EZ Modulevel - Magnetrol International

EZ Modulevel®
Displacer operated
level transmitter
®
DESCRIPTION
EZ Modulevel are electronic 24 V DC, loop powered level
transmitters utilizing Magnetrolʼs buoyancy principle to detect
and convert liquid level changes into a stable 4-20 mA output
signal.
The linkage between the level sensing element and output
electronics greatly simplifies mechanical design and construction. The in-line vertical design of the transmitter
reduces instrument weight and the effects of process vibration on electronic circuitry components while simplifying
installation.
For continuous level or liquid-liquid interface
F E AT U R E S
• Operation functions include:
•
•
•
•
•
•
- interface measurement and detection
- continuous level measurement
- density measurement
Easy bench calibration via Hart® terminal, AMS® protocol or PACTware®
- full calibration (dry set point, 4-20 mA by %)
- setting of Specific Gravity
- signal damping
- error signal.
Two-wire, intrinsically safe loop powered level transmitter.
360° rotatable housing can be dismantled without
depressurizing the vessel.
Integral or remote electronics.
Special options, materials and custom engineered features.
Suited for SIL 1 and SIL 2 loops (full FMEDA report
available).
FE T Y I
NT
SA
EGRITY
A G E N C Y A P P R O VA L S
Agency
Approval
V EL
LE
ATEX
➀
FM/CSA
A P P L I C AT I O N S
MEDIA: liquids with a S.G. as low as 0,23 up to 2,2 and interfaces with a density difference of minimum 0,10.
VESSELS: most process vessels up to 315 °C (600 °F) process temperature and pressures up to 355 bar (5150 psi) or
storage vessels e.g:
- feedwater heaters
- condensate Drip Pots
- scrubbers
- separators
- receivers
- flash tanks
- knock out drums
- boilers
➁
LRS
RosTech/FSTS
➀
GOST-K/GGTN-K
➀
➁
II 1G EEx ia II C T6, intrinsically safe
II 1/2G EEx d II C T6, explosion proof
non incendive, explosion proof
and intrinsically safe
Lloyds Register of Shipment
(marine applications)
Russian Authorisation Standards
Cast aluminium housing is available for intrinsically safe
units only. Not valid for FM/CSA
Consult factory for proper partnumbers.
Worldwide level and flow solutions
P R I N C I P L E O F O P E R AT I O N
Liquid level change acts upon the range spring supported
displacer causing vertical motion of a core within a linear
variable differential transformer (LVDT).
The enclosing tube acts as a static isolation barrier
between the LVDT and the process media.
As core position changes with liquid level, voltages are
induced in the secondary windings of the LVDT.
These signals are processed in the electronic circuitry and
used to control the current in the 4-20 mA output
current loop.
LVDT
Moving LVDT Core
Enclosing tube
Range spring
Displacer
External cage
MOUNTING
-40°C to +70°C (-40°F to 160°F)
Max 355 bar (5150 psi)
Oil
Water
Max 315 °C (600 °F) - non steam
Max 260 °C (500 °F) - steam
2
S E L E C T I O N D ATA
top mounting
steam applications
max 600 lbs
non-steam
applications
eg. hydrocarbon
from 900 lbs
to 2500 lbs
cage side/bottom
cage side/side
CS
E81
CS
E83
CS
E85
SST
SST
SST
E82
E84
E86
C O N F I G U R AT I O N S
E83/E84
Side/Bottom
E81/E82
Flanged Top
E85/E86
Side/Side
EXPEDITE SHIP PLAN (ESP)
Several EZ Modulevel devices are available for quick shipment, within max. 3 weeks after factory receipt of purchase order,
through the Expedite Ship Plan (ESP).
Models covered by ESP service are conveniently grey coded in the selection data charts.
To take advantage of ESP, simply match the grey coded model number codes (standard dimensions apply).
ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume
orders, as well as other products and options.
S E L E C T I O N D ATA - O p t i o n s :
1. Adjustable displacer hanger for top mounted units, cable length 2,5 m (8'). Order code 032-3110-004 – required when
distance between the top of the displacer and the flange face is > dimension A (see page 10 & 11) + 60 mm (2.36").
