TS-3000 3000W True Sine Wave DC-AC Inverter series Features : True sine wave output (THD<3%) High surge power up to 6000W High efficiency up to 92% Power ON-OFF switch Standby saving mode can be selectable Front panel indicator for operation status Thermostatically controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload / AC circuit breaker Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. Optional monitoring software and connection cable (MW order No.: DS-TN-1500) 3 years warranty E13 SPECIFICATION MODEL TS-3000-124 TS-3000-112 TS-3000-148 TS-3000-212 TS-3000-224 TS-3000-248 3000W RATED POWER (Typ.) MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles Factory setting set at 110VAC Factory setting set at 230VAC 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W FREQUENCY 60 0.1Hz 50 0.1Hz WAVEFORM True sine wave (THD<3%) at rated input voltage AC VOLTAGE OUTPUT 50/60Hz selectable by setting button S.W 3% AC REGULATION (Typ.) SAVING MODE (Typ.) Default disabled. Load FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE 12V VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC DC CURRENT (Typ.) INPUT Note.4 300A 5W will be changed to standby mode 24V 48V 12V 24V 48V 21 ~ 30VDC 150A 42 ~ 60VDC 75A 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 300A 150A 75A 91% 89% 91% 92% 20A*6 45V 40A*12 11.3V 40A*6 22.5V 20A*6 45V 42V 10.5V 21V 42V NO LOAD DISSIPATION (Typ.) 10W @ standby saving mode OFF MODE CURRENT DRAW (Typ.) 1mA EFFICIENCY (Typ.) 90% Open & sealed lead acid battery Note.1 88% BATTERY TYPES FUSE 40A*6 40A*12 BATTERY BAT. LOW ALARM 22.5V Note.6 11.3V INPUT 21V PROTECTION BAT. LOW SHUTDOWN Note.6 10.5V By internal fuse open REVERSE POLARITY 90 OVER TEMPERATURE SAFETY & EMC NOTE 5 85 5 5 75 5 75 5 Protection type : Shut down o/p voltage, re-power on to recover AC output receptacle:15A Optional (Only type F) @ 100% load ; 60 @ 50% load 20% ~ 90% RH non-condensing None Note.2 0 ~ +40 STORAGE TEMP., HUMIDITY VIBRATION -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH SAFETY STANDARDS 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes UL458 (only for "GFCI" receptacle-Type F ) None LVD WITHSTAND VOLTAGE None Bat I/P - AC O/P:3.0KVAC ISOLATION RESISTANCE EMC EMISSION DIMENSION PACKING 80 Protection type : Shut down o/p voltage, re-power on to recover WORKING HUMIDITY EMC IMMUNITY CONTROL WIRING OTHERS 85 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. CIRCUIT BREAKER GFCI PROCTECTION WORKING TEMP. 5 Protection type : Shut down o/p voltage, re-power on to recover OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) ENVIRONMENT 50/60Hz selectable by setting button S.W EN60950-1 AC O/P - FG:1.5KVAC Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25 / 70% RH Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to FCC class A None Compliance to EN61000-4-2,3,4,5,6,8,11 RJ11 -RS232 (Option) 466.8*283.5*100mm (L*W*H) 12.9Kg; 1pcs/14Kg/1.98CUFT 1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage. 2.Output derating capacity referenced by curve 1. 3.Output derating capacity referenced by curve 2. 4.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage. 5.All parameters not specified above are measured at rated load, 25 of ambient temperature. 6.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V File Name:TS-3000-SPEC 2011-05-24 TS-3000 3000W True Sine Wave DC-AC Inverter TS 3000 112 A A :TYPE A OUTLET B :TYPE B OUTLET C :TYPE C OUTLET D :TYPE D OUTLET E :TYPE E OUTLET F :TYPE F OUTLET 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC TS:True sine wave inverter Output: O/P Wattage:3000W series 1:110VAC 2:230VAC AC Output Receptacle (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Country E13 Certificate E13 E13 (Expect for 48V input) Derating Curve Mechanical Specification Unit:mm 161.84 122.44 100 LOAD (%) POS 100 31.6 80 60 40 NEG Reverse Polarity Will Damage The Unit. 20 0 46 Air flow direction 10 20 30 40 50 60 70 AMBIENT TEMPERATURE ( ) CURVE 1 Air flow direction 100 LOAD (%) 90.3 80 7 7.5 60 40 20 10.5VDC 11.5VDC 15VDC (HORIZONTAL) AC Receptacle 466.8 286.2 BATTERY INPUT VOLTAGE (V) CURVE 2 ON OFF 100 BATTERY INVERTER i t Br e r Ci er Setting On 0 0 t Pr Bat Low se e s LOAD 100 ak cu s t o R e Saving Chassis Ground Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) 13 Remote port AC OUTPUT 31.29 Type-A NC NC AC OUTPUT L Note: When the load current is >15A, must use output terminal connection which can be found inside the AC output panel of the inverter. FG N AC Receptacle ON OFF 100 r Ci 12 er 34 e 283.5 Setting 0 s t o R Bat Low e Saving Chassis Ground Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) Remote port 13 273 LOAD 100 On 0 se t Pr s BATTERY INVERTER i t Br e ak cu AC OUTPUT 31.29 Type-B File Name:TS-3000-SPEC 2011-05-24