Digital E3 Modulevel® Liquid Level Displacer Transmitter D E S C R I P T I O N The Digital E3 Modulevel® is an advanced, intrinsically safe two-wire instrument utilizing simple buoyancy principle to detect and convert liquid level changes into a stable output signal. The linkage between the level sensing element and output electronics provides a simple mechanical design and construction. The vertical in-line design of the transmitter results in low instrument weight and simplified installation. The instrument comes in a variety of configurations and pressure ratings for varied applications. The Digital E3 MODULEVEL has microprocessor-based electronics with 4 –20 mA/HART® or FOUNDATION fieldbus™ output. E3 supports the FDT/DTM standard and a PACTware™ PC software package allows for additional configuration and trending capabilities. T E C H N O L O G Y Changing buoyancy forces caused by liquid level change act upon the spring supported displacer causing vertical motion of the core within a linear variable differential transformer. As the core position changes with liquid level, voltages are induced across the secondary windings of the LVDT. These signals are processed in the electronic circuitry and converted to a useable output signal. The enclosing tube acts as a static isolation barrier between the LVDT and the process media. A P P L I C A T I O N S MEDIA: Liquids or slurries, clean or dirty, light hydrocarbons to heavy acids (SG=0.23 to 2.20) VESSELS: Process & storage, bridles, bypass chambers, interface, sumps & pits up to unit pressure & temperature ratings. CONDITIONS: Most liquid level measurement and control applications including those with varying dielectric, vapors, turbulence, foam, buildup, bubbling or boiling and high fill/empty rates. Also, liquid/liquid interface level measurement or density control. F E A T U R E S • Two-wire, loop-powered, transmitter for level, interface or density measurement • Non-interacting zero and span • No level change needed for configuration; no field calibration necessary. • Specific gravity adjustment without stopping process • Emission and immunity compliance to EN 61326 • Signal damping adjustment • Safety Integrity Level (SIL) value of 2, SFF value of 92.3% • 64-unit multi-drop capability • 4 –20 mA output signal Consult factory for ASME B31.1, ASME B31.3 or NACE construction. • Two-line, 8-character LCD and 3-button keypad • Continuous self-test with 22 mA, 3.6 mA or Hold fault indication fully compliant with NAMUR NE 43 • Comprehensive diagnostics with faults, warnings & status history • HART or FOUNDATION fieldbus digital communications • PACTware PC program using HART communication for advanced configuration and troubleshooting (see bulletin 59-101) • IS, XP and Non-incendive approvals by FM, CSA, ATEX, IEC I N T E R F A C E E3 MODULEVEL is capable of tracking the interface level of two immiscible liquids with different densities. Each unit is custom-made with a displacer specially designed for the user’s application. This allows it to detect the position of a clean interface or an emulsion layer and convert it into a stable 4 –20 mA signal. Contact the factory for assistance in specifying an E3 for interface service. Note that for proper interface detection, the entire displacer must always be immersed in liquid. • Standard output range from 3.8 to 20.5 mA • 11 VDC turn on voltage D E N S I T Y • Maximum loop