2. Calibraton stand for bench calibration, order code 031-6107-001.
3. HAND HELD communicator, consult factory.
4. Free of charge: Magnetrol master C.D. with EZ Modulevel DTM (PACTware®). Order code: 090-BE59-200 (included in each
order).
3
S E L E C T I O N D ATA – n o n s t e a m a p p l i c a t i o n s ( m a x 6 0 0 l b s )
A complete measuring system consists of:
1. One order code for a complete standard EZ Modulevel® transmitter.
Order code for modified models/adders: put an "X" in front of the closest matching order code and specify the modification/adders separately.
X = material certification EN 10204 / DIN 50049-3.1.B
e.g: XE85-KQ3A-ESD
Aluminium housing
2. Options - see page 3
1. Order code for Standard EZ Modulevel® transmitter – non steam applications
BASIC MODEL NUMBER
E
E
E
E
E
E
8
8
8
8
8
8
1
2
3
4
5
6
top mounted EZ Modulevel
top mounted EZ Modulevel
EZ Modulevel with side/bottom cage
EZ Modulevel with side/bottom cage
EZ Modulevel with side/side cage
EZ Modulevel with side/side cage
- Carbon steel construction
- Stainless steel construction
- Carbon steel construction
- Stainless steel construction
- Carbon steel construction
- Stainless steel construction
SPECIFIC GRAVITY AND PROCESS TEMPERATURE (consult factory for interface applications)
mounting
integral
integral
integral
integral
remote
max. temp.
150° C
200° C
230°C
290°C
315°C
J
A
K
L
M
B
D
N
C
Q
E
P
F
PROCESS CONNECTION
a. For top mounted connection type
E81/E82 - ANSI HEAD Flange rating
600 lbs
150 lbs
300 lbs
Size
RF
RF
RF
RJ
G3
G4
G5
G6
3"
H3
H4
H5
H6
4"
K3
K4
K5
K6
6"
b. For external cage models
0.23 - 0.54 specific gravity
R
0.55 - 1.09 specific gravity
T
1.10 - 2.20 specific gravity
E81/E82 - DIN / EN 1092-1 HEAD Flange rating
Type B1 Type B1 Type B2 Type B2
Size
PN 16 PN 25/40 PN 63
PN 100
EA
FA
GA
EB
FB
GB
ED
FD
GD
EE
FE
GE
DN 80
DN 100
DN 150
E83 ... E86 - ANSI Flange/Cage rating
E83 ... E86 - DIN / EN 1092-1 Flange rating
600 lbs
300 lbs
Type B1 Type B1 Type B2 Type B2
Size
Size
RF
PN 16 PN 25/40 PN 63
PN 100
RF
RJ
P3
P4
P5
P6
11/2" flanged
DN 40
Q3
Q4
Q5
Q6
2" flanged
CA
CB
CD
CE
flanged
R3
R4
R5
11/2" NPT-F
S3
S4
S5
2" NPT-F
DN 50
T3
T4
T5
11/2" S.W.
DA
DB
DD
DE
flanged
U3
U4
U5
2" S.W.
150 lbs
RF
LEVEL RANGE
356
813
14
32
A
B
1219
48
C
1524
60
D
Blind
ESD
ESA
EZA
4
E
2134
84
F
2438
96
G
2743
108
H
3048
120
I
mm
inches
code
TRANSMITTER – ELECTRONICS
Standard codes apply for cast iron housing - use "X" description for stainless steel or cast
aluminium housing
INTEGRAL MOUNT ELECTRONICS
Max 290 °C (All except Q, R, T)
E 8
1829
72
with meter
Analog Digital
ESI
ESJ
ESG
ES9
EZG
–
24 V DC amplifier head
Process Temperature (codes as per digit 4)
with meter
Local meter
Output
Blind
Analog Digital
& Safety approvals
RSQ
RST
RSZ 4 - 20 mA with HART®, intrinsically safe
RSW
RSX
RS4 4 - 20 mA with HART®, explosion proof
RZW
RZX
–
4 - 20 mA, explosion proof
REMOTE ELECTRONICS
Max 315 °C (Q, R or T)
complete order code for EZ Modulevel transmitter –
non steam applications
S E L E C T I O N D ATA – s t e a m a p p l i c a t i o n s ( m a x 6 0 0 l b s )
A complete measuring system consists of:
1. One order code for a complete standard EZ Modulevel® transmitter.
Order code for modified models/adders: put an "X" in front of the closest matching order code and specify the modification/adders separately.
