THERMATEL® TA2 Thermal Mass Flow Transmitter DESCRIPTION Thermatel Model TA2 Thermal Mass Flow Transmitter provides reliable mass measurement for air and gas flow applications. The powerful, yet easy to use, electronics are contained in a compact explosion proof enclosure. The TA2 offers excellent performance at exceptional value. For air and gases F E AT U R E S • • • • • • • • • • • • • • Direct mass flow measurement of air and gases. No need for temperature/pressure correction. High turndown ratio 100:1. Excellent low flow sensitivity. Low pressure drop. Flow, temperature and totalized flow available over HART®. Advanced diagnostics check condition of probe, electronics, and wiring. Rotatable plug in display module provides display of flow rate, temperature, totalized flow, plus diagnostic messages and integrates four push button keypad for ease of configuration. Process temperatures up to +200 °C (+400 °F). Pressure rating to 103 bar (1500 psig) dependent upon process connections. Probe can be field replaced. Sensor is protected to prevent damage if inserted too far into pipe. Optional: - hot tap retractable probe assembly or valve with compression fitting - flow body for 1/2" to 4" pipe sizes - flow conditioning plate for flow bodies 11/2" and higher. Suited for SIL 1 and SIL 2 loops (full FMEDA report available). FE T Y I EGRITY V EL LE A P P L I C AT I O N S • • • • • • • TA2 with sensor with flow body NT SA TA2 with insertion probe Combustion air Digester/Bio-gas Compressed air/gas Vent lines/flare headers Natural gas Hydrogen piping Aeration lines A G E N C Y A P P R O VA L S Agency Approval ATEX FM/CSA ATEX II 2G EEx d II C T6, explosion proof Non Incendive Explosion proof (Groups B, C and D) RosTechnadzor / Russian Authorisation Standards GOST-R Worldwide level and flow solutions P R I N C I P L E O F O P E R AT I O N Thermatel Model TA2 flow transmitter measures mass flow by detecting heat dissipation from a heated surface. The sensor contains two mass balanced elements with precision matched RTD’s. The reference sensor measures the process temperature (up to +200° C [+400° F]); the second RTD measures the temperature of the heated sensor. The power to the heater is varied to maintain a constant temperature difference above the reference temperature. There is an inherent non-linear relationship between power and mass flow. The microprocessor in the TA2 compares the power against the calibration curve and converts the power requirements to the mass flow rate. Temperature is also measured to provide temperature compensation of the mass flow over the operating range of the instrument. flow no flow A D D I T I O N A L F E AT U R E S TEMPERATURE COMPENSATION Thermal flow technology measures the mass flow rate without the need for pressure and temperature correction as required with most gas flow instruments that measure the flow rate at actual conditions. However, changing temperature will change the properties of the gas which effect convective heat transfer. The Model TA2 measures the temperature and automatically corrects the mass flow measurement for changes in gas properties over the entire temperature range of the instrument. TOTALIZER The software totalizer provides a nine-digit display of the total flow in the user’s choice of engineering units. The use of EEPROM for storage of totalized data eliminates the need for backup batteries, and provides maximum safeguard of data in the event of a power interruption. The totalizer can be reset using the display module or HART. SELECTABLE STP CONDITIONS (Normalized conditions) The TA2 directly measures mass flow of the gas at Standard Temperature and Pressure (STP) conditions. Software permits the user to change STP conditions for their own requirements. DIAGNOSTICS Diagnostics is an important aspect of the TA2. The unit has the ability to check the