TS-400 400W True Sine Wave DC-AC Power Inverter series ■ Features : True sine wave output (THD<3%) High surge power up to 800W High efficiency up to 88.5% Thermostatically controlled cooling fan Built-in remote ON-OFF control Front panel indicator for operation status Power ON-OFF switch Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input reverse polarity / Overload Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. 3 years warranty E13 SPECIFICATION MODEL TS-400-112□ INPUT TS-400-148□ TS-400-212□ 400W MAXIMUM OUTPUT POWER 460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.) Factory setting set at 110VAC AC VOLTAGE OUTPUT TS-400-124□ RATED POWER FREQUENCY TS-400-224□ TS-400-248□ Factory setting set at 230VAC 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W 60±0.1Hz 50±0.1Hz 50/60Hz selectable by setting button WAVEFORM Note.2 True sine wave (THD<3%) AC REGULATION Note.2 ±3.0% at rated input voltage 50/60Hz selectable by setting button FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal BAT. VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC DC CURRENT (Typ.) 40A 21 ~ 30VDC 20A 42 ~ 60VDC 10A 10.5 ~ 15VDC 40A 21 ~ 30VDC 20A 42 ~ 60VDC 10A NO LOAD CURRENT DRAW (Typ.) 1.25A 0.63A 0.32A 1.25A 0.63A 0.32A 87% 86% 87.5% 88.5% OFF MODE CURRENT DRAW ≦1mA EFFICIENCY (Typ.) Note.1 84.5% BATTERY TYPES FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN BAT. POLARITY OVER TEMPERATURE OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) GFCI PROCTECTION FUNCTION REMOTE CONTROL ENVIRONMENT 40A*1 22.5±4% 20A*1 45±4% 40A*2 11.3±4% 40A*1 22.5±4% 20A*1 45±4% 10.5±4% 21±4% 42±4% 10.5±4% 21±4% 42±4% 75℃± 5℃ 70℃± 5℃ 85℃± 5℃ 75℃± 5℃ 70℃± 5℃ By internal fuse open 85℃± 5℃ Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover Optional (Only type F) Open : Normal work ; Short : Remote off -10 ~ +40℃ @ 100% load ; +60℃ @ 50% load 20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY VIBRATION -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH LVD SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF NOTE 40A*2 11.3±4% WORKING TEMP. WORKING HUMIDITY SAFETY STANDARDS OTHERS 86% Open & sealed Lead Acid DIMENSION PACKING None 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes None Design refer to UL458 None Bat. I/P - AC O/P:3.0KVAC EN60950-1 AC O/P - FG:1.5KVAC Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to FCC class A None Compliance to EN61000-4-2,3,8 104.7K hrs min. MIL-HDBK-217F (25℃) 205*158*67mm (L*W*H) 1.73Kg; 6pcs/11.4Kg/1.55CUFT 1.Efficiency is tested by 300W, linear load at 13V/26V/52V input voltage. 2.AC regulation and THD are tested by 400W, linear load at 13V/26V/52V input voltage. 3.The tolerance of each voltage value by models is:112/212→±0.5V;124/224→±1V;148/248→±2V 4.All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting. File Name:TS-400-SPEC 2015-05-27 TS-400 400W True Sine Wave DC-AC Power Inverter TS 400 112 A A :TYPE B :TYPE C :TYPE D :TYPE E :TYPE F :TYPE 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC True sine wave inverter Output: O/P Wattage:400W 1:110VAC 2:230VAC A B C D E F series OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET AC Output Receptacles (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Country E13 Certificate E13 E13 Derating Curve Mechanical Specification Unit:mm R.C Connector : JST B-XH or equivalent Normal work Remote off 100 25.32 10.7 Open Short 80 Chassis Ground R.C LOAD (%) _ 67 60 50 40 20 _ _ OFF Reverse Polarity Will Damage The Unit. ON 11 -10 Air flow direction 12 18 8.9 0 10 20 30 40 50 60 70 (HORIZONTAL) 42.5 ENVIRONMENT TEMPERATURE (℃) 9 7 AC OUTPUT Status 205 120 Setting Type-A AC OUTPUT Status Setting Type-B 147 158 File Name:TS-400-SPEC 2015-05-27