X = material certification EN 10204 / DIN 50049-3.1.B
e.g: XE85-KQ3A-ESD
Aluminium housing
2. Options - see page 3
1. Order code for Standard EZ Modulevel® transmitter – steam applications
BASIC MODEL NUMBER
E
E
E
E
E
E
8
8
8
8
8
8
1
2
3
4
5
6
top mounted EZ Modulevel
top mounted EZ Modulevel
EZ Modulevel with side/bottom cage
EZ Modulevel with side/bottom cage
EZ Modulevel with side/side cage
EZ Modulevel with side/side cage
- Carbon steel construction
- Stainless steel construction
- Carbon steel construction
- Stainless steel construction
- Carbon steel construction
- Stainless steel construction
SPECIFIC GRAVITY AND PROCESS TEMPERATURE (consult factory for interface applications)
mounting
integral
integral
integral
remote
max. temp.
150°C
200°C
230°C
260°C
J
A
K
M
B
L
Q
N
C
PROCESS CONNECTION
a. For top mounted connection type
0.23 - 0.54 specific gravity
R
P
0.55 - 1.09 specific gravity
T
E81/E82 - ANSI HEAD Flange rating
600 lbs
300 lbs
Size
RF
RF
RJ
G3
G4
G5
G6
3"
H3
H4
H5
H6
4"
K3
K4
K5
K6
6"
150 lbs
RF
b. For external cage models
1.10 - 2.20 specific gravity
E81/E82 - DIN / EN 1092-1 HEAD Flange rating
Type B1 Type B1 Type B2 Type B2
Size
PN 16 PN 25/40 PN 63
PN 100
EA
FA
GA
EB
FB
GB
ED
FD
GD
EE
FE
GE
DN 80
DN 100
DN 150
E83 ... E86 - ANSI Flange/Cage rating
E83 ... E86 - DIN / EN 1092-1 Flange rating
600 lbs
300 lbs
Type B1 Type B1 Type B2 Type B2
Size
Size
RF
PN 16 PN 25/40 PN 63
PN 100
RF
RJ
P3
P4
P5
P6
11/2" flanged
DN 40
Q3
Q4
Q5
Q6
2" flanged
CA
CB
CD
CE
flanged
R3
R4
R5
11/2" NPT-F
S3
S4
S5
2" NPT-F
DN 50
T3
T4
T5
11/2" S.W.
DA
DB
DD
DE
flanged
U3
U4
U5
2" S.W.
150 lbs
RF
LEVEL RANGE
356
813
14
32
A
B
1219
48
C
1524
60
D
1829
72
F
2438
96
G
2743
108
3048
120
H
I
mm
inches
code
TRANSMITTER – ELECTRONICS
Standard codes apply for cast iron housing - use "X" description for stainless steel or cast
aluminium housing
INTEGRAL MOUNT ELECTRONICS
Max +150 °C
(J, K or L)
with meter
Blind
Analog Digital
ESD
ESI
ESJ
ESA
ESG
ES9
EZA
EZG
–
E 8
E
2134
84
Max +230 °C
(A, B, C, M, N or P)
with meter
Blind
Analog Digital
ESH
ESK
ES8
ESE
ESF
ES7
EZE
EZF
–
REMOTE ELECTRONICS
Max +260 °C
(Q, R or T)
with meter
Blind
Analog Digital
RSQ
RST
RSZ
RSW
RSX
RS4
RZW
RZX
–
24 V DC amplifier head
Local meter
Process Temperature
(codes as per digit 4)
Output
& Safety approvals
4 - 20 mA with HART®, intrinsically safe
4 - 20 mA with HART®, explosion proof
4 - 20 mA, explosion proof
complete order code for EZ Modulevel transmitter –
steam applications
5
S E L E C T I O N D ATA – n o n s t e a m a p p l i c a t i o n s ( f r o m 9 0 0 l b s t o 2 5 0 0 l b s )
A complete measuring system consists of:
1. One order code for a complete standard EZ Modulevel® transmitter.
Order code for modified models/adders: put an "X" in front of the closest matching order code and specify the modification/adders separately.