probe status and indicate either normal operation, short or open circuit in the PT 1000, or heater circuit. In order to verify that the calibration and configuration match the original calibration conditions, the user can select a specific signal and compare the TA2 display value against the original calibration certificate. AREA COMPENSATION FOR PIPE SIZE Insertion of the sensor into a pipe reduces the flow area, thus increasing the velocity for a given flow rate. The TA2 automatically compensates the flow measurement based on actual area of the pipe. The user simply enters the size or the area of the pipe, and the instrument automatically compensates the flow measurement for the probe blockage. PROBE INSTALLATION Probes can be provided with a variety of process connections, including threads, flanges, or installation through a compression fitting. The sensor will fit pipe sizes of 1 1⁄2" diameter or larger (2"/DN 50 minimum size with thread connection). The sensor is protected to prevent damage due to “bottoming-out” if inserted too far into a pipe. When using an insertion probe with compression fitting, the user can adjust the position of the sensor in the pipe to obtain the optimum location. Typically, this will be with the bottom of the probe 25 mm (1.0") lower than the center line of the pipe. PORTABLE DISPLAY MODULE A portable display module for configuration and diagnosis of multiple units is available (part number 089-5219-001). This portable module plugs into the electronics in the same manner as the normal display and uses the same software menu. This module permits the user to reduce installation cost by having one display module with keypad for multiple TA2 units. Usage of the display module requires that the housing cover be removed during use and thus may not be useable in hazardous areas. In these cases, the HART option should be utilized. PROBE SIMULATION MODULE The Model TA2 has an optional probe simulation module (part number 089-5220-001). Using this module, the user can disconnect the probe from the electronics and verify the operation of the transmitter electronics against a known standard. FACTORY CALIBRATION AND CONFIGURATION Each TA2 is calibrated at the factory for the type of gas and the specified flow rate. The instrument is configured for the specific application information. The result is an instrument which can be installed and immediately be placed into operation without field setup. AIR EQUIVALENCY Using historic air-gas calibration data, an air equivalency calibration can be performed on select gases. Consult your Magnetrol contact for details and flow ranges. Portable display module 2 A P P L I C AT I O N S COMPRESSED AIR/GASES Measurement of mass flow in different gas lines to determine in plant usage for internal allocation. Advantages: • direct mass flow • high turndown rates • flow totalization • easy installation FLARE LINES Measurement of flow in different sections of flare line. Advantages: • good low flow sensitivity • high turndown • easy removal if cleaning is required BOILER COMBUSTION The TA2 measures the inlet air flow to the boiler. This signal is sent to the DCS where it is used to trim the natural gas flow. Advantages: • mass flow measurement • repeatable flow signal • high rangeability AERATION AIR FLOW Measurement and balance of the flow to each section of the aeration basin in waste water treatment plants. Advantages: • low installation cost • direct mass flow • high reliability Natural Gas NATURAL GAS FLOW The Model TA2 efficiently measures the flow and totalized flow of fuel to furnaces, heaters, or boilers. This data may be used for internal allocation or to report emission rates. Advantages: • direct mass flow in Nm3/h • built in totalizer • easy in setup and operation DIGESTER GAS/BIO-GAS The off gas from a digester contains a mixture of methane