MEANWELL TS-1500

TS-1500
1500W True Sine Wave DC-AC Power Inverter
series
Features :
True sine wave output (THD<3%)
High surge power up to 3000W
High efficiency up to 91%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Optional monitoring software
E13
2 years warranty
SPECIFICATION
MODEL
OUTPUT
TS-1500-112
TS-1500-124
TS-1500-148
1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button
200 / 220 / 230 / 240VAC selectable by setting button
FREQUENCY
60 0.1Hz
50 0.1%Hz
WAVEFORM
True sine wave (THD<3%) at rated input voltage
50/60Hz selectable by setting button S.W
Load
FRONT PANEL INDICATOR
Battery voltage level, output load level, saving mode, fault and operation status
BAT. VOLTAGE
12V
5W will be changed to standby mode
24V
48V
12V
24V
48V
42 ~ 60VDC
37.5A
10.5 ~ 15VDC
150A
21 ~ 30VDC
42 ~ 60VDC
75A
37.5A
89%
Open & sealed Lead Acid
90%
88%
90%
91%
40A*5
11.3 4%
30A*3
22.5 4%
30A*2
45 4%
40A*5
11.3 4%
30A*3
22.5 4%
30A*2
45 4%
10.5 4%
21 4%
42 4%
10.5 4%
21 4%
42 4%
68
68
21 ~ 30VDC
75A
18W @ standby saving mode
NO LOAD DISSIPATION
EFFICIENCY (Typ.)
1mA
Note.2 87%
BATTERY TYPES
FUSE
BATTERY BAT. LOW ALARM
INPUT
PROTECTION BAT. LOW SHUTDOWN
REVERSE POLARITY
By internal fuse open
82
OVER TEMPERATURE
82
5
96
5
5
5
68
5
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION
Optional (Only type F)
@ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
None
Note.3 0 ~ +40
STORAGE TEMP., HUMIDITY
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
EMI CONDUCTION&RADIATION
EMS IMMUNITY
NOTE
5
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power transistor
OUTPUT SHORT
OUTPUT
PROTECTION
OVER LOAD (Typ.)
WORKING TEMP.
WORKING HUMIDITY
50/60Hz selectable by setting button S.W
3.0%
SAVING MODE (Typ.)
OFF MODE CURRENT DRAW
OTHERS
TS-1500-248
MAXIMUM OUTPUT POWER
VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC
DC CURRENT (Typ.)
Note.5 150A
ENVIRONMENT
TS-1500-224
1500W
AC REGULATION (Typ.)
INPUT
TS-1500-212
RATED POWER (Typ.)
-30 ~ +70
/ -22 ~ +158oF, 10 ~ 95% RH
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
UL458 (only for type F)
Bat I/P - AC O/P:3.0KVAC
EN60950-1
AC O/P - FG:1.5KVAC
Compliance to FCC class A
-----
CONTROL WIRING
RJ11 -RS232 (Option)
DIMENSION
PACKING
420*220*88mm (L*W*H)
6.81Kg; 2pcs/14.6Kg/1.61CUFT
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN61000-4-2,3,8 ENV50204
1.Output derating capacity referenced by curve 1.
2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.
3.Output derating capacity referenced by curve 2.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.
File Name:TS-1500-SPEC 2008-07-29
TS-1500
1500W True Sine Wave DC-AC Power Inverter
TS
1500
112 A
A :TYPE A OUTLET
B :TYPE B OUTLET
C :TYPE C OUTLET
D :TYPE D OUTLET
E :TYPE E OUTLET
F :TYPE F OUTLET
12:12VDC
Bat. Voltage: 24:24VDC
48:48VDC
TS:True sine wave inverter
Output:
O/P Wattage:1500W
series
1:110VAC
2:230VAC
AC Output Receptacles (optional)
TYPE-A
TYPE-B
TYPE-C
TYPE-D
TYPE-E
TYPE-F
USA
EUROPE
AUSTRALIA
U.K
JAPAN
GFCI
Mechanical Specification
Unit:mm
11.05
12.1
Inverter
ENG
DC
INPUT
POS
108.4
Chassis
Ground
Inverter
Inverter
27.45
Cat.No.(1GG1HS-212)
Wire Range(10-4 AWG Str
Cu Soldered Wires)
Torque (17.7-26.5 in lb)
Inverter
48
57.75
36.25
15.6
Air flow
direction
WARNING:
Reverse Polarity
Will Damage The
203.2
420
7
10
AC OUTPUT
ON
BATTERY
Setting
LOAD
OFF
100
100
INVERTER
On
0
Bat Low
0
Saving
Remote
port
Type-A
AC OUTPUT
ON
BATTERY
Setting
LOAD
OFF
100
100
INVERTER
On
0
Bat Low
0
Saving
Remote
port
207
220
Type-B
File Name:TS-1500-SPEC 2008-07-29