TS-400 400W True Sine Wave DC-AC Power Inverter series Features : True sine wave output (THD<3%) High surge power up to 800W High efficiency up to 88.5% Thermostatically controlled cooling fan Built-in remote ON-OFF control Front panel indicator for operation status Power ON-OFF switch Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input reverse polarity / Overload Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. 3 years warranty E13 SPECIFICATION MODEL 460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.) Factory setting set at 110VAC Factory setting set at 230VAC 200 / 220 / 230 / 240VAC selectable by setting button S.W 60 0.1Hz 50 0.1Hz WAVEFORM True sine wave (THD<3%) at rated input voltage Note.2 50/60Hz selectable by setting button 50/60Hz selectable by setting button 3.0% at rated input voltage FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal BAT. VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) DC CURRENT (Typ.) 10.5 ~ 15VDC 40A 21 ~ 30VDC 20A 42 ~ 60VDC 10A 10.5 ~ 15VDC 40A 21 ~ 30VDC 20A 42 ~ 60VDC 10A 0.63A 0.32A 1.25A 0.63A 0.32A 87% 86% 87.5% 88.5% NO LOAD CURRENT DRAW (Typ.) 1.25A EFFICIENCY (Typ.) 1mA 86% Open & sealed Lead Acid Note.1 84.5% FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN BAT. POLARITY OVER TEMPERATURE OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) GFCI PROCTECTION FUNCTION REMOTE CONTROL 40A*2 11.3 4% 40A*1 22.5 4% 20A*1 45 4% 40A*2 11.3 4% 40A*1 22.5 4% 20A*1 45 4% 10.5 4% 21 4% 42 4% 10.5 4% 21 4% 42 4% 85 75 By internal fuse open 85 75 5 5 70 5 5 70 5 Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover Optional (Only type F) Open : Normal work ; Short : Remote off -10 ~ +40 @ 100% load ; +60 20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY VIBRATION -30 ~ +70 LVD SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE EMC EMISSION 5 Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor WORKING TEMP. WORKING HUMIDITY SAFETY STANDARDS NOTE TS-400-248 FREQUENCY BATTERY TYPES OTHERS TS-400-224 100 / 110 / 115 / 120VAC selectable by setting button S.W OFF MODE CURRENT DRAW ENVIRONMENT TS-400-212 MAXIMUM OUTPUT POWER AC REGULATION INPUT TS-400-148 400W AC VOLTAGE OUTPUT TS-400-124 TS-400-112 RATED POWER None @ 50% load o / -22 ~ +158 F, 10 ~ 95% RH 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes None Design refer to UL458 None Bat. I/P - AC O/P:3.0KVAC EN60950-1 AC O/P - FG:1.5KVAC Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25 Compliance to FCC class A None EMC IMMUNITY MTBF 104.7K hrs min. DIMENSION PACKING 205*158*67mm (L*W*H) 1.73Kg; 6pcs/11.4Kg/1.55CUFT / 70% RH Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN61000-4-2,3,8 MIL-HDBK-217F (25oC) 1.Efficiency is tested by 300W, linear load at 13V/26V/52V input voltage. 2.AC regulation is tested at 13V/26V/52V input voltage. File Name:TS-400-SPEC 2012-03-20 TS-400 400W True Sine Wave DC-AC Power Inverter TS 400 112 A A :TYPE B :TYPE C :TYPE D :TYPE E :TYPE F :TYPE 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC True sine wave inverter Output: O/P Wattage:400W 1:110VAC 2:230VAC A B C D E F series OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET AC Output Receptacles (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Country E13 Certificate E13 E13 Derating Curve Mechanical Specification Unit:mm R.C Connector : JST B-XH or equivalent Normal work Remote off 100 25.32 10.7 Open Short 80 Chassis Ground R.C LOAD (%) _ 67 60 50 40 20 _ _ OFF Reverse Polarity Will Damage The Unit. ON 11 -10 Air flow direction 12 18 8.9 0 10 20 30 40 50 60 70 (HORIZONTAL) 42.5 ENVIRONMENT TEMPERATURE ( ) 9 7 AC OUTPUT Status 205 120 Setting Type-A AC OUTPUT Status Setting Type-B 147 158 File Name:TS-400-SPEC 2012-03-20