and carbon dioxide saturated with moisture. This is a difficult flow measurement due to low flow rate and low pressures. Advantages: • excellent low flow sensitivity • high turndown rates • provides measurement of flow and totalized flow Air To engine or flare Natural Gas or propane 3 DIMENSIONS IN mm (inches) Integral Mount TA2 114 (4.49) A 3/4" NPT or M20 connection (2 entries - one plugged) 99 (3.89) 5.18 (132) 165 (6.49) Optional compression fitting Typical height when compression fitting is used with half coupling or threadolet 3/4" or 1" NPT recommended Consult page 6 for dimension “A” Dimension A: 85 (3.33) without display 99 (3.88) with display A Insertion length Pipe centerline 25 mm (1) Remote Mount TA2 114 (4.49) 3/4" NPT or M20 (2 entries - one plugged) 3/4" NPT or M20 118 (4.63) 70 (2.75) 160 (6.30) 2 holes Ø 10 (0.38) 82 (3.23) 70 (2.75) 76 (3.00) 51 (2.00) 89 (3.50) Insertion length BSP thread / compression fitting Insertion length NPT thread 95 (3.75) 3/4" NPT or M20 transducer cable connector 3/4" S E L E C T I O N D ATA A complete measuring system consists of: 1. 2. 3. 4. 4 Thermatel® TA2 mass flow electronics. Thermatel® TA2 mass flow transmitters require an application report for performing pre-calibration from factory. Ask your magnetrol® contact for assistance when specifying a device. Thermatel® TA2 mass flow insertion probe or Thermatel® TA2 mass flow sensor with flow body. Connecting cable for remote mount Thermatel® TA2 mass flow transmitters Options: - portable display module – order number: 089-5219-001 (for more details see page 2) - probe simulation module – order number: 089-5220-001 (for more details see page 2) - retractable probe assembly (RPA) – for order code see page 10 - valve and compression fitting – order number: 089-5218-001 (for more details see page 10) - duct mounting bracket – order number: 089-7247-001 (for more details see page 4) - compression fittings – for order code see page 6. 1. Order code for Thermatel® TA2 mass flow transmitter BASIC MODEL NUMBER T A 2 Thermatel® TA2 Mass Flow transmitter 2 1 0 INPUT VOLTAGE 24 V DC 240 V AC 120 V AC SIGNAL OUTPUT 1 4-20 mA with HART communication 0 B ACCESSORIES Blind transmitter (can receive the plug in display as future option) Plug in digital display and keypad 1 3 4 MENU LANGUAGE (HART communication is only available in English language) English French German ACTUAL GAS CALIBRATION For TA2 with insertion probe 0 1 2 3 Special. Specify medium separately Air Nitrogen or Oxygen Hydrogen 4 5 6 7 Natural gas Methane Digester gas Propane E F G H Natural gas Methane Digester gas Propane For TA2 with sensor with flow body A B C D Special. Specify medium separately Air Nitrogen or Oxygen Hydrogen AIR EQUIVALENCY CALIBRATION Air equivalency values are available for various gases, consult factory for gases and flow rates. 9 K For TA2 with insertion probe For TA2 with sensor with flow body 3 4 C D MOUNTING/CLASSIFICATION (Consult factory for FM/CSA approvals) Integral, General Purpose (FM/CSA explosion proof) Remote, General Purpose (FM/CSA explosion proof)* Integral, ATEX II 2G EEx d II C T6, explosion proof Remote, ATEX II 2G EEx d II C T6, explosion proof* * Bracket for electronics and probe housing included 1 0 T A 2 1 HOUSING MATERIAL / CABLE ENTRY IP 66, Cast aluminium - M20 x 1,5 cable entry (2 entries - one plugged) IP 66, Cast aluminium - 3/4" NPT cable entry (2 entries - one plugged) complete order code for Thermatel® TA2 Mass Flow transmitter 5 DIMENSIONS IN mm (inches) insertion length insertion length BSP (G1) ø 19 (0,75) insertion length insertion length NPT ø 19 (0,75) ø 19 (0,75) TMR for mounting with compression fitting Process Conn. Size Height A 1" NPT 79 (3.1) ⁄ " NPT 66 (2.6) 34 TMR with threaded connection TMR with flanged connection Compression fitting Teflon ferrules Stainless steel ferrules 011-4719-009 