TS-1500 1500W True Sine Wave DC-AC Power Inverter series Features : True sine wave output (THD<3%) High surge power up to 3000W High efficiency up to 91% Power ON-OFF switch Standby saving mode can be selectable Front panel indicator for operation status Thermostatically controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. Optional monitoring software E13 2 years warranty SPECIFICATION MODEL OUTPUT TS-1500-112 TS-1500-124 TS-1500-148 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles AC VOLTAGE 100 / 110 / 115 / 120VAC selectable by setting button 200 / 220 / 230 / 240VAC selectable by setting button FREQUENCY 60 0.1Hz 50 0.1%Hz WAVEFORM True sine wave (THD<3%) at rated input voltage 50/60Hz selectable by setting button S.W Load FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE 12V 5W will be changed to standby mode 24V 48V 12V 24V 48V 42 ~ 60VDC 37.5A 10.5 ~ 15VDC 150A 21 ~ 30VDC 42 ~ 60VDC 75A 37.5A 89% Open & sealed Lead Acid 90% 88% 90% 91% 40A*5 11.3 4% 30A*3 22.5 4% 30A*2 45 4% 40A*5 11.3 4% 30A*3 22.5 4% 30A*2 45 4% 10.5 4% 21 4% 42 4% 10.5 4% 21 4% 42 4% 68 68 21 ~ 30VDC 75A 18W @ standby saving mode NO LOAD DISSIPATION EFFICIENCY (Typ.) 1mA Note.2 87% BATTERY TYPES FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN REVERSE POLARITY By internal fuse open 82 OVER TEMPERATURE 82 5 96 5 5 5 68 5 Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover GFCI PROCTECTION Optional (Only type F) @ 100% load ; 60 @ 50% load 20% ~ 90% RH non-condensing None Note.3 0 ~ +40 STORAGE TEMP., HUMIDITY VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC EMI CONDUCTION&RADIATION EMS IMMUNITY NOTE 5 Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power transistor OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) WORKING TEMP. WORKING HUMIDITY 50/60Hz selectable by setting button S.W 3.0% SAVING MODE (Typ.) OFF MODE CURRENT DRAW OTHERS TS-1500-248 MAXIMUM OUTPUT POWER VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC DC CURRENT (Typ.) Note.5 150A ENVIRONMENT TS-1500-224 1500W AC REGULATION (Typ.) INPUT TS-1500-212 RATED POWER (Typ.) -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes UL458 (only for type F) Bat I/P - AC O/P:3.0KVAC EN60950-1 AC O/P - FG:1.5KVAC Compliance to FCC class A ----- CONTROL WIRING RJ11 -RS232 (Option) DIMENSION PACKING 420*220*88mm (L*W*H) 6.81Kg; 2pcs/14.6Kg/1.61CUFT Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN61000-4-2,3,8 ENV50204 1.Output derating capacity referenced by curve 1. 2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage. 3.Output derating capacity referenced by curve 2. 4.All parameters not specified above are measured at rated load, 25 of ambient temperature. 5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage. File Name:TS-1500-SPEC 2008-07-29 TS-1500 1500W True Sine Wave DC-AC Power Inverter TS 1500 112 A A :TYPE A OUTLET B :TYPE B OUTLET C :TYPE C OUTLET D :TYPE D OUTLET E :TYPE E OUTLET F :TYPE F OUTLET 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC TS:True sine wave inverter Output: O/P Wattage:1500W series 1:110VAC 2:230VAC AC Output Receptacles (optional) TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Mechanical Specification Unit:mm 11.05 12.1 Inverter ENG DC INPUT POS 108.4 Chassis Ground Inverter Inverter 27.45 Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) Inverter 48 57.75 36.25 15.6 Air flow direction WARNING: Reverse Polarity Will Damage The 203.2 420 7 10 AC OUTPUT ON BATTERY Setting LOAD OFF 100 100 INVERTER On 0 Bat Low 0 Saving Remote port Type-A AC OUTPUT ON BATTERY Setting LOAD OFF 100 100 INVERTER On 0 Bat Low 0 Saving Remote port 207 220 Type-B File Name:TS-1500-SPEC 2008-07-29