Harwin Test Report Summary HT02701 Environmental Testing of EZ-BoardWare Coin Cell Holders (S8401-46, S8411-45R, S8421-45R and S8211-46R) HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing 1. Introduction. 1.1. Description and Purpose. The purpose of this test program is to confirm the vibration, shock and bump performance of Harwin Coin Cell Holders S8401-46, S8411-45R, S8421-45R and S8211-46R. 1.2. Conclusion. The following test data has been taken from Harwin test report ET3858. Test Duration Axis Z Axis Vibration (best test result shown) See results Y Axis X Axis Shock 100g Shock 50g Shock 50g 1ms Bump 40g 10ms Z Axis Y Axis X Axis Z Axis Y Axis X Axis S8401-46 Passed 20g, 120 minutes Passed 10g, 30 minutes Passed 20g, 120 minutes Passed Passed Passed Passed Passed Passed S8411-45R Passed 20g, 120 minutes Passed 20g, 120 minutes Passed 20g, 120 minutes Passed Passed Passed Passed Passed Passed S8421-45R Passed 20g, 120 minutes Passed 20g, 120 minutes Passed 20g, 120 minutes Passed Passed Passed Passed Passed Passed S8211-46R Discontinuity Detected 10g Passed 5g, 120 minutes Passed 5g, 120 minutes Not Tested Not Tested Not Tested Not Tested Not Tested Not Tested All discontinuity measurements were taken at 10 micro seconds (100 kHz) intervals. 2. Test Method, Requirements and Results. 2.1. List of Test Samples. a) S8401-46 Vertical PC Tail coin cell holder for Ø20mm battery b) S8411-45R Horizontal SMT coin cell holder for Ø20mm battery c) S8421-46R Horizontal SMT coin cell holder for Ø12mm battery d) S8211-46R Horizontal SMT one-piece coin cell holder for Ø20mm battery 2.2. Specification Parameters. The testing performed included: a) Swept Sine (Vibration): generally in accordance with BS9525 and BS EN 60068-2-6 test Fc. b) Shock: generally in accordance with BS9525 and BS EN 60068-2-27 test Ea. c) Bump: generally in accordance with BS9525 and BS EN 60068-2-27 test Ea. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 2 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing 2.3. Test Method and Results. a) Vibration 10g & 5g The sample was subjected to a Swept Sine Test carried out generally in accordance with BS 9525 and BS EN 60068-2-6 test Fc, under the following conditions: 10-57.55Hz @ 1.5mm peak-peak, 57.55-2000Hz @ 10g. Sweep rate 1 octave/minute for 30 minutes in each axis, intermittencies on each connector to be recorded. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 3 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing During the Z-axis continuity test (completed first), coin cells held in S8211-46R had vibrated loose during the vibration sweep at around 1149Hz and discontinuity occurred. The coin cells were placed back into the holders before further testing was carried out at a reduced 5g (10-40.69Hz @ 1.5mm peak-peak, 57.55-2000Hz @ 5g, sweep rate 1 octave/minute), and were tested for both 30 minutes and 120 minutes. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 4 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 5 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 6 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing b) Vibration 20g The sample was subjected to a Swept Sine Test carried out generally in accordance with BS 9525 and BS EN 60068-2-6 test Fc, under the following conditions: 10-81.73Hz @ 1.5mm peak-peak, 57.55-2000Hz @ 20g. Sweep rate 1 octave/minute for 30 minutes, followed by 2 hours in each axis if no intermittencies are recorded during the 30 minute duration, intermittencies on each connector to be recorded. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 7 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing During this test coin cells held in S8401-46 vibrated at the higher frequencies and discontinuity occurred. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 8 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 9 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing c) Shock 100g The sample was subjected to a Shock Test carried out generally in accordance with BS 9525 and BS EN 60068-2-6 test Ea, under the following conditions: Severity = 100g, duration = 1ms, shape = trapezoidal, number of shocks = 1 per direction, 2 per axis, 6 in total. Z Axis Negative Velocity Pulse: Black: control. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 10 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 11 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing d) Bump 40g The sample was subjected to a Bump Test carried out generally in accordance with BS 9525 and BS EN 60068-2-27 test Ea, under the following conditions: Severity = 40g, duration = 10ms, shape = Half-sine, number of bumps = 666 per direction, 1333 per axis, 4000 in total. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 12 of 13 HT02701 Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 09/12/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 13 of 13