Harwin Test Report Summary HT02502 Detailed Environmental Testing of Datamate (M80 Series) Connectors HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing 1. Introduction. 1.1. Description and Purpose. The Harwin Datamate (M80 Series) connector is manufactured to the requirements of BS9525F0033 and has been designed to withstand 500 successive engagements and separations without impairing its mechanical or electrical performance. The following tests were carried out to establish whether the connector’s performance would be impaired when subjected to bump, shock and vibration above the levels specified in BS9525-F0033. 1.2. Conclusion. The following data has been collated from Harwin test report ET3858. During the product testing no mechanical failures occurred, connectors remained latched together securely and no electrical discontinuity was observed. The results contained within this report are representative of all M80 series connectors utilising latches. Unlatched and friction latch connectors may perform differently when subjected to the intensive test methods used within this report. Results: Sample 1 Bump OK Vibration OK Shock OK Visual Examination OK Test Method, Requirements and Results. 1.3. List of Test Samples. Mated sample Male connector (L-Tek with locking latch) Female connector (L-Tek) 1 M80-8531042 M80-8501042 Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 2 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing 1.4. Specification Parameters. BS9520 Parameters Vibration A.) Test 1.2.6.3.1 Vibration B.) 1.2.6.3.1 Vibration C.) 1.2.6.3.1 In general accordance with BS2011: Part 2.1 Fc: 1977 10Hz to 2kHz 1.5mm peak/10g duration 1.5 hours total (0.5hr/axis) Continuously monitoring of electrical continuity during frequency sweep In general accordance with BS2011: Part 2.1 Fc: 1977 10Hz to 2kHz 1.5mm peak/20g duration 1.5 hours total (0.5hr/axis) Continuously monitoring of electrical continuity during frequency sweep In general accordance with BS2011: Part 2.1 Fc: 1977 10Hz to 2kHz 1.5mm peak/20g duration 6 hours total (2hr/axis) Continuously monitoring of electrical continuity during frequency sweep In general accordance with BS2011: Part 2.1 Ea: 1977. 981 m/s2 (100g) 1msTrapezoidal pulse, both directions of three axis, 6 shocks total, continuously monitoring of electrical continuity during application of shocks Shock D.) 1.2.6.4 Bump E.) 1.2.6.2 In general accordance with BS2011: Part 2.1 Eb: 1977 390 m/s2 (40g) 10ms 4000 ±40 Bumps, both directions of three axis continuously monitoring of electrical continuity during the last 200 bumps 1.2.2 (d) Mechanical damage, movement or displacement of parts such as would impair operation Visual Examination Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 3 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing 1.5. Test Method and Results. All tests were carried out with connectors in the mated condition. A. Vibration – 10g The sample was subjected to a Swept Sine Test carried out generally in accordance with BS 9525 and BS EN 60068-2-6 test Fc, under the following conditions: 10-57.55Hz @ 1.5mm peak-peak, 57.55-2000Hz @ 10g. Sweep rate 1 octave/minute for 30 minutes in each axis, intermittencies on each connector to be recorded. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 4 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 5 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing B. Vibration – 20g The sample was subjected to a Swept Sine Test carried out generally in accordance with BS 9525 and BS EN 60068-2-6 test Fc, under the following conditions: 10-81.73Hz @ 1.5mm peak-peak, 57.55-2000Hz @ 20g. Sweep rate 1 octave/minute for 30 minutes, intermittencies on each connector to be recorded. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 6 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing C. Vibration – 20g The sample was subjected to a Swept Sine Test carried out generally in accordance with BS 9525 and BS EN 60068-2-6 test Fc, under the following conditions: 10-81.73Hz @ 1.5mm peak-peak, 57.55-2000Hz @ 20g. Sweep rate 1 octave/minute for 2 hours, intermittencies on each connector to be recorded. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 7 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 8 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing D. Shock – 100g The sample was subjected to a Shock Test carried out generally in accordance with BS 9525 and BS EN 60068-2-6 test Ea, under the following conditions: Severity = 100g, duration = 1ms, shape = trapezoidal, number of shocks = 1 per direction, 2 per axis, 6 in total. Z Axis Negative Velocity Pulse: Black: control. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 9 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing Z Axis Negative Velocity Pulse: Black: Control. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 10 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing E. Bump – 40g The sample was subjected to a Bump Test carried out generally in accordance with BS 9525 and BS EN 60068-2-27 test Ea, under the following conditions: Severity = 40g, duration = 10ms, shape = Half-sine, number of bumps = 666 per direction, 1333 per axis, 4000 in total. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 11 of 12 HT02502 Test Report for Datamate (M80 Series) – Detailed Environmental Testing Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 2 Date: 05/08/2013 C/Note: 12173 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 12 of 12