X = Material certification EN 10204 / DIN 50049-3.1.B
e.g: XE85-KQ8A-ESD
Aluminium housing
2. Options - see page 3
1. Order code for Standard EZ Modulevel® transmitter – non steam applications / high pressure
BASIC MODEL NUMBER
E
E
E
E
E
E
8
8
8
8
8
8
1
2
3
4
5
6
top mounted EZ Modulevel
top mounted EZ Modulevel
EZ Modulevel with side/bottom cage
EZ Modulevel with side/bottom cage
EZ Modulevel with side/side cage
EZ Modulevel with side/side cage
- Carbon steel construction
- Stainless steel construction
- Carbon steel construction
- Stainless steel construction
- Carbon steel construction
- Stainless steel construction
SPECIFIC GRAVITY AND PROCESS TEMPERATURE (consult factory for interface applications)
mounting
integral
integral
integral
integral
remote
max. temp.
150° C
200° C
230° C
290°C
315° C
K
B
N
E
R
PROCESS CONNECTION (for DIN flanges consult factory)
a. For top mounted connection type (E81, E82) - head flange rating
900 lbs RJ
1500 lbs RJ
2500 lbs RJ
G7
–
H7
–
H8
K7
H9
K8
b. For external cage models (E83, ... E86) - ANSI rating
K9
900 lbs RJ
1500 lbs RJ
2500 lbs RJ
900 lbs
1500 lbs
2500 lbs
P7
Q7
P8
Q8
R7
S7
T7
U7
R8
S8
T8
U8
LEVEL RANGE (consult factory for longer level range)
356
813
1219
1524
mm
14
32
48
60
inches
A
B
C
D
P9
Q9
R9
S9
T9
U9
0.55 - 1.09 specific gravity
Type
3" size
size
4" size
6" size
Flange rating
connection
1 1/2" ANSI Flanges
2" ANSI Flanges
Cage rating
connection
1 1/2" NPT-F
2" NPT-F
1 1/2" Socket Weld
2" Socket Weld
code
TRANSMITTER – ELECTRONICS
Standard codes apply for cast iron housing - use "X" description for stainless steel or
cast aluminium housing
INTEGRAL MOUNT ELECTRONICS
Max 290 °C (K, B, N or E)
Blind
ESD
ESA
EZA
E 8
6
with meter
Analog Digital
ESI
ESJ
ESG
ES9
EZG
–
24 V DC amplifier head
Process Temperature (codes as per digit 4)
with meter
Local meter
Output
Blind
Analog Digital
& Safety approvals
RSQ
RST
RSZ 4 - 20 mA with HART®, intrinsically safe
RSW
RSX
RS4 4 - 20 mA with HART®, explosion proof
RZW
RZX
–
4 - 20 mA, explosion proof
REMOTE ELECTRONICS
Max 315 °C (R only)
complete order code for EZ Modulevel transmitter –
non steam applications / high pressure
S E L E C T I O N D ATA – s t e a m a p p l i c a t i o n s ( f r o m 9 0 0 l b s t o 2 5 0 0 l b s )
A complete measuring system consists of:
1. One order code for a complete standard EZ Modulevel® transmitter.
Order code for modified models/adders: put an "X" in front of the closest matching order code and specify the modification/adders separately.
X = material certification EN 10204 / DIN 50049-3.1.B
e.g: XE85-KQ8A-ESD
Aluminium housing
2. Options - see page 3
1. Order code for Standard EZ Modulevel® transmitter – steam applications / high pressure
BASIC MODEL NUMBER
E
E
E
E
E
E
8
8
8
8
8
8
1
2
3
4
5
6
top mounted EZ Modulevel
top mounted EZ Modulevel
EZ Modulevel with side/bottom cage
EZ Modulevel with side/bottom cage
EZ Modulevel with side/side cage
EZ Modulevel with side/side cage
- Carbon steel construction
- Stainless steel construction
- Carbon steel construction
- Stainless steel construction
- Carbon steel construction
- Stainless steel construction
SPECIFIC GRAVITY AND PROCESS TEMPERATURE (consult factory for interface applications)
mounting
integral
integral
integral
remote
max. temp.
