TS-200 200W True Sine Wave DC-AC Power Inverter series Features : True sine wave output (THD<3%) High surge power up to 400W High efficiency up to 88% Fanless design, cooling by free air convention Built-in remote ON-OFF control Front panel indicator for operation status Power ON-OFF switch Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input reverse polarity / Overload Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. 3 years warranty E13 SPECIFICATION MODEL 230W for 180 sec. / 300W for 10 sec. / surge power 400W for 30 cycles(typ.) Factory setting set at 230VAC 200 / 220 / 230 / 240VAC selectable by setting button S.W FREQUENCY 60 0.1Hz 50 0.1Hz WAVEFORM True sine wave (THD<3%) at rated input voltage 50/60Hz selectable by setting button 50/60Hz selectable by setting button 3.0% at rated input voltage FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal BAT. VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) DC CURRENT (Typ.) 10.5 ~ 15VDC 20A 21 ~ 30VDC 10A 42 ~ 60VDC 5A 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 20A 10A 5A 0.63A 0.32A 1.25A 0.63A 0.62A 87.5% Open & sealed Lead Acid 88% 86% 87.5% 88% 30A*2 11.3 4% 30A*1 22.5 4% 15A*1 45 4% 30A*2 11.3 4% 30A*1 22.5 4% 15A*1 45 4% 10.5 4% 21 4% 42 4% 10.5 4% 21 4% 42 4% 85 80 NO LOAD CURRENT DRAW (Typ.) 1.25A EFFICIENCY (Typ.) 1mA Note.1 86% FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN BAT. POLARITY OVER TEMPERATURE OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) GFCI PROCTECTION By internal fuse open 85 80 5 5 80 5 5 5 Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY -10 ~ +35 @ 100% load ; +60 20% ~ 90% RH non-condensing -10 ~ +40 STORAGE TEMP., HUMIDITY VIBRATION -30 ~ +70 LVD SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE 80 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. None SAFETY STANDARDS 5 Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor Optional (Only type F) Open : Normal work ; Short : Remote off FUNCTION REMOTE CONTROL @ 50% load @ 100% load, +60 @ 50% load / -22 ~ +158oF, 10 ~ 95% RH 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes None Design refer to UL458 None Bat. I/P - AC O/P:3.0KVAC EN60950-1 AC O/P - FG:1.5KVAC Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION&RADIATION Compliance to FCC class A None EMS IMMUNITY NOTE TS-200-248 Factory setting set at 110VAC BATTERY TYPES OTHERS TS-200-224 100 / 110 / 115 / 120VAC selectable by setting button S.W OFF MODE CURRENT DRAW ENVIRONMENT TS-200-212 MAXIMUM OUTPUT POWER AC REGULATION (Typ.) INPUT TS-200-148 200W AC VOLTAGE OUTPUT TS-200-124 TS-200-112 RATED POWER / 70% RH Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN61000-4-2,3,8 ENV50204 MIL-HDBK-217F (25oC) MTBF 106.2K hrs min. DIMENSION PACKING 205*158*59mm (L*W*H) 1.63Kg; 6pcs/10.8Kg/1.44CUFT 1.Efficiency is tested by 200W, linear load at 12V/24V/48V input voltage. 2.All parameters not specified above are measured at rated load, 25 of ambient temperature. File Name:TS-200-SPEC 2010-11-01 TS-200 200W True Sine Wave DC-AC Power Inverter TS 200 112 A A :TYPE B :TYPE C :TYPE D :TYPE E :TYPE F :TYPE 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC True sine wave inverter Output: O/P Wattage:200W 1:110VAC 2:230VAC A B C D E F series OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET AC Output Receptacles (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Country E13 Certificate E13 E13 Derating Curve Mechanical Specification Unit:mm R.C Connector : JST B-XH or equivalent Normal work Remote off 100 24.82 10.7 Open Short TS-200-2xx 80 Chassis Ground R.C _ LOAD (%) 59 60 TS-200-1xx 50 40 20 _ _ OFF Reverse Polarity Will Damage The Unit. ON 11 8.9 0 10 20 30 35 40 50 60 12 18 -10 70 (HORIZONTAL) 42.5 ENVIRONMENT TEMPERATURE ( ) 7 9 AC OUTPUT Status 205 120 Setting Type-A Status AC OUTPUT Setting Type-B 147 158 File Name:TS-200-SPEC 2010-11-01