MEANWELL LPF-25D-48

LPF-25D
25W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 305VAC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
Cooling by free air convection
Fully isolated plastic case
Fully encapsulated with IP67 level (Note.6)
Class power unit, no FG
Class 2 power unit
Built-in 3 in 1 dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
110
F
M
M
IP67
SELV
( for 48V,54V only)
( except for 48V,54V )
SPECIFICATION
LPF-25D-12 LPF-25D-15 LPF-25D-20 LPF-25D-24 LPF-25D-30 LPF-25D-36 LPF-25D-42 LPF-25D-48 LPF-25D-54
MODEL
12V
DC VOLTAGE
CONSTANT CURRENT REGION Note.4 6 ~12V
OUTPUT
20V
24V
30V
36V
42V
48V
54V
7.5 ~ 15V
10 ~ 20V
12 ~ 24V
18 ~ 36V
21 ~ 42V
24 ~ 48V
27 ~ 54V
0.7A
0.6A
0.53A
0.47A
RATED CURRENT
2.1A
1.67A
1.25A
1.05A
15 ~ 30V
0.84A
RATED POWER
25.2W
25.05W
25W
25.2W
25.2W
25.2W
25.2W
25.44W
25.38W
150mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
250mVp-p
250mVp-p
350mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE TOLERANCE Note.3
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
Note.7 1500ms, 80ms / 115VAC at full load
16ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
15V
Note.5 90 ~ 305VAC
1500ms, 80ms / 230VAC
230VAC /115VAC
127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
84%
85%
84%
0.4A / 115VAC
0.2A / 230VAC
COLD START 50A/230VAC
AC CURRENT
INRUSH CURRENT (Typ.)
85.5%
85.5%
85.5%
86%
86%
54 ~ 63V
59 ~ 66V
<0.75mA / 240VAC
LEAKAGE CURRENT
OVER CURRENT
85.5%
Note.4
PROTECTION SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
34 ~ 40V
15 ~ 18V
17.5 ~ 21V 23 ~ 27V
28 ~ 35V
41 ~ 49V
46 ~ 54V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
95J Ó 5J( TSW1) Detect on U2
Protection type : Shut down o/p voltage, recover automatically after temperature goes down
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.6 UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V),EN61347-1, EN61347-2-13 independent, IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015; EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547,light industry level(surge 2KV), criteria A
418.5Khrs min. MIL-HDBK-217F (25
148*40*32mm (L*W*H)
0.36Kg; 40pcs/ 15.4Kg/1.02CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight explosure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:LPF-25D-SPEC 2011-12-21
LPF-25D
25W Single Output Switching Power Supply
Mechanical Specification
Case No. :LPF-16A
148
300 20
series
Unit:mm
300 20
SJTW 18AWG*2C
3.6
SVT 18AWG*4C
40
3.6
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
60
13
3.5
AC/N(Blue)
AC/L(Brown)
3.5
3.5
3.5
32
T case: Max. Case Temperature.
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
DIM+
DIM-
O.L.P.
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
LOAD (%)
LOAD (%)
60
40
20
-40
-30
-15
0
15
30
AMBIENT TEMPERATURE (
50
)
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
File Name:LPF-25D-SPEC 2011-12-21
25W Single Output Switching Power Supply
LPF-25D
series
Power Factor Characteristic
Constant Current Mode
PF
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
.9 9
.9 8
.9 7
.9 6
.9 5
.9 4
.9 3
.9 2
.9 1
0 .9
.8 9
.8 8
.8 7
.8 6
.8 5
.8 4
277VAC
230VAC
115VAC
50%
60%
70%
80%
90%
100%
(25W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
LPF-25D series possess superior working efficiency that up to 86% can be reached in field applications.
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
72
71
70
277VAC
230VAC
115VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
(A)
Constant
Current area
Vo(%)
100
50
(max.)
(B)
Hiccup
Protection
50
95
Io(%)
Typical LED power supply I-V curve
File Name:LPF-25D-SPEC 2011-12-21
LPF-25D
25W Single Output Switching Power Supply
series
DIMMING OPERATION
AC/N(Blue)
AC/L(Brown)
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
LPF-25D
Output constant current level can be adjusted through output cable by 1 ~ 10Vdc, 10V PWM signal or resistance between DIM+ and DIM-.
Reference resistance value for output current adjustment (Typical)
Resistance value
Output current
10K
10%
20K
20%
30K
40K
30%
40%
60K
50K
50%
70K
80K
90K
100K
60%
70%
80%
90%
100%
OPEN
95%~108%
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
Output current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
95%~108%
10V PWM signal for output current adjustment (Typical): Frequency range :100~3KHz
Duty value
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Output current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
95%~108%
Dimming connection diagram for turning the lighting fixture ON/OFF :
N
L
Switch
Relay
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Brown
Blue
AC/L
LPF-25D
AC/N
DIM+
DIMV(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output cable by connecting a resistor or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:LPF-25D-SPEC 2011-12-21