150° C
200° C
230° C
260° C
K
B
N
R
0.55 - 1.09 specific gravity
PROCESS CONNECTION (for DIN flanges consult factory)
a. For top mounted connection type (E81, E82) - head flange rating
900 lbs RJ
1500 lbs RJ
2500 lbs RJ
K7
K8
K9
G7
–
H7
–
H8
H9
b. For external cage models (E83, ... E86) - ANSI rating
1500 lbs RJ
2500 lbs RJ
900 lbs
1500 lbs
2500 lbs
P8
Q8
R7
S7
T7
U7
R8
S8
T8
U8
3" size
size
4" size
6" size
900 lbs RJ
P7
Q7
Type
P9
Q9
Flange rating
Cage rating
R9
S9
T9
U9
connection
1 1/2" ANSI Flanges
2" ANSI Flanges
connection
1 1/2" NPT-F
2" NPT-F
1 1/2" Socket Weld
2" Socket Weld
LEVEL RANGE (consult factory for longer level range)
356
14
A
813
32
1219
48
B
C
mm
inches
1524
60
code
D
TRANSMITTER – ELECTRONICS
Standard codes apply for cast iron housing - use "X" description for stainless steel or cast
aluminium housing
INTEGRAL MOUNT ELECTRONICS
Max +150 °C
(K only)
with meter
Blind
Analog Digital
ESD
ESA
EZA
E 8
ESI
ESG
EZG
ESJ
ES9
–
Max +230 °C
(B or N)
with meter
Blind
Analog Digital
ESH
ESE
EZE
ESK
ESF
EZF
ES8
ES7
–
REMOTE ELECTRONICS
Max +260 °C
(R only)
with meter
Blind
Analog Digital
RSQ
RSW
RZW
RST
RSX
RZX
RSZ
RS4
–
24 V DC amplifier head
Local meter
Process Temperature
(codes as per digit 4)
Output
& Safety approvals
4 - 20 mA with HART®, intrinsically safe
4 - 20 mA with HART®, explosion proof
4 - 20 mA, explosion proof
complete order code for EZ Modulevel transmitter –
steam applications / high pressure
7
O P E R AT I N G T E M P E R AT U R E S
The following charts lists combinations of process and ambient temperatures that should not be exceeded, with standard
instruments
Non-steam applications
350
Process temperature °C
300
250
200
150
100
50
0
30
35
40
45
50
55
Ambient temp. °C
60
65
70
75
60
65
70
75
Steam applications
Process temperature °C
350
300
250
200
150
100
50
0
30
35
40
50
45
55
Ambient temp. °C
Digit 4 = J/K/L
Digit 4 = D/E/F
Digit 4 = Q/R/T
Digit 4 = A/B/C
Digit 4 = M/N/P
ELECTRICAL WIRING
Hazardous
area
Safe area
I.S.
0%
100 %
AMS®
FDT/PACTware®
8
P H Y S I C A L / E L E C T R I C A L S P E C I F I C AT I O N S
Description
Power (at terminals)
Signal output
Damping
Diagnostic alarm
User interface
Display
Cage materials
4 – 20 mA (direct / reverse action)
EZ Modulevel without Hart®
4 – 20 mA (direct / reverse action)
356 mm up to 3048 mm (14" up to 120") (other ranges at request)
Loop resistance
Wetted materials
ATEX intrinsically safe: 12 to 28,4 V DC (@ 94 mA)
ATEX explosion proof / Non Ex: 12 to 36 V DC
3,8 to 20,5 mA usable (meets NAMUR
NE 43) with Hart® and AMS® supported
Span
Housing material
EZ Modulevel with Hart®
Spring
Displacer
Approvals
SIL (Safety Integrity Level)
Electrical data
Equivalent data
Net and gross weight
600 Ohm at 24 V DC
Max 545 Ohm when used in combination
with 22 mA error signal
480 Ohm at 24 V DC
3,6 mA or 22 mA
none
0 to 60 s
none
Zero/span and error LEDʼs
3-button keypad and/or HART® / AMS®
PACTware®
External explosion proof potentiometers for
zero and span
None (blind), or with local analog or
None (blind), or with analog meter
digital meter
IP 66, polyester coated cast iron - 1 x 1" NPT cable entry
IP 66, stainless steel - 1 x M20 x 1,5 cable entry
IP 66, polyester coated cast aluminium - 2 x M20 x 1,5 cable entries (one plugged off)
Inconel (other materials at request)
316/316L SST (1.4401/1.4404) or 304 SST (1.4301)
Carbon steel or 316/316L SST (1.4401/1.4404) (other materials at request)
ATEX II 1G EEx ia II C T6, intrinsically safe
ATEX II 1/2G EEx d II C T6, explosion proof
FM/CSA/SAA, explosion proof
GOST-K/GGTN-K – ROSTECH/FSTS: Russian Authorisation Standards
LRS, Lloyds Register of Shipment (marine applications)
Other approvals are available, consult factory
Functional safety to SIL 1 / SIL 2 in accordance to IEC 61508 - SFF 66,5 %.
