TS-400 series

TS-400
400W True Sine Wave DC-AC Power Inverter
series
■ Features :
True sine wave output (THD<3%)
High surge power up to 800W
High efficiency up to 88.5%
Thermostatically controlled cooling fan
Built-in remote ON-OFF control
Front panel indicator for operation status
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
E13
SPECIFICATION
MODEL
TS-400-112□
INPUT
TS-400-148□
TS-400-212□
400W
MAXIMUM OUTPUT POWER
460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.)
Factory setting set at 110VAC
AC VOLTAGE
OUTPUT
TS-400-124□
RATED POWER
FREQUENCY
TS-400-224□
TS-400-248□
Factory setting set at 230VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W
200 / 220 / 230 / 240VAC selectable by setting button S.W
60±0.1Hz
50±0.1Hz
50/60Hz selectable by setting button
WAVEFORM
Note.2 True sine wave (THD<3%)
AC REGULATION
Note.2 ±3.0% at rated input voltage
50/60Hz selectable by setting button
FRONT PANEL INDICATOR
Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
BAT. VOLTAGE
12V
24V
48V
12V
24V
48V
VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC
DC CURRENT (Typ.)
40A
21 ~ 30VDC
20A
42 ~ 60VDC
10A
10.5 ~ 15VDC
40A
21 ~ 30VDC
20A
42 ~ 60VDC
10A
NO LOAD CURRENT DRAW (Typ.) 1.25A
0.63A
0.32A
1.25A
0.63A
0.32A
87%
86%
87.5%
88.5%
OFF MODE CURRENT DRAW ≦1mA
EFFICIENCY (Typ.)
Note.1 84.5%
BATTERY TYPES
FUSE
BATTERY BAT. LOW ALARM
INPUT
PROTECTION BAT. LOW SHUTDOWN
BAT. POLARITY
OVER TEMPERATURE
OUTPUT SHORT
OUTPUT
PROTECTION
OVER LOAD (Typ.)
GFCI PROCTECTION
FUNCTION REMOTE CONTROL
ENVIRONMENT
40A*1
22.5±4%
20A*1
45±4%
40A*2
11.3±4%
40A*1
22.5±4%
20A*1
45±4%
10.5±4%
21±4%
42±4%
10.5±4%
21±4%
42±4%
75℃± 5℃
70℃± 5℃
85℃± 5℃
75℃± 5℃
70℃± 5℃
By internal fuse open
85℃± 5℃
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
Optional (Only type F)
Open : Normal work ; Short : Remote off
-10 ~ +40℃ @ 100% load ; +60℃ @ 50% load
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
VIBRATION
-30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH
LVD
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
NOTE
40A*2
11.3±4%
WORKING TEMP.
WORKING HUMIDITY
SAFETY STANDARDS
OTHERS
86%
Open & sealed Lead Acid
DIMENSION
PACKING
None
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
None
Design refer to UL458
None
Bat. I/P - AC O/P:3.0KVAC
EN60950-1
AC O/P - FG:1.5KVAC
Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to FCC class A
None
Compliance to EN61000-4-2,3,8
104.7K hrs min.
MIL-HDBK-217F (25℃)
205*158*67mm (L*W*H)
1.73Kg; 6pcs/11.4Kg/1.55CUFT
1.Efficiency is tested by 300W, linear load at 13V/26V/52V input voltage.
2.AC regulation and THD are tested by 400W, linear load at 13V/26V/52V input voltage.
3.The tolerance of each voltage value by models is:112/212→±0.5V;124/224→±1V;148/248→±2V
4.All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
File Name:TS-400-SPEC 2015-05-27
TS-400
400W True Sine Wave DC-AC Power Inverter
TS
400
112 A
A :TYPE
B :TYPE
C :TYPE
D :TYPE
E :TYPE
F :TYPE
12:12VDC
Bat. Voltage: 24:24VDC
48:48VDC
True sine wave inverter
Output:
O/P Wattage:400W
1:110VAC
2:230VAC
A
B
C
D
E
F
series
OUTLET
OUTLET
OUTLET
OUTLET
OUTLET
OUTLET
AC Output Receptacles (optional)
Receptacle type
TYPE-A
TYPE-B
TYPE-C
TYPE-D
TYPE-E
TYPE-F
USA
EUROPE
AUSTRALIA
U.K
JAPAN
GFCI
Country
E13
Certificate
E13
E13
Derating Curve
Mechanical Specification
Unit:mm
R.C Connector : JST B-XH or equivalent
Normal work
Remote off
100
25.32
10.7
Open
Short
80
Chassis
Ground
R.C
LOAD (%)
_
67
60
50
40
20
_ _
OFF
Reverse Polarity
Will Damage The Unit.
ON
11
-10
Air flow
direction
12
18
8.9
0
10
20
30
40
50
60
70
(HORIZONTAL)
42.5
ENVIRONMENT TEMPERATURE (℃)
9
7
AC OUTPUT
Status
205
120
Setting
Type-A
AC OUTPUT
Status
Setting
Type-B
147
158
File Name:TS-400-SPEC 2015-05-27