resistance of 620 ohms at 24 VDC Yet another capability of E3 MODULEVEL is to track the changing density of a liquid over a known density range and convert that into a stable 4–20 mA output signal. As the density of the liquid changes, so does the mass of the liquid displaced by the specially designed displacer. The resulting change in buoyancy force on the displacer causes the movement of the LVDT core necessary to convert the density change to the 4–20 mA signal. • Process temperatures to +850° F (+454° C) for non-steam applications • Level ranges from 14 to 120+ inches (356 to 3048+ mm) • Specific gravity as low as 0.23 • Cast aluminum or stainless steel, TYPE 4X, Cl I Div 1 Groups B, C, D housing • Field wiring in isolated junction box • Head rotatable through 360° PACTware™ P C • Accepted proven LVDT/range spring technology PACTware PC software and the Field Device Tool (FDT) standard take level measurement to a new degree of setup efficiency and user-friendliness. PACTware adds a graphical software interface for increased ease of use. Simply connect your PC through a serial interface to the HART loop and all functionality can be accessed conveniently, and safely. Refer to Magnetrol® PACTware bulletins 59-101 & 59-601 for more information. • Range spring suppresses effects of turbulence to produce stable output signal. • Flanged top mounting or external cage with side/side or side/bottom connections • Special options, materials of construction and custom engineered features available (consult factory). • Spring protector standard • Signal sampling 15 times per second 2 S O F T W A R E S P E C I F I C A T I O N S F U N C T I O N A L System Design Measurement Principle Buoyancy – continuous displacement utilizing a precision range spring Input Measured Variable Level, determined by LVDT core movement affected by Physical Range Up to 120" (300 cm) based on displacer length (consult factory for longer ranges) buoyancy force changes on continuous displacer Output Type 4 to 20 mA with HART Version 6.x 3.8 to 20.5 mA useable (meets NAMUR NE 43) FOUNDATION fieldbus, H1 (31.25 kbits⁄sec), Available blocks AI, PID, RB, TB LAS capable, ITK 5.0 interoperability tested Resolution Analog: 0.01 mA, Display: 0.1%, Level Units: 0.01 inch Loop Resistance (maximum) 620 ohms @ 24 VDC Diagnostic Alarm 3.6, 22 mA or HOLD selectable (meets NAMUR NE 43) Damping Adjustable 0-45 seconds Sampling Rate Transmitter 15 times per second User Interface Keypad 3-button menu-driven data entry and system security Indication 2-line × 8-character LCD display Power Measured at instrument terminals 11 to 36 VDC FOUNDATION fieldbus (Direct Current) HART, 9 to 32 VDC This device provides only Functional Isolation. Current 22.5 mA maximum HART, 17 mA (maximum current draw) FOUNDATION fieldbus This device provides only Functional Isolation. Housing Material Aluminum A356-T6 (<0.20% copper), optional 316 stainless steel Cable Entry 3 Ingress Protection TYPE 4X, IP66 ⁄4" NPT and M20 Chamber Materials Carbon steel 316/316L stainless steel Wetted parts Process connections 316/316L and Inconel® (spring) Tank Top: 3", 4", 6" ANSI Flange Chambered: 11⁄2", 2" NPT, Socketweld, ANSI Flanges Process Conditions Process temperature range ¿ Process pressure range Steam applications: -20° to +800° F (-29° to +427° C) Non-steam applications: -20° to +850° F (-29° to +454° C) ¡ 5150 psig @ +100° F (355 bar @ +38° C) Environment