MEANWELL LPF-90D

LPF-90D
90W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 90.5%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Fully encapsulated with IP67 level (Note.6)
Class
power unit, no FG
Built-in 3 in 1 dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
110
F
M
M
SELV
IP67
( except for 48V,54V )
SPECIFICATION
MODEL
DC VOLTAGE
LPF-90D-15
LPF-90D-20
LPF-90D-24
LPF-90D-30
LPF-90D-36
15V
20V
24V
30V
12 ~ 20V
14.4 ~ 24V
CONSTANT CURRENT REGION Note.4 9 ~ 15V
OUTPUT
48V
54V
25.2 ~ 42V
28.8 ~ 48V
32.4 ~ 54V
4.5A
3.75A
2.5A
2.15A
1.88A
1.67A
75W
90W
90W
90W
90W
90.3W
90.24W
90.18W
150mVp-p
150mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE TOLERANCE Note.3
4.0%
4.0%
4.0%
4.0%
LINE REGULATION
0.5%
0.5%
0.5%
LOAD REGULATION
1.5%
1.0%
0.5%
Note.7 2000ms, 200ms at 95% load
16ms/230VAC
Note.5 90 ~ 305VAC
4.0%
0.5%
4.0%
4.0%
0.5%
4.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
230VAC / 115VAC
16ms/115VAC at full load
127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.96/230VAC, PF>0.95/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
89.5%
89%
90%
0.95A / 115VAC
0.5A / 230VAC
COLD START 70A/230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
Note.4
PROTECTION OVER VOLTAGE
90.5%
90.5%
90.5%
90.5%
54 ~ 60V
59 ~ 65V
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
47 ~ 53V
34 ~ 38V
18 ~ 21V
28 ~ 34V
41 ~ 46V
23 ~ 27V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
WORKING TEMP.
-40 ~ +70
VIBRATION
90.5%
0.4A / 277VAC
90
10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
42V
21.6 ~ 36V
5A
OVER CURRENT
OTHERS
36V
RATED POWER
VOLTAGE RANGE
EMC
LPF-90D-54
RATED CURRENT
HOLD UP TIME (Typ.)
SAFETY &
LPF-90D-48
18 ~ 30V
3A
SETUP, RISE TIME
INPUT
LPF-90D-42
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A
267.2Khrs min. MIL-HDBK-217F (25 )
161*61*36mm (L*W*H)
0.7Kg; 20pcs/15Kg/0.73CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:LPF-90D-SPEC 2011-08-12
LPF-90D
90W Single Output Switching Power Supply
Mechanical Specification
Case No.LPF-90A
series
Unit:mm
161
4
4
300 20
4.
300 20
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
61
AC/L(Brown)
AC/N(Blue)
5
SJTW 18AWG 2C
T case
UL2464 18AWG 4C
91
4
9
4.5
4
36
T case: Max. Case Temperature.
Block Diagram
fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
DIM+
DIM-
O.L.P.
O.T.P.
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
50
LOAD (%)
LOAD (%)
60
40
20
-40
-25
-10
0
15
30
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
File Name:LPF-90D-SPEC 2011-08-12
90W Single Output Switching Power Supply
LPF-90D
series
Power Factor Characteristic
Constant Current Mode
1
0 .9 9
0 .9 8
PF
277VAC
230VAC
0 .9 7
115VAC
0 .9 6
0 .9 5
50%
60%
70%
80%
90%
100%
(90W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
LPF-90D series possess superior working efficiency that up to 90.5% can be reached in field applications.
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
277VAC
230VAC
115VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
100
Vo(%)
Constant
Current area
60
(max.)
Hiccup
Protection
50
95
Io (%)
Typical LED power supply I-V curve
File Name:LPF-90D-SPEC 2011-08-12
LPF-90D
90W Single Output Switching Power Supply
series
DIMMING OPERATION
AC/L(Brown)
AC/N(Blue)
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
LPF-90D
Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or
1 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-.
Please DO NOT connect "DIM-" to "-V".
Reference resistance value for output current adjustment (Typical)
OPEN
10K
30K
40K
50K
70K
80K
90K
Single driver
100K
20K
60K
Resistance
Multiple
drivers
value
(N=driver quantity for synchronized 10K
/N 20K /N 30K /N 40K /N 50K /N 60K /N 70K /N 80K /N 90K /N 100K /N
-----
dimming operation)
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
102%~108%
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
102%~108%
10V PWM signal for output current adjustment (Typical): Frequency range:100Hz ~ 3KHz
Duty value
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
102%~108%
Using the built-in dimming function on LPF-90D can't turn the lighting fixture totally dark. Please refer to the connection method below to
achieve 0% brightness of the lighting fixture connecting to the LED power supply unit.
Dimming connection diagram for turning the lighting fixture ON/OFF :
N
L
Switch
Relay
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Brown
Blue
AC/L
LPF-90D
AC/N
DIM+
DIMV(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:LPF-90D-SPEC 2011-08-12