011-4719-007 (6,90 bar maximum) (69 bar maximum) 011-4719-008 011-4719-006 (6,90 bar maximum) (69 bar maximum) min 3 m – max 15 m Connecting cable ELECTRICAL WIRING Supply power: 24 V DC or 240 / 120 V AC Output Shield to ground Shielded twisted pair cable Active or Passive output A- / A+ = active output: power supplied by TA2 P- / P+ = passive output: power supplied by external 24 V DC source Ex 6 Non Ex S E L E C T I O N D ATA 2. Order code for Thermatel® TA2 mass flow insertion probe BASIC MODEL NUMBER T M R Thermatel® TA2 Mass Flow probe A B MATERIALS OF CONSTRUCTION 316/316L (1.4401/14404) stainless steel Hastelloy C (2.4819) - not available with compression fitting PROCESS CONNECTION 0 0 0 Compression fitting - min 11 cm insertion length (compression fittings are not included, for proper order numbers – see page 6). Only available with 316/316L (1.4401/1.4404). Consult factory for Hastelloy C (2.4819) Threaded 1 1 0 3/4" NPT - default selection in combination with a retractable probe assembly (RPA) see page 6 2 1 0 1" NPT 2 2 0 1" BSP (G1) 2 2 3 3 4 4 ANSI flanges 3 0 1" 4 0 1" 3 0 1 1/2" 4 0 1 1/2" 3 0 2" 4 0 2" 150 300 150 300 150 300 lbs lbs lbs lbs lbs lbs B B C C D D EN/DIN flanges A 0 DN 25 B 0 DN 25 A 0 DN 40 B 0 DN 40 A 0 DN 50 B 0 DN 50 PN PN PN PN PN PN 16 25/40 16 25/40 16 25/40 - RF RF RF RF RF RF flange flange flange flange flange flange EN EN EN EN EN EN 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 Type Type Type Type Type Type A A A A A A INSERTION LENGTH - consider process connections Min probe length 0 0 7 0 0 9 7 cm (2,6") fix length 9 cm (3,5") fix length - for NPT threaded - for BSP threaded Selectable probe length - specify per 1 cm (0,39") increments 0 0 0 2 T M R 0 0 1 2 5 9 1 5 3 min. 9 cm (3,5") min. 11 cm (4,5") min. 25 cm (10") max. 253 cm (99,9") - for for for for NPT threaded and flanged BSP threaded and compression fitting use with RPA (Retractable Probe Assembly) all probe connections complete order code for Thermatel® TA2 mass flow insertion probe 3. Order code for connecting cable remote mount Thermatel® TA2 mass flow transmitter 0 3 7 – 3 3 1 4 0 0 9 – 8 2 7 0 General purpose connecting cable - 8 wire shielded instrument cable ATEX explosion proof connecting cable - 8 wire shielded instrument cable CABLE LENGTH - specify per 1 m (3.28') increments 0 0 3 min 3 m (10') length 0 1 5 max 15 m (50') length 0 complete order code for connecting cable 7 DIMENSIONS IN mm (inches) A A B B L1 L L1 L Flanged flow body Threaded flow body Length (L) Code Size 0 1/2" 1 3/4" 2 1" 3 11/2" 4 L1 With Flow Without Flow Conditioning Conditioning mm (inches) mm (inches) 203 (8)➀ 286 (11.25)➀ 381 (15)➀ — — — Overall Height (B) Height to Centerline (A) NPT-F Flange mm (inches) mm (inches) mm (inches) With Flow Conditioning mm (inches) Without Flow Conditioning mm (inches) 127 (5)➀ — 203 (8.0) 221 (8.7) 248 (9.75) — 203 (8.0) 221 (8.7) 251 (9.9) 190 (7.5)➀ 254 (10)➀ — 203 (8.0) 221 (8.7) 257 (10.1) 495 (19.5) 191 (7.5) 305 (12) 95 (3.75) 212 (8.35) 236 (9.3) 276 (10.85) 2" 660 (26) 191 (7.5) 406 (16) 95 (3.75) 235 (9.25) 264 (10.4) 311 (12.25) 5 3" 991 (39) 254 (10) 610 (24) 127 (5) 235 (9.25) N/A 330 (13.0) 6 4" 1321 (52) 305 (12) 914 (36) 152 (6) 235 (9.25) N/A 349 (13.75) ➀ The upstream length in pipe sizes < 1 1/2" dia. is sufficient to create the flow conditioning effect without need for a flow conditioning plate. Flow body sizing The following table is a general guide on flow sizing. Contact your Magnetrol contact for specific application information. Max flow rate Code 8 Size ⁄2" 0 1 1 3 2 1" 3 11⁄2" 4 2" 5 3" 6 4" ⁄4" Air, N2, O2 Natural Gas, Methane Digester Gas Propane Hydrogen CO2, Argon 110 NM3/h 65 SCFM 76 NM3/h 45 SCFM 42 NM3/h 25 SCFM 51 NM3/h 30 SCFM 27 NM3/h 15 SCFM 105 NM3/h 60 SCFM 204 NM3/h 120 SCFM 340 NM3/h 200 SCFM 140 NM3/h 85 SCFM 238 NM3/h 140 SCFM 76 