Electronics Operating Temperature -40 to +176° F (-40 to +80° C) Display Function Operating Temperature -5 to +160° F (-20 to +70° C) Storage Temperature -50 to +185° F (-40 to +85° C) Humidity 0-99%, non-condensing Electromagnetic Compatibility Meets CE Requirement: EN 61326 Shock Class ANSI/ISA-S71.03 Class SA1 ¬ Vibration Class ANSI/ISA-S71.03 Class VC2 ¬ Altitude ≤2000 m Pollution Degree 2 ¿ Maximum process temperatures are based on ambient temperatures less than or equal to +120° F (+49° C). Higher ambient temperatures require reduced process temperatures. ¡ Consult factory for low temperature applications down to -330° F (-200° C). ¬ With aluminum housing only. Does not apply to models with 316 SS transmitter housings. 3 S P E C I F I C A T I O N S P E R F O R M A N C E : Reference Conditions L E V E L 1200 Water @ +70° F (+21° C) with 14" displacer, wet calibration Linearity ±0.50% of full span Repeatability ±0.20% of full span Ambient temperature effect Maximum zero shift is 0.017%/°F over ambient temperature range Operating Temp. range: -40° to +176° F (-40° to +80° C) LCD Temp. Range: -5° to +160° F (-20° to +70° C) Hysteresis ±0.20% of full span Response Time <1 second Warm-up Time <5 seconds SIL Suitable for use in SIL 2 environments Linearity ±0.70% of full span Repeatability ±0.40% of full span Maximum zero shift is 0.017%/°F over ambient temperature range 400 200 24 VDC 11 0 10 20 30 Agency Model FM EXX-XXXX EXX-XXXX EXX-XXXX 40 VDC √ The displacer must always be completely immersed in process liquid when the E3 is used in interface or density service. Top mounted models require liquid level to exceed the top of the displacer by 2" at all times to ensure optimal performance. A P P R O V A L S EXX-XXXX 4 620 600 Allowable Loop Resistance vs. Supply Voltage P E R F O R M A N C E : I N T E R F A C E L E V E L & D E N S I T Y √ A G E N C Y 800 Ω 0 with SFF of 92.3% Ambient temperature effect 20.5 mA 1000 Transmitter Codes Digits 8, 9 and 10 x11, x12, x13, x14 x21, x22, x23, x24 x31, x32, x33, x34 x41, x42, x43, x44 x51, x52, x53, x54 x61, x62, x63, x64 x81, x82, x83, x84 x15, x16, x17, x18 x25, x26, x27, x28 x35, x36, x37, x38 x45, x46, x47, x48 x55, x56, x57, x58 x65, x66, x67, x68 x85, x86, x87, x88 x11, x12, x13, x14 x21, x22, x23, x24 x31, x32, x33, x34 x41, x42, x43, x44 x51, x52, x53, x54 x61, x62, x63, x64 x81, x82, x83, x84 x11, x12, x13, x14 x21, x22, x23, x24 x31, x32, x33, x34 x41, x42, x43, x44 x51, x52, x53, x54 x61, x62, x63, x64 x81, x82, x83, x84 Approval Explosion Proof ¿ Class I, Div. 1; Groups B, C, D Type 4X, IP66 Intrinsically Safe ¡ Class I, Div. 1; Groups A, B, C, D Class II, Div. 1; Groups E, F, G Class III, T4 Entity Type 4X, IP66 Non-Incendive Class I, Div. 2; Groups A, B, C, D Class II, Div. 2; Groups E, F, G Class III, Div. 2; T4 Type 4X, IP66 Dust Ignition Proof Class II, Div. 1; Groups E, F, G Class III, T5 Type 4X, IP66 A G E N C Y A P P R O V A L S Transmitter Codes Digits 8, 9 and 10 Agency Model CSA EXX-XXXX x11, x13, x21, x23 x31, x33, x41, x43 x51, x53, x61, x63 x81, x83 EXX-XXXX x15, x17, x25, x27 x35, x37, x45, x47 x55, x57, x65, x67 x85, x87 EXX-XXXX x11, x13, x21, x23 x31, x33, x41, x43 x51, x53, x61, x63 x81, x83 Non-Incendive Class I, Div. 2; Groups A, B, C, D Class II, Div. 2; Groups E, F, G Class III, T4 Type 4X, IP66 EXX-XXXX x1E, x1F, x1G, x1H x2E, x2F, x2G, x2H x3E, x3F, x3G, x3H x4E, x4F, x4G, x4H