Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
1. Introduction.
1.1.
Description and Purpose.
The purpose of this test program is to confirm the vibration, shock and bump performance of
Harwin Coin Cell Holders S8401-46, S8411-45R, S8421-45R and S8211-46R.
1.2. Conclusion.
The following test data has been taken from Harwin test report ET3858.
Test
Duration
Axis
Z Axis
Vibration
(best test
result shown)
See
results
Y Axis
X Axis
Shock 100g
Shock 50g
Shock 50g
1ms
Bump 40g
10ms
Z Axis
Y Axis
X Axis
Z Axis
Y Axis
X Axis
S8401-46
Passed 20g,
120 minutes
Passed 10g,
30 minutes
Passed 20g,
120 minutes
Passed
Passed
Passed
Passed
Passed
Passed
S8411-45R
Passed 20g,
120 minutes
Passed 20g,
120 minutes
Passed 20g,
120 minutes
Passed
Passed
Passed
Passed
Passed
Passed
S8421-45R
Passed 20g,
120 minutes
Passed 20g,
120 minutes
Passed 20g,
120 minutes
Passed
Passed
Passed
Passed
Passed
Passed
S8211-46R
Discontinuity
Detected 10g
Passed 5g,
120 minutes
Passed 5g,
120 minutes
Not Tested
Not Tested
Not Tested
Not Tested
Not Tested
Not Tested
All discontinuity measurements were taken at 10 micro seconds (100 kHz) intervals.
2. Test Method, Requirements and Results.
2.1. List of Test Samples.
a)
S8401-46 Vertical PC Tail coin cell holder for Ø20mm battery
b)
S8411-45R Horizontal SMT coin cell holder for Ø20mm battery
c)
S8421-46R Horizontal SMT coin cell holder for Ø12mm battery
d)
S8211-46R Horizontal SMT one-piece coin cell holder for Ø20mm battery
2.2. Specification Parameters.
The testing performed included:
a)
Swept Sine (Vibration): generally in accordance with BS9525 and BS EN 60068-2-6 test Fc.
b)
Shock: generally in accordance with BS9525 and BS EN 60068-2-27 test Ea.
c)
Bump: generally in accordance with BS9525 and BS EN 60068-2-27 test Ea.
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 2 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
2.3. Test Method and Results.
a)
Vibration 10g & 5g
The sample was subjected to a Swept Sine Test carried out generally in accordance with
BS 9525 and BS EN 60068-2-6 test Fc, under the following conditions:
10-57.55Hz @ 1.5mm peak-peak, 57.55-2000Hz @ 10g. Sweep rate 1 octave/minute for 30
minutes in each axis, intermittencies on each connector to be recorded.
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 3 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
During the Z-axis continuity test (completed first), coin cells held in S8211-46R had
vibrated loose during the vibration sweep at around 1149Hz and discontinuity occurred.
The coin cells were placed back into the holders before further testing was carried out at a
reduced 5g (10-40.69Hz @ 1.5mm peak-peak, 57.55-2000Hz @ 5g, sweep rate 1
octave/minute), and were tested for both 30 minutes and 120 minutes.
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 4 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 5 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 6 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
b)
Vibration 20g
The sample was subjected to a Swept Sine Test carried out generally in accordance with
BS 9525 and BS EN 60068-2-6 test Fc, under the following conditions:
10-81.73Hz @ 1.5mm peak-peak, 57.55-2000Hz @ 20g. Sweep rate 1 octave/minute for 30
minutes, followed by 2 hours in each axis if no intermittencies are recorded during the 30
minute duration, intermittencies on each connector to be recorded.
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 7 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
During this test coin cells held in S8401-46 vibrated at the higher frequencies and
discontinuity occurred.
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 8 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 9 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
c)
Shock 100g
The sample was subjected to a Shock Test carried out generally in accordance with BS
9525 and BS EN 60068-2-6 test Ea, under the following conditions:
Severity = 100g, duration = 1ms, shape = trapezoidal, number of shocks = 1 per direction, 2
per axis, 6 in total.
Z Axis Negative Velocity Pulse: Black: control.
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 10 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 11 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
d)
Bump 40g
The sample was subjected to a Bump Test carried out generally in accordance with BS
9525 and BS EN 60068-2-27 test Ea, under the following conditions:
Severity = 40g, duration = 10ms, shape = Half-sine, number of bumps = 666 per direction,
1333 per axis, 4000 in total.
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 12 of 13
HT02701
Test Report: EZ-BoardWare Coin Cell Holders Environmental Testing
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 09/12/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 13 of 13