LPV-100 series

L P V- 1 0 0
100W Single Output Switching Power Supply
series
■ Features :
Constant voltage design
Universal AC input / Full range
Fully encapsulated with IP67 level (Note.8)
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Fully isolated plastic case
Cooling by free air convection
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications(Note 7.)
2 years warranty
IP67
SPECIFICATION
MODEL
LPV-100-12
LPV-100-15
LPV-100-24
LPV-100-36
LPV-100-48
5V
12V
15V
24V
36V
48V
RATED CURRENT
12A
8.5A
6.7A
4.2A
2.8A
2.1A
CURRENT RANGE
0 ~ 12A
0 ~ 8.5A
0 ~ 6.7A
0 ~ 4.2A
0 ~ 2.8A
0 ~ 2.1A
RATED POWER
60W
102W
100.5W
100.8W
100.8W
100.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
120mVp-p
150mVp-p
150mVp-p
150mVp-p
VOLTAGE TOLERANCE Note.3 ±8.0%
±5.0%
88%
88%
89%
41.4 ~ 48.6V
55.2 ~ 64.8V
±1.0%
LINE REGULATION
±6.0%
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
50ms/230VAC
Note.4 90 ~ 264VAC
127 ~ 370VDC
47 ~ 63Hz
EFFICIENCY (Typ.)
80%
AC CURRENT
INRUSH CURRENT(Typ.)
2.2A/115VAC 1.2A/230VAC
COLD START 75A(twidth=700μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
85%
87%
0.25mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
-25 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,IP67 approved. Design refer to EN60950-1
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
2000ms, 25ms / 115VAC
14ms/115VAC at full load
FREQUENCY RANGE
LEAKAGE CURRENT
OTHERS
±2.0%
Note.6 2000ms, 25ms / 230VAC
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A(≤80% load), EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A
703Khrs min.
MIL-HDBK-217F (25℃)
190*52*37mm (L*W*H)
0.63Kg;20pcs/13.6Kg/0.55CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure.
‘
OUTPUT
LPV-100-5
DC VOLTAGE
File Name:LPV-100-SPEC 2015-05-28
L P V- 1 0 0
100W Single Output Switching Power Supply
Mechanical Specification
Case No. 999A
300±20
series
Unit:mm
300±20
190
4.5
UL 1015 14AWG
+V(Red)
-V(Black)
DC OUT
ψ
97
T case
30
3.57
AC IN
ψ
4.5
52
UL 1015 18AWG
AC/N(Blue)
AC/L(Brown)
3.57
3.65
3.65
8
37
※ T case: Max. Case Temperature.
Recommend Mounting Direction
Block Diagram
fosc : 65KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
O.L.P.
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
Others
100
90
80
80
5V,12V
70
LOAD (%)
LOAD (%)
60
40
20
-25
-15
0
15
30
40
50
AMBIENT TEMPERATURE (℃)
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:LPV-100-SPEC 2015-05-28