x5E, x5F, x5G, x5H x6E, x6F, x6G, x6H x8E, x8F, x8G, x8H Flameproof ATEX Ex II 1/2 G Ex d IIC T6 EN 60079-0, EN 60079-1, EN 60079-26 94/9/EC EXX-XXXX x1A, x1B, x1C, x1D x2A, x2B, x2C, x2D x3A, x3B, x3C, x3D x4A, x4B, x4C, x4D x5A, x5B, x5C, x5D x6A, x6B, x6C, x6D x8A, x8B, x8C, x8D EXX-XXXX x1A, x1B, x1C, x1D x2A, x2B, x2C, x2D x3A, x3B, x3C, x3D x4A, x4B, x4C, x4D x5A, x5B, x5C, x5D x6A, x6B, x6C, x6D x8A, x8B, x8C, x8D Non-Sparking ATEX Ex II 3 G Ex ic II T6 EN 60079-0 EN 60079-11 94/9/EC EXX-XXXX x1E, x1F, x1G, x1H x2E, x2F, x2G, x2H x3E, x3F, x3G, x3H Flameproof IECEx Ex d IIC T6 Ga/Gb IEC 60079-0, IEC 60079-1, IEC 60079-26 EXX-XXXX x1A, x1B, x1C, x1D x2A, x2B, x2C, x2D x3A, x3B, x3C, x3D ATEX IEC ¿ On remote electronics housing only, seal is required within 18 inches. ¡ See appropriate Installation & Operating Manual for entity parameters Approval Explosion Proof ¿ Class I, Div. 1; Groups B, C, D Class II, Div. 1; Groups E, F, G Class III, T4 Type 4X, IP66 & IP67 Intrinsically Safe ¡ Class I, Div. 1; Groups A, B, C, D Class II, Div. 1; Groups E, F, G Class III, T4 Entity Type 4X, IP66 Intrinsically Safe ¡ ATEX Ex II 1 G Ex ia IIC T4 EN 60079-0, EN 60079-11, EN 60079-26, EN 60079-27 94/9/EC Intrinsically Safe ¡ IECEx Ex ia IIC T4 Ga IEC 60079-0, IEC 60079-11, IEC 60079-26, IEC 60079-27 These units have been tested to EN 61326 and are in compliance with the EMC Directive 2004/108/EC. for IS installation. 5 D I M E N S I O N A L STANDARD I N C H E S PRESSURE S P E C I F I C A T I O N S MODELS E3A, E3B, E3C, E3D, E3E, E3F ( M M ) 4.02 (102) 4.02 (102) ¾" NPT Dual Conduit Entries ¾" NPT Dual Conduit Entries 4.02 (102) ¾" NPT Dual Conduit Entries A A ANSI standard flange B D C 0.87 (22) 2.81 (71) 3.86 (98) Level range 3.95 (100) H 10.32 (262) J 8.10 (206) 4.04 (103) E 70° Dia. F HT Integral Side/Bottom Mount Fourth Digit Codes A, B, C E3A/E3B Series with Integral Top Mounting Fourth Digit Codes J, K, L Integral Transmitter Head 2.84 502 (72) (128) 3.99 (101) ¾" NPT Dual Conduit Entries K A minus 3.34 (85) 3.85 (98) A minus 3.34 (85) D Level range Level range G G E F 1" NPT drain (plug not provided) Remote Side/Side Mount Fourth Digit Codes A, B, C 5.31 (135) 45° 6.25 (159) D 4.02 (102) 3.96 (101) 8.73 (222) 15.95 (405) 6 6.28 (159) 5.42 (138) 6.48 (165) 2.39 (61) Up to 75' (23 m) of connecting cable part number 037-3226-0XX or 037-3227-0XX, run in conduit. Last 2 digits in part number are cable length in feet. Cable must be ordered separately. E F 1" NPT drain (plug not provided) Remote Side/Side Mount Fourth Digit Codes A, B, C 15.95 (405) D I M E N S I O N A L I N C H E S 9th Digit ( M M ) Cage Press. Rating Process Conn. Size Spring S.G. Range 0.23 – 0.54 11⁄2" 0.55 – 1.09 1.10 – 2.20 150#, 300# & 600# ANSI 1, 2, 3, 4, 5, 6 S P E C I F I C A T I O N S 0.23 – 0.54 2" 0.55 – 1.09 1.10 – 2.20 11⁄2" 0.55 – 1.09 2" 0.55 – 1.09 11⁄2" 0.55 – 1.09 2" 0.55 – 1.09 11⁄2" 0.55 – 1.09 2" 0.55 – 1.09 11⁄2" 0.55 – 1.09 2" 0.55 – 1.09 11⁄2" 0.55 – 1.09 2" 0.55 – 1.09 11⁄2" 0.55 – 1.09 2" 0.55 – 1.09 11⁄2" 0.55 – 1.09 2" 0.55 – 1.09 900# ANSI 1500# ANSI 2500# ANSI 150#, 300# & 600# 900# 8 1500# 2500# Dimension B C D E F G H J K 6.75 (171) 4.75 (121) 4.75 (121) 6.75 (171) 4.75 (121) 4.75 (121) 6.75 (171) 6.75 (171) 6.75 (171) 6.75 (171) 6.75 (171) 6.75 (171) 8.25 (210) 8.25 (210) 8.25 (210) 8.25 (210) 8.25 (210) 8.25 (210) 8.25 (210) 8.25 (210) 9.31 (236) 7.31 (186) 7.31 (186) 9.31 (236) 7.31 (186) 7.31 (186) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 7.31 (186) 7.31 (186) 9.31 (236) 7.31 (186) 7.31 (186) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 9.31 (236) 3.19 (81) 3.19 (81) 3.19 (81) 3.31 (84) 3.31 (84) 3.31 (84) 3.19 (81) 3.31 (84) 3.19 (81) 3.31 (84) 4.00 (102) 4.38 (111) 3.19 (81) 3.31 (84) 3.19 (81) 3.31 (84) 3.19 (81) 3.31 (84) 4.00 (102) 4.38 (111) 7.00 (178) 7.00 (178) 7.00 (178) 7.13 (181) 7.13 (181) 7.13 (181) 7.00 (178) 7.13 (181) 7.00 (178) 8.13 (207) 9.00 (229) 9.81 (249) 7.00 (178) 7.13 (181) 7.00 (178) 7.13 (181) 7.00 (178) 8.13 (207) 9.00 (229) 9.81 (249) 3.00 (76) 3.00 (76) 3.00 (76) 3.00 (76) 3.00 (76) 3.00 (76) 3.00 (76) 3.00 (76) 3.44 (87) 3.44 (87) 3.44 (87) 3.44 (87) 3.00 (76) 3.00 (76) 3.00 (76) 3.00 (76) 3.44 (87) 3.44 (87) 3.44 (87) 3.44 (87) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.44 + range (87 + range) 3.44 + range (87 + range) 3.44 + range (87 + range) 3.44 + range (87 + range) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.00 + range (76 + range) 3.44 + range (87 + range) 3.44 + range (87 + range) 3.44 + range (87 + range) 3.44 + range (87 + range) 5.43 (138) 5.43 (138) 5.43 (138) 5.43 (138) 5.43 (138) 5.43 (138) 5.43 (138) 5.43 (138) 6.43 (163) 7.43 (189) 10.21 (259) 11.08 (281) 5.43 (138) 5.43 (138) 5.43 (138) 5.43 (138) 6.43 (163) 7.43 (189) 1021 (259) 11.08 (281) 10.32 (262) 10.32 (262) 10.32 (262) 10.32 (262) 10.32 (262) 10.32 (262) 10.32 (262) 10.32 (262) 10.32 (262) 10.32 (262) 10.32 (262) 10.32 (262) 11.60 (295) 11.60 (295) 11.60 (295) 11.60 (295) 11.60 (295) 11.60 (295) 11.60 (295) 11.60 (295) “A” Dimension Cage Press. Rating 150# ANSI 300# ANSI 600# ANSI 900# ANSI 1500# ANSI 2500# ANSI Fourth Digit of Model Number Head Flange Size A, B, C D, E, F J, K, L M, N, P 3" 16.97 (431) 24.97 (634) 12.97 (329) 20.97 (533) 4" 16.97 (431) 24.97 (634) 12.97 (329) 20.97 (533) 6" 17.03 (433) 25.03 (636) 13.03 (331) 21.03 (534) 3" 17.16 (436) 25.16 (639) 13.16 (334) 21.16 (537) 4" 17.28 (439) 25.28 (642) 13.28 (337) 21.28 (541) 6" 17.47 (444) 25.47 (647) 13.47 (342) 21.47 (545) 3" 17.53 (445) 25.53 (648) 13.53 (344) 21.53 (547) 4" 17.78 (452) 25.78 (655) 13.78 (350) 21.78 (553) 6" 18.16 (461) 26.16 (664) 14.16 (360) 22.16 (563) 3" 17.78 (452) 25.78 (655) 13.78 (350) 21.78 (553) 4" 18.03 (458) 26.03 (661) 14.03 (356) 22.03 (560) 6" 18.47 (469) 26.47 (672) 14.47 (368) 22.47 (571) 3" 18.16 (461) 26.16 (664) 14.16 (360) 22.16 (563) 4" 18.41 (468) 26.41 (671) 14.41 (366) 22.41 (569) 6" 19.53 (496) 27.53 (699) 15.53 (394) 23.53 (598) 4" 19.28 (490) 27.28 (693) 15.28 (388) 23.28 (591) 6" 20.53 (521) 28.53 (725) 16.53 (420) 24.53 (623) 7 N O N - S T E A M M O D E L S E R V I C E N U M B E R Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). DESIGN TYPE E3 Standard Construction Electronic MODULEVEL MOUNTING AND CHAMBER MATERIALS Flanged top ¿ steel 316 SS A B Cage side/bottom steel 316 SS ¡ C D Cage side/side steel 316 SS ¡ E F ¿ Adjustable 8-foot hanger cable, part number 32-3110-001, required when distance from flange face to top of displacer must be greater than 7.31". ¡ Bolting material is alloy steel. SPECIFIC GRAVITY AND PROCESS TEMPERATURE Integral or Remote 1, 4 & 8 ¬ 3, 6 & 8 ¬ 1&4 1&4 1&4 +300° F +400° F +450° F +850° F +750° F (+150° C) (+200° C) (+230° C) (+454° C) (+399° C) J A M D M K B N E N L C P F P ¬ 9th Digit=8 only good with 0.55–1.09 SG. Transmitter Mounting