– full FMEDA reports and declaration sheets available at request.
Ui = 28,4 V; Ii = 94 mA; Pi = 0,68 W
Ci = 5 nF; Li = 800 µH
14 kg (31 lbs) (cast iron housing with meter) - integral unit
6,3 kg (13,80 lbs) (cast aluminium housing with meter) - integral unit
15 kg (33 lbs) (stainless steel housing with meter) - integral unit
PERFORMANCE
Description
Specifications
Resolution
0,05 % of range ± 1 digit
Linearity
Accuracy
Repeatability
Response time
Sampling rate
Ambient temperature
Process temperature
Process pressure
Max. ambient temp. effect
Density range
Humidity
Electromagnetic compatibility
➀
± 0,25 % of full span for level measurement
0,5 %
± 0,20 % of full span
Less than 1s (electronics)
15 times / s (digital meter: 1.33 / s)
-40 °C to +70 °C (-40 °F to +160 °F)
-30 °C to +315 °C (+260 °C for steam) (-20 °F to +500 °F (+600 °F for steam)➀
Max. temp. needs to be derated in case of higher ambient temperature.
For lower process temperature – use Stainless steel constructions.
Max 355 bar (5150 psi)
Flanged models are downrated to the design pressure of the selected flange.
< 0,056 % / °C (< 0,031 % / °F)
Min 0,23 S.G. – Max 2,20 S.G.
0-99 %, non condensing
Meets CE requirements (EN-50081-2, EN 50082-2)
For E82, E84 and E86 (SST units): -40 °C (-40 °F) to +315 °C (+500 °F) [+260 °C (+600 °F) for steam]
9
DIMENSIONS in mm (inches)
Top Mounted
E81/E82 - J/K/L
Side/bottom cage
E83/E84 - J/K/L
273
(10.75)
273
(10.75)
367 (14.45)
cast iron: 1 x 1" NPT
stainless steel:
1 x M20 x 1,5
367 (14.45)
cast aluminium: 2 x M20 x 1,5
(one entry plugged off)
A
A
Level
Range
Level
Range
133 (5.24)
C
B
Side/bottom cage
E83/E84 - J/K/L
Side/side cage
E85/E86 - J/K/L
273
(10.75)
Side/side cage
E85/E86 - J/K/L
273
(10.75)
273
(10.75)
367 (14.45)
367 (14.45)
367 (14.45)
A
A
Level
Range
Level
Range
133 (5.24)
133 (5.24)
1" NPT-F drain
(plug not supplied)
B
B
A
Level
Range
133 (5.24)
1" NPT-F drain
(plug not supplied)
B
T E M P E R AT U R E E X T E N S I O N S
Models E8x-A/B/C
Models E8x-M/N/P
Models E8x-D/E/F
Models E8x-Q/R/T
485 (19.1)
469
(18.45)
10
570
(22.45)
672
(26.45)
570
(22.45)
DIMENSIONS in mm (inches)
Dimension A for all models
Cage rating
150 / 300 / 600 lbs
PN 16 .. PN 100
900 / 1500 lbs
2500 lbs
SG range
4 th digit
Dimension A
1.10 - 2.20
L/C/P/F/T
186 (7.32)
0.23 - 0.54
0.55 - 1.09
0.55 - 1.09
J/A/M/D/Q
K/B/N/E/R
K/B/N/E/R
236 (9.29)
186 (7.32)
236 (9.29)
315 (12.40)
Dimensions B and C for external cage models (E83/E84/E85/E86)
Flanged process connections
Flange size
1 1/2"
2"
DN 40
DN 50
Flange rating
150 / 300 / 600 lbs
600 lbs
900 / 1500 lbs
2500 lbs