NM3/h 45 SCFM 127 NM3/h 75 SCFM 93 NM3/h 55 SCFM 161 NM3/h 95 SCFM 52 NM3/h 30 SCFM 85 NM3/h 50 SCFM 190 NM3/h 110 SCFM 320 NM3/h 190 SCFM 833 NM3/h 490 SCFM 580 NM3/h 340 SCFM 310 NM3/h 180 SCFM 395 NM3/h 230 SCFM 208 NM3/h 120 SCFM 790 NM3/h 465 SCFM 1220 NM3/h 715 SCFM 3000 NM3/h 1765 SCFM 5490 NM3/h 3230 SCFM 855 NM3/h 505 SCFM 2110 NM3/h 1240 SCFM 3845 NM3/h 2260 SCFM 480 NM3/h 280 SCFM 1180 NM3/h 695 SCFM 2145 NM3/h 1265 SCFM 600 NM3/h 350 SCFM 1470 NM3/h 860 SCFM 2675 NM3/h 1575 SCFM 332 NM3/h 195 SCFM 812 NM3/h 475 SCFM 1478 NM3/h 865 SCFM 1155 NM3/h 680 SCFM 2855 NM3/h 1680 SCFM 5210 NM3/h 3060 SCFM S E L E C T I O N D ATA 2. Order code for Thermatel® TA2 sensor with flow body BASIC MODEL NUMBER T F T Thermatel® TA2 sensor with mass flow body MATERIALS OF CONSTRUCTION A 1 316/316L (1.4401/1.4404) stainless steel body and sensor Carbon steel body / stainless steel sensor THREADED FLOW BODY - ø size and connection 1/2" NPT 0 1 3/4" 1 1 NPT 2 1 1" NPT 3 1 11/2" NPT 2" NPT 4 1 FLANGED FLOW BODY - ø size and connection 1/2" 150 lbs RF flange 0 3 3/4" 1 3 150 lbs RF flange 2 3 1" 150 lbs RF flange 3 3 11/2" 150 lbs RF flange 4 3 2" 150 lbs RF flange 5 3 3" 150 lbs RF flange 6 3 4" 150 lbs RF flange 0 1 T F T Accessoires None Stainless steel flow conditioning plate - for flow body sizes ≥ 11/2" 0 0 0 complete order code for Thermatel® TA2 sensor with flow body Flow Flow conditioning plate 9 S E L E C T I O N D ATA 4. Order code for retractable probe assembly BASIC MODEL NUMBER R P A Retractable probe assembly DESIGN TYPE E F Low pressure - up to 5,5 bar (80 psi) High pressure - up to 300 lbs / service MATERIALS OF CONSTRUCTION 1 Carbon steel with 316 SST (1.4401) seal gland 4 316 SST (1.4401) PROCESS CONNECTION 0 1 2 1 1/2" NPT 1 1/2" - 150 lbs RF flange 1 1/2" - 300 lbs RF flange 0 1 2 BALL VALVE No ball valve supplied Carbon steel ball valve Stainless steel ball valve – not available for RPA-E1 – select material code 1 – select material code 4 PROBE LENGTH 0 2 5 min 25 cm (10") 2 5 3 max 253 cm (99,9") complete order code for retractable probe assembly R P A High Pressure RPA Hot Tap retractable probe assembly 70 (1000) Pressure bar (psig) 60 (900) 55 (800) 50 (700) 40 (600) 35 (500) 30 (400) 20 (300) Low Pressure RPA max. 5,5 bar (80 psig) 15 (200) High Pressure 0 40 (100) 95 (200) 150 (300) 205 (400) Temperature °C (°F) 150 lb. flange Valve with compression fitting Threaded or 300 lb. flange Order code: 089-5218-001 10 T R A N S M I T T E R S P E C I F I C AT I O N S FUNCTIONAL/PHYSICAL Description Power supply Power consumption Active Signal Output Passive Resolution Analog Display Calibration Damping Diagnostic Alarm User Interface Display Displayed values Menu Language Housing Material Approvals SIL (Safety Integrity Level) Net and gross weight Specification 19 – 29 V DC 204 – 260 V AC, 50-60 Hz 102 – 132 V AC, 50-60 Hz 6W–9VA 4-20 mA isolated (3,8 – 20,5 mA useable as per NAMUR NE 43) max 1000 Ω loop resistance 4-20 mA isolated (3,8 – 20,5 mA useable as per NAMUR NE 43) max loop resistance depending power supply 0,01 mA 0,01 Nm/s Pre-calibrated from factory - NIST traceable Adjustable 0-15 s time constant Adjustable 3,6 mA, 22 mA or Hold 4-button keypad and/or HART® communicator 2-line x 16-character LCD Flow (eg. Nm3/h, Nl/h) and/or mass flow (eg. kg/h) and/or temperature (°C/°F) and/or loop current (mA) and/or totalized flow (eg. Nm3/h, Nl/h) English, French or German IP 66, Aluminium A 356 (< 0,2 % copper) dual compartment ATEX II 2G EEx d IIC T6, explosion proof FM, explosion proof (Groups B, C and D) and non incendive CSA, explosion proof (Groups B, C and D) RosTechnadzor/GOST-R, Russian authorisation standards Functional safety to SIL1/SIL2 in accordance to IEC 61508 – SFF: 69 %. Full FMEDA report and declaration sheets available at request. 