Use with Mounting/Temp. codes (9th Digit) maximum process temperature 0.23 – 0.54 specific gravity (up to 600 lbs) 0.55 – 1.09 specific gravity (all pressures) 1.10 – 2.20 specific gravity (up to 600 lbs) PROCESS CONNECTION SIZE & TYPE External Cage 11⁄2" 2" A 3" Top Mount 4" 6" Type E n/a n/a n/a R F n/a n/a n/a SW P Q G H K Flange NPT CHAMBER PRESSURE CLASS 150# RF 3 300# RF 4 ANSI Flange rating 600# RF 900# RF 1500# RF √ 2500# RF √ƒ≈ 5 6 7 8 √ Pressure rating limited by enclosing tube to 5150 psi @ +100° F. ƒ For stainless steel construction on 1500# and 2500# models, consult factory. ≈ Models E3A and E3B with 2500# construction must have a mounting flange 4" or greater. LEVEL RANGE All Pressures / 9th Digit = 8 14 32 48 60 356 813 1219 1524 A B C D 72 1829 E 600# and below 84 96 108 2134 2438 2743 F G H 120 3048 I TRANSMITTER – ELECTRONICS (see opposite page) E 8 3 Inches mm Code N O N - S T E A M M O D E L S E R V I C E N U M B E R OUTPUT/SIL RATING H F 4-20 mA/HART, SIL 2 FOUNDATION fieldbus Digital Communications (English only) MOUNTING/TEMPERATURE Integral Mount Maximum Process Temperature +550° F (+290° C) 1 +551° to +600° F (+291° to +315° C) 3 Remote Mount ∆ Maximum Process Temperature 4 6 8 +550° F (+290° C) +551° to +600° F (+291° to +315° C) +601° to +850° F (+316° to +454° C) Use with Specific Gravity and Process Temperature codes (4th Digit): J, K, L, A, B, C, M, N, P, D, E, F M, N, P Use with Specific Gravity and Process Temperature codes: J, K, L, A, B, C, M, N, P, D, E, F M, N, P E, N ∆ Cable for remote mounting transmitter is 037-3226-xxx up to +400° F (+204° C) and 037-3227-xxx (Belden 88777) above +400° F (+204° C) where -xxx is the length in feet from 10 (-010) to 400 (-400) feet. HOUSING MATERIAL/CONDUIT ENTRY/APPROVAL 1 2 3 4 5 6 7 8 A B C D E F G H Cast aluminum, FM/CSA XP, 3⁄4" NPT Cast aluminum, FM XP, M20 Cast stainless steel, FM/CSA XP, 3⁄4" NPT Cast stainless steel, FM XP, M20 Cast aluminum, FM/CSA IS, 3⁄4" NPT Cast aluminum, FM IS, M20 Cast stainless steel, FM/CSA IS, 3⁄4" NPT Cast stainless steel, FM IS, M20 Cast aluminum, ATEX/IEC IS, 3⁄4" NPT Cast aluminum, ATEX/IEC IS, M20 Cast stainless steel, ATEX/IEC IS, 3⁄4" NPT Cast stainless steel, ATEX/IEC IS, M20 Cast aluminum, ATEX/IEC XP, 3⁄4" NPT Cast aluminum, ATEX/IEC XP, M20 Cast stainless steel, ATEX/IEC XP, 3⁄4" NPT Cast stainless steel, ATEX/IEC XP, M20 E3X-XXXX (see previous page) E 3 9 S T E A M M O D E L S E R V I C E N U M B E R DESIGN TYPE E3 Standard Construction Electronic MODULEVEL MOUNTING AND CHAMBER MATERIALS Flanged top ¿ steel 316 SS A B Cage side/bottom steel 316 SS ¡ C D Cage side/side steel 316 SS ¡ E F ¿ Adjustable 8-foot hanger cable, part number 32-3110-001, required when distance from flange face to top of displacer must be greater than 7.31". ¡ Bolting material is alloy steel. SPECIFIC GRAVITY AND PROCESS TEMPERATURE Integral or Integral Remote Remote 1&4 2 5 +300° F +400° F +400° F (+150° C) (+200° C) (+200° C) K B Integral or Remote 2&5 +450° F (+230° C) K Integral or Remote Transmitter Mounting Remote 3&8 6&8 Use with Mounting/Temp. codes (9th Digit) +800° F +700° F maximum process temperature (+427° C) (+371° C) N E N 0.55 - 1.09 specific gravity (all pressures) PROCESS CONNECTION SIZE & TYPE External Cage 11⁄2" 2" A R P E F Q 3" n/a n/a G Top Mount 4" 6" n/a n/a n/a n/a H K Type NPT SW Flange CHAMBER PRESSURE CLASS 150# RF 3 300# RF 4 ANSI Flange rating 