150 / 300 / 600 lbs
600 lbs
900 / 1500 lbs
2500 lbs
PN 16 .. PN 100
PN 16 .. PN 100
Threaded / Socket weld process connections
Size
1 1/2"
2"
Cage rating
150 / 300 / 600 lbs
900 / 1500 lbs
900 lbs
1500 lbs
2500 lbs
150 / 300 / 600 lbs
900 / 1500 lbs
900 lbs
1500 lbs
2500 lbs
Connection type
Slip on - ANSI RF
Weldneck - ANSI RJ
Weldneck - ANSI RJ
Weldneck - ANSI RJ
Slip on - ANSI RF
Weldneck - ANSI RJ
Weldneck - ANSI RJ
Weldneck - ANSI RJ
EN/DIN
EN/DIN
Connection type
NPT/SW
NPT
SW
SW
NPT/SW
NPT/SW
NPT
SW
SW
NPT/SW
B
Dimensions
180 (7.09)
180 (7.09)
193 (7.60)
235 (9.25)
185 (7.28)
185 (7.28)
214 (8.43)
250 (9.84)
180 (7.09)
185 (7.28)
B
Dimensions
81 (3.19)
81 (3.19)
81 (3.19)
89 (3.50)
102 (4.02)
84 (3.31)
84 (3.31)
84 (3.31)
99 (3.90)
112 (4.41)
C
268 (10.55)
268 (10.55)
283 (11.14)
313 (12.32)
273 (10.75)
273 (10.75)
303 (11.93)
328 (12.91)
268 (10.55)
273 (10.75)
C
_
11
QUALITY ASSURANCE - ISO 9001:2000
THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN,
THE CONSTRUCTION AND THE SERVICE OF CONTROLS.
OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001:2000 AND OUR TOTAL COMPANY IS COMMITTED TO
PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE.
PRODUCT WARRANTY
:2000
ALL EZ MODULEVEL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR FIVE FULL
YEARS (MECHANICAL PARTS) / ONE FULL YEAR (ELECTRONIC PARTS) FROM THE DATE OF ORIGINAL FACTORY SHIPMENT.
IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED
UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN
TRANSPORTATION.
MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION
OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME
MAGNETROL PRODUCTS.
BULLETIN N°:
EFFECTIVE:
SUPERSEDES:
UNDER RESERVE OF MODIFICATIONS
Heikensstraat 6, 9240 Zele, België -Belgique
Tél. +32 (0)52.45.11.11 • Fax. +32 (0)52.45.09.93 • E-Mail: [email protected]
DEUTSCHLAND
Alte Ziegelei 2-4, D-51491 Overath
Tel. +49 (0)2204 / 9536-0 • Fax. +49 (0)2204 / 9536-53 • E-Mail: [email protected]
ITALIA
Via Arese 12, I-20159 Milano
Tel. +39 02 607.22.98 (R.A.) • Fax. +39 02 668.66.52 • E-Mail: [email protected]
INDIA
U.A.E.
UNITED
KINGDOM
C-20 Community Centre, Janakpuri, New Delhi - 110 0058
Tel. +91 (11) 41661840 • Fax +91 (11) 41661843 • E-Mail: [email protected]
DAFZA Office 5EA 722 • PO Box 293671 • Dubai
Tel. +971-4-6091735 • Fax +971-4-6091736 • E-Mail: [email protected]
OUR NEAREST REPRESENTATIVE
www.magnetrol.com
BENELUX
FRANCE
Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL
Tel. +44 (0)1444 871313 • Fax +44 (0)1444 871317 • E-Mail: [email protected]
BE 48-106.7
February 2008
April 2007