3,3 kg (7.3 lbs) net; 4,0 kg (8.8 lbs) gross (amplifier with 25 cm threaded probe) PERFORMANCE Description Turn down ratio Flow range Max Min Linearity Accuracy Flow Temperature Repeatability Response time Remote electronics Ambient temperature Operating temp. effect Humidity Electromagnetic Compatibility Specification 100:1 typical (depending upon calibration) 0,13 - 200 Nm/s (25 - 40,000 SFPM) reference of air at STP conditions 0,13 - 2,5 Nm/s (25 - 500 SFPM) reference of air at STP conditions Included in flow accuracy ± 1 % of reading + 0,5 % of calibrated full scale ± 1 °C (2 °F) ± 0,5 % of reading Time constant of 1 to 2 s Max 15 m (50') away from probe - for longer lengths, consult factory -40 °C up to +70 °C (-40 °F up to +160 °F) – display not readable below -20 °C (-4 °F) ± 0,04 % per °C 99 %, non-condensing Meets CE requirements (EN-61000-6-4, EN 61000-6-2) and are in compliance with EMC directive 89/336/EEC PROBE SPECIFICATIONS Description Insertion probe Sensor with flow body Materials – wetted parts 316/316L (1.4401/1.4404) or Hastelloy C (2.4819) Sensor: 316/316L (1.4401/1.4404) Flow body: stainless steel or carbon steel Mounting Threaded, compression fitting, ANSI-DIN flanged or with Retractable probe assembly Threaded or flanged Probe length Max. process temperature Max pressure rating From 70 mm up to 2530 mm (2.6" up to 100") Flow body sizes from 1/2" up to 4" -45 °C up to +120 °C Integral electronics: -45 °C up to +200 °C with 100 mm (4") longer probe serving as heat extension Remote electronics: -45 °C up to +200 °C 103 bar (1500 psi) @ +20 °C (+70 °F) 95 bar (1375 psi) @ +200 °C (+400 °F) – direct insertion 75 bar (1100 psi) @ +200 °C (+400 °F) – with flow body 11 DIMENSIONS IN mm (inches) Safety cable Retaining bar Adjustment rods S Dimension Threaded connection Flanged connection Seal nut Seal nut 1 1/2" NPT Adjustment nuts S Ball Valve Dimensions* Size V 11⁄2" NPT 112 (4.4) 11⁄2" 150# flange 165 (6.5) 11⁄2" 300# flange 190 (7.5) V X Ball valve T 102 (4.00) 127 (5.00) Customer connection Vessel wall Y Ball valve *Dimension of ball valve if supplied by the factory. V X Vessel wall Hot tap Model RPA-E402-XXX Customer connection Y 200 (8) minimum probe length: S + X + Y Typical 1" NPT customer supplied Hot tap Model RPA-FX12-XXX 1" NPT ball valve with compression fitting (TFE ferrules) (089-5218-001) minimum probe length: T = 2 (X + Y) Duct mounting bracket 3/4" NPT connection Ø 152,4 (6.00) Duct mounting bracket with 3⁄4" NPT part number 089-7247-001 or 089-7247-002 (includes hardware) QUALITY ASSURANCE - ISO 9001:2000 THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS. OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001:2000 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE. :2000 PRODUCT WARRANTY ALL MAGNETROL ELECTRONIC AND ULTRASONIC LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE FULL YEAR FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN TRANSPORTATION. MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME MAGNETROL PRODUCTS. ® UNDER RESERVE OF MODIFICATIONS Heikensstraat 6, 9240 Zele, België Tel. +32 (0)52.45.11.11 • Fax. +32 (0)52.45.09.93 • E-Mail: [email protected] DEUTSCHLAND Alte Ziegelei 2-4, D-51491 Overath Tel. 02204 / 9536-0 • Fax. 02204 / 9536-53 • E-Mail: [email protected] FRANCE 40 - 42, rue Gabriel Péri, 95130 Le Plessis Bouchard Tél. 01.34.44.26.10 • Fax. 01.34.44.26.06 • E-Mail: [email protected] ITALIA Via Arese 12, I-20159 Milano Tel. (02) 607.22.98 (R.A.) • Fax. (02) 668.66.52 • E-Mail: [email protected] UNITED KINGDOM Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL Tel. (01444) 871313 • Fax (01444) 871317 • E-Mail: [email protected] INDIA E-22, Anand Niketan, New Delhi - 110 021 Tel. 91 (11) 41661840 • Fax 91 (11) 41661843 • E-Mail: [email protected] www.magnetrol.com BENELUX BULLETIN N°: EFFECTIVE: SUPERSEDES: OUR NEAREST REPRESENTATIVE BE 54-130.6 JULY 2006 May 2006