600# RF 900# RF 1500# RF √ 2500# RF ¬√ƒ 5 6 7 8 ¬ Pressure rating limited by enclosing tube to 5150 psi @ +100° F. √ For stainless steel construction on 1500# and 2500# models, consult factory. ƒ Models E3A and E3B with 2500# construction must have a mounting flange 4" or greater. LEVEL RANGE All Pressures / 9th Digit = 8 14 32 48 60 356 813 1219 1524 A B C D 72 1829 E 600# and below 84 96 108 2134 2438 2743 F G H 120 3048 I TRANSMITTER – ELECTRONICS (see opposite page) E 10 3 Inches mm Code S T E A M M O D E L S E R V I C E N U M B E R OUTPUT/SIL RATING H F 4-20 mA/HART, SIL 2 FOUNDATION fieldbus Digital Communications (English only) MOUNTING/TEMPERATURE Integral Mount Maximum Process Temperature +300° F (+150° C) 1 +301° to +450° F (+151° to +230° C) 2 +451° to +500° F (+231° to +260° C) 3 Remote Mount ≈ Maximum Process Temperature 4 5 6 8 +300° F (+150° C) +301° to +450° F (+151° to +230° C) +451° to +500° F (+231° to +260° C) +501° to +800° F (+261° to +427° C) Use with Specific Gravity and Process Temperature codes (4th Digit): K B, N E Use with Specific Gravity and Process Temperature codes (4th Digit): K B, K, N E, N E, N ∆ ≈ Cable for remote mounting transmitter is 037-3226-xxx up to +400° F (+204° C) and 037-3227-xxx (Belden 88777) above +400° F (+204° C) where -xxx is the length in feet from 10 (-010) to 400 (-400) feet. ∆ 4th digit N with 9th digit 8 has a maximum temperature of +700° F (+371° C). HOUSING MATERIAL/CONDUIT ENTRY/APPROVAL E3X-XXXX (see previous page) E 1 Cast aluminum, FM/CSA XP, 3⁄4" NPT 2 Cast aluminum, FM XP, M20 3 Cast stainless steel, FM/CSA XP, 3⁄4" NPT 4 Cast stainless steel, FM XP, M20 5 Cast aluminum, FM/CSA IS, 3⁄4" NPT 6 Cast aluminum, FM IS, M20 7 Cast stainless steel, FM/CSA IS, 3⁄4" NPT 8 Cast stainless steel, FM IS, M20 A Cast aluminum, ATEX/IEC IS, 3⁄4" NPT B Cast aluminum, ATEX/IEC IS, M20 C Cast stainless steel, ATEX/IEC IS, 3⁄4" NPT D Cast stainless steel, ATEX/IEC IS, M20 E Cast aluminum, ATEX/IEC XP, 3⁄4" NPT F Cast aluminum, ATEX/IEC XP, M20 G Cast stainless steel, ATEX/IEC XP, 3⁄4" NPT H Cast stainless steel, ATEX/IEC XP, M20 3 11 Q U A L I T Y The quality assurance system in place at Magnetrol® guarantees the highest level of quality throughout the company. MAGNETROL is committed to providing full customer satisfaction both in quality products and quality service. The MAGNETROL quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. Several Electronic MODULEVEL Displacer Transmitters are available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). E S P Expedite Ship Plan Models covered by ESP service are color coded in the selection data charts. ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. W A R R A N T Y All MAGNETROL electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, MAGNETROL will repair or replace the control at no cost to the purchaser (or owner) other than transportation. MAGNETROL shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some MAGNETROL products. For additional information, see Instruction Manual 48-635 or 48-640. 705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000 • Fax 630-969-9489 [email protected] • www.magnetrol.com Copyright © 2016 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. Magnetrol, Magnetrol logotype and Modulevel are registered trademarks of Magnetrol International, Incorporated. BULLETIN: 48-135.7 EFFECTIVE: February 2016 SUPERSEDES: June 2015