MEANWELL LPF-16D-20

LPF-16D
16W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 305VAC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
Cooling by free air convection
Fully isolated plastic case
Class power unit, no FG
Class 2 power unit
IP67(optional , model NO. : LPF-16D-12 P)
Built-in 3 in 1 dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp location(wet location for LPF-16D-12 P)
3 years warranty
F
110
M
M
SELV
SPECIFICATION
12V
DC VOLTAGE
CONSTANT CURRENT REGION Note.4 6 ~12V
36V
42V
48V
54V
18 ~ 36V
21 ~ 42V
24 ~ 48V
27 ~ 54V
0.45A
0.39A
0.34A
0.3A
0.8A
0.67A
RATED POWER
16.08W
16.05W
16W
16.08W
16.2W
16.2W
16.38W
16.32W
16.2W
150mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
250mVp-p
250mVp-p
350mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE TOLERANCE Note.3
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Note.6 1500ms, 80ms / 115VAC at full load
16ms at full load
Note.5 90 ~ 305VAC
1500ms, 80ms / 230VAC
230VAC /115VAC
127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (Typ.)
83%
84.5%
83%
0.4A / 115VAC
0.2A / 230VAC
COLD START 50A/230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
Note.4
PROTECTION SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
84.5%
84.5%
85%
85%
85%
84.5%
54 ~ 63V
59 ~ 66V
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
34 ~ 40V
15 ~ 18V
17.5 ~ 21V 23 ~ 27V
28 ~ 35V
41 ~ 49V
46 ~ 54V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
100J Ó 5J( TSW1) Detect on U2
Protection type : Shut down o/p voltage, recover automatically after temperature goes down
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent approved, IP67(optional); Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015; EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547,light industry level(surge 2KV), criteria A
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
30V
12 ~ 24V
1.07A
OVER CURRENT
OTHERS
24V
10 ~ 20V
1.34A
VOLTAGE RANGE
EMC
20V
7.5 ~ 15V
RATED CURRENT
HOLD UP TIME (Typ.)
SAFETY &
15V
15 ~ 30V
0.54A
SETUP, RISE TIME
INPUT
( except for 48V,54V )
LPF-16D-12 LPF-16D-15 LPF-16D-20 LPF-16D-24 LPF-16D-30 LPF-16D-36 LPF-16D-42 LPF-16D-48 LPF-16D-54
MODEL
OUTPUT
( for 48V,54V only)
420.1Khrs min. MIL-HDBK-217F (25
148*40*32mm (L*W*H)
0.21Kg;40pcs/9.4Kg/ 1.02CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:LPF-16D-SPEC 2011-12-21
LPF-16D
16W Single Output Switching Power Supply
Mechanical Specification
Case No.: LPF-16A
148
300 20
series
Unit:mm
300 20
SJTW 18AWG*2C
3.6
SVT 18AWG*4C
40
3.6
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
60
13
3.5
AC/N(Blue)
AC/L(Brown)
3.5
3.5
3.5
32
T case: Max. Case Temperature.
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
DIM+
DIM-
O.L.P.
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
LOAD (%)
LOAD (%)
60
40
20
-40
-30
-15
0
15
30
AMBIENT TEMPERATURE (
50
)
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
File Name:LPF-16D-SPEC 2011-12-21
16W Single Output Switching Power Supply
LPF-16D
series
Power Factor Characteristic
Constant Current Mode
PF
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
.9 9
.9 8
.9 7
.9 6
.9 5
.9 4
.9 3
.9 2
.9 1
0 .9
.8 9
.8 8
.8 7
.8 6
.8 5
.8 4
277VAC
230VAC
115VAC
50%
60%
70%
80%
90%
100%
(16W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
LPF-16D series possess superior working efficiency that up to 85% can be reached in field applications.
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
72
71
70
277VAC
230VAC
115VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
(A)
Constant
Current area
Vo(%)
100
50
(max.)
(B)
Hiccup
Protection
50
95
Io(%)
Typical LED power supply I-V curve
File Name:LPF-16D-SPEC 2011-12-21
LPF-16D
16W Single Output Switching Power Supply
series
DIMMING OPERATION
AC/N(Blue)
AC/L(Brown)
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
LPF-16D
Output constant current level can be adjusted through output cable by 1 ~ 10Vdc, 10V PWM signal or resistance between DIM+ and DIM-.
Reference resistance value for output current adjustment (Typical)
Resistance value
Output current
10K
10%
20K
20%
30K
40K
30%
40%
60K
50K
50%
70K
80K
90K
100K
OPEN
60%
70%
80%
90%
100%
95%~108%
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
OPEN
Output current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%~108%
10V PWM signal for output current adjustment (Typical): Frequency range :100~3KHz
Duty value
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
Output current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%~108%
Dimming connection diagram for turning the lighting fixture ON/OFF :
N
L
Switch
Relay
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Brown
Blue
AC/L
LPF-16D
AC/N
DIM+
DIMV(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.