustable through internal potentiometer
Output Current adjustable through external 1~10Vdc, PWM
series
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
www.tuv.com
ID 2000000000
■ Applications
Machine vision inspection system
Plant cultivation system
signal or resistance
Cooling by free air convection
Pass LPS
LED indicator for power on
100% full load burn-in test
3 years warranty
■ Description
DRA-40 is one 40W AC/DC DIN rail power supply, featuring the adjustable output current. Users are
able to easily change the constant output current level, via 1~10Vdc, PWM signal or resistance.
DRA-40 can be mounted on DIN rail TS-35/7.5 or 15; in addition, the width of the unit is only 40mm that
it is well suited for the installation in a limited spacing. DRA-40 accepts the universal AC input between
90VAC and 264VAC; the efficiency is up to 87% that the entire series can operate, under free air convection,
from -30 ℃ through 70 ℃ .
■ Model Encoding
DRA - 40 - 12
Output voltage
Output wattage
Series name
File Name:DRA-40-SPEC 2015-06-11
DRA-40
40W Single Output Switching Power Supply
series
SPECIFICATION
MODEL
OUTPUT
DRA-40-12
DRA-40-24
DC VOLTAGE
12V
24V
CONSTANT CURRENT REGION
3~12V
3~24V
RATED CURRENT
3.34A
1.7A
CURRENT RANGE
0 ~ 3.34A
0 ~ 1.7A
RATED POWER
40.08W
40.8W
RIPPLE & NOISE (max.) Note.2 120mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
24 ~ 30V
12 ~ 15V
VOLTAGE TOLERANCE Note.3 ±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
LOAD REGULATION
±0.5%
±0.5%
SETUP, RISE TIME Note.4 400ms, 90ms/230VAC
INPUT
HOLD UP TIME (Typ.)
50ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
85%
AC CURRENT (Typ.)
0.8A/115VAC
INRUSH CURRENT (Typ.)
OVERLOAD
PROTECTION
OVER VOLTAGE
800ms, 90ms/115VAC at full load
10ms/115VAC at full load
127 ~ 370VDC
[DC input operation possible by connecting AC/L(+), AC/N(-)]
87%
0.6A/230VAC
COLD START 30A/115VAC
60A/230VAC
95 ~ 108% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
14.49 ~ 18.63V
28.98 ~ 37.26V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 55℃) on output
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
(Note 5)
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A
439.3K hrs min.
MIL-HDBK-217F (25℃)
40*90*100mm (W*H*D)
0.3Kg; 42pcs/13.6Kg/0.82CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power
supplies.” (as available on http://www.meanwell.com)
6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded
permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
File Name:DRA-40-SPEC 2015-06-11
DRA-40
40W Single Output Switching Power Supply
series
Block Diagram
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
DIM+
DIM-
O.C.P.
DETECTION
CIRCUIT
FG
CONTROL
O.L.P.
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
LOAD (%)
LOAD (%)
60
40
20
-30
-20
0
15
30
40
50 55 60
60
50
40
70 (VERTICAL)
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
AMBIENT TEMPERATURE (℃)
OUTPUT CURRENT ADJUSTMENT OPERATION
※ Built-in 3 in 1 current adjustment function . Output constant current level can be adjusted by applying 1 ~ 10Vdc, 10V PWM
signal or resistance between DIM+ and DIM-.
※ Please DO NOT connect "DIM-" to "-V".
※ Reference resistance value for output current adjustment (Typical)
Single Power supply
Resistance
Multiple Power supplies
value
(N=Power supply quantity for simultaneous
current adjustment control)
Percentage of rated current
10KΩ
20KΩ 30KΩ 40KΩ 50KΩ
60KΩ
70KΩ 80KΩ 90KΩ 100KΩ
10KΩ/N 20KΩ/N 30KΩ/N 40KΩ/N 50KΩ/N 60KΩ/N 70KΩ/N 80KΩ/N 90KΩ/N 100KΩ/N
10%
OPEN
-----
20%
30%
40%
50%
60%
70%
80%
90%
100%
102%~108%
※ 1 ~ 10Vdc for output current adjustment (Typical)
Applied Source
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
102%~108%
※ 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz
Duty value
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
102%~108%
File Name:DRA-40-SPEC 2015-06-11
DRA-40
40W Single Output Switching Power Supply
series
a the output
※Using the current adjustment function can not adjust the output current to 0A. Please refer to the connection method below todjust
current to 0A.
10K~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
LOAD
+V +V -V -V
DIMDIM+
Adjuster
DC OK
Switch
+
+V ADJ
Relay
N
L
L
FG N
DRIVING METHODS OF APPLICATIONS
The power supply may either work in "constant voltage mode or constant current mode"
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Rated
output
voltage
(B)
Constant
Current area
(A) Constant
Voltage area
Should there be any compatibility issues, please contact MEAN WELL.
Vo(v)
3V
(C)
Hiccup
Protection
50
100
Io (%)
File Name:DRA-40-SPEC 2015-06-11
40W Single Output Switching Power Supply
DRA-40
Mechanical Specification
Case No.962A
5
5
5
5
DIM+
DIM-
+V +V -V -V
Unit:mm
100
40
5
series
DC OK
90
+
+V ADJ
N
L
7.5 7.5
Installation Instruction
35
This series fits DIN rail TS35/7.5 or TS35/15.
For installation details, please refer to the USER MANUAL on
http://www.meanwell.com/search/DRA-40/DRA_manual.pdf
(This diagram is for reference. The rail is not included with unit.)
Back View
File Name:DRA